• 제목/요약/키워드: CET(capacitive electric transfer)

검색결과 3건 처리시간 0.017초

개인용 고주파 전기자극기의 주파수 가변 설계 및 출력 특성의 분석 (Analysis of Output Characteristics and Frequency Variation Design for Personal High Frequency Electrical Stimulation Medical Devices)

  • 장경욱;임지현;백승명;손진근
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.25-30
    • /
    • 2016
  • In this paper, personal electrical stimulation medcial devices using bioelectrical stimulating was developed. Therapy effect of RET(resistive electric transfer) was more effective than CET(capacitive electric transfer), but CET was adopted because of safety issue. Then, the optimum parameters that may be effective in thin skin or facial wrinkles was set. For example, the frequency of the pulse voltage for stimulation is 1.8[MHz], burst frequency is 7[kHz] or 400[Hz], the development of devices was to have ON/OFF control and frequency control. When burst frequency was adjusted 7[kHz], heat was generated in the electrode. The case of 400[Hz] the heat was little generated. The microcontroller ATmega128-based experimental results show that the proposed personal high frequency electrical stimulation devices can be applied to medical equipment using therapy effect successfully.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

심부투열용 고주파 치료기의 제작과 RET 전극조건에 따른 온도 분포 특성 (Fabrication of high-frequency therapy device for deep part and temperature distribution characteristic according to electrode condition of RET)

  • 정재원;김병주;김기선
    • 공학기술논문지
    • /
    • 제11권4호
    • /
    • pp.267-271
    • /
    • 2018
  • A high-frequency therapy device with improved output by modifying a high-frequency stimulator was fabricated. The details of the design include generating part design, high-frequency transformer design, large output FET installation, DC voltage input part design and gate input driver design. Based on the real test using the pork meat, the temperature distributions according to the current electric transfer method, penetration depth, electrode diameter size were measured. In the CET method, the penetration depth was 0.5 cm and in the RET method, the penetration depth was 20 cm or more. In addition, it was confirmed that the temperature rise according to the penetration depth in the RET system was substantially constant, and the temperature rise was remarkable as the electrode diameter was small. As a result, it has been confirmed that the high frequency therapy device is highly affected by various conditions of the electrode.