• 제목/요약/키워드: CEC efficiency

검색결과 33건 처리시간 0.027초

Immobilization of Styrene-acrylamide Co-polymer on Either Silica Particles or Inner Surface of Silica Capillary for the Separation of D-Glucose Anomers

  • Ali, Faiz;Kim, Yune Sung;Cheong, Won Jo
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.539-545
    • /
    • 2014
  • Styrene-acrylamide co-polymer was immobilized on porous partially sub-$2{\mu}m$ silica monolith particles and inner surface of fused silica capillary ($50{\mu}m$ ID and 28 cm length) to result in ${\mu}LC$ and CEC stationary phases, respectively, for separation of anomeric D-glucose derivatives. Reversed addition-fragmentation transfer (RAFT) polymerization was incorporated to induce surface polymerization. Acrylamide was employed to incorporate amide-functionality in the stationary phase. The resultant ${\mu}LC$ and CEC stationary phases were able to separate isomers of D-glucose derivatives with high selectivity and efficiency. The mobile phase of 75/25 (v/v) acetonitrile (ACN)/water with 0.1% TFA, was used for HPLC with a packed column (1 mm ID, 300 mm length). The effects of pH and ACN composition on anomeric separation of D-glucose in CEC have been examined. A mobile phase of 85/15 (v/v) ACN/30 mM sodium acetate pH 6.7 was found the optimized mobile phase for CEC. The CEC stationary phase also gave good separation of other saccharides such as maltotriose and Dextran 1500 (MW~1500) with good separation efficiency (number of theoretical plates ~300,000/m).

건축설비의 에너지보존 계획

  • 명현국
    • 대한설비공학회지:설비저널
    • /
    • 제29권9호
    • /
    • pp.56-62
    • /
    • 2000
  • 1997년 12월 일본 교토에서 개최된 COP3를 계기로 1999년 3월 에너지보존법이 대폭적으로 개정 및 강화되어졌다. 지구온난화의 주된 원인이 되는 이산화탄소는 에너지와 밀접한 관계를 가지고 있으므로, 에너지보존·자원보존의 추진은 지구온난화 대책의 추진과 동등한 의미를 가지고 있다고 하여도 과언이 아니다. 여기서는 건축설비계획의 관점에서 에너지보존법 개정의 요점과 그 대응책에 관해서 개요를 소개하였다.

  • PDF

태양광 인버터의 한국형 전력변환 효율에 관한 연구 (A Study of Korean Efficiency of PV PCS)

  • 김정환;유병규;소정훈;이기옥;유권종
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.356-360
    • /
    • 2009
  • Recent global environmental pollution and contamination and depletion of limited fossil energy prices surge as an energy source to replace it depending on wind, fuel cells and solar power and other renewable and pollution free renewable energy is of interest in increase. The photovoltaic systems are pollution-free, unlimited energy source, and easy to install because it is rated as the most valuable renewable energy sector and the prevalence is spreading throughout the world. Photovoltaic systems at one end of the stable development of the role that solar power inverter applications can be the most important. No matter how much power the solar arrays, even if the inverter output in the normally if he's no use. These photovoltaic inverters to evaluate the performance of the inverter efficiency measures that can be called directly. This way of measuring the efficiency of solar inverters in Europe efficiency and CEC efficiency is currently being used. In this paper, until now about how to measure the efficiency of solar power inverter technology and the new Korean Meteorological Solar Insolation data analysis to derive weights based on this inverter efficiency for Korea is to offer.

  • PDF

중금속 흡착을 위한 원위치 피복소재로서 천연제올라이트의 양이온교환용량에 따른 적용성 평가 (Applicability of Natural Zeolite with Different Cation Exchange Capacity as In-situ Capping Materials for Adsorbing Heavy Metals)

  • 강구;신원호;홍성구;김영기;박성직
    • 대한환경공학회지
    • /
    • 제39권2호
    • /
    • pp.51-58
    • /
    • 2017
  • 본 연구에서는 오염퇴적물의 원위치 피복을 위한 소재의 적용성 평가를 위해 양이온교환용량이 다른 제올라이트의 중금속 흡착특성을 평가하였다. 실험을 위해 양이온교환용량이 높은 제올라이트(HCzeo, 163.74 cmol/kg), 중간 값의 양이온교환용량의 제올라이트(MCzeo, 127.20 cmol/kg), 양이온교환용량이 낮은 제올라이트(LCzeo, 70.62 cmol/kg)를 사용하였다. 비표면적을 측정한 결과 HCzeo ($59.43m^2/g$) > MCzeo ($52.10m^2/g$) > LCzeo ($10.12m^2/g$)순으로 높은 결과를 나타내었다. 광물학적 조성 분석을 위해 XRD 측정결과 LCzeo는 quartz와 albite로 구성되었고 MCzeo와 HCzeo의 구성광물은 quartz, albite와 더불어 clinoptilolite, heulandite, mordenite도 측정되었다. HCzeo, MCzeo, LCzeo를 이용한 Cd, Cu, Ni, Zn의 동역학적 흡착실험 결과 실험 6시간대에 흡착 평형에 도달하였다. 평형흡착실험 결과 Cd과 Zn의 흡착은 제올라이트의 양이온교환용량에 따라 증가하였지만 Cu와 Ni의 흡착은 양이온교환용량에 따라 증가하는 경향을 보이지 않았다. 이에 따라 오염퇴적물의 원위치 피복적용에 있어 Cd과 Zn으로 오염된 지역은 양이온교환용량이 높은 제올라이트의 피복적용이 효과적이지만 Cu와 Ni로 오염된 지역의 경우 가격이 저렴한 양이온교환용량이 낮은 제올라이트를 적용하여도 무방할 것으로 판단된다.

Chemical Treatment of Low-level Radioactive Liquid Wastes(II) (The Determination of Cation Exchange Capacity on various Clay Minerals)

  • Lee, Sang-Hoon;Sung, Nak-Jun
    • Nuclear Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.75-81
    • /
    • 1977
  • 원자력 발전소에서 나오는 방사성 핵종이 clay 속에 고정되는 반응기구를 분석하기 위해서 clay의 양이온 교환능을 Sawhney 방법으로 측정했다. Clinoptilolite, vermiculite 및 sodalite들의 PH dependent CEC를 측정한 결과 총 양이온 교환능의 약 70% 정도가 영구 고정되어진다고 생각되는 neutral salt CEC에 의해 일어나고 나머지는 가역과정인 clay 속의 유기물질과 다른 급속(Al, Mg)의 치환에 의해서 일어난다는 결론을 얻었으며, pH 9 이상에서 clay에 의한 방사성 핵종의 제거는 이온 교환 기구에 의한 고정보다 오히려 중금속 이온의 침전에 의해서 더 많이 일어난다는 것도 밝혀냈다. 그리고 연속 치환에 의해서 처리된 Na-clay는 방사성 핵종제거에 상당히 향상된 제거 효율을 나타내고 있다.

  • PDF

NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY (NIRS) IN PHYTOCHEMISTRY

  • Huck, C.W.;W.Guggenbichler;Bonn, G.K.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3114-3114
    • /
    • 2001
  • During the last years phytochemistry and phytopharmaceutical applications have developed rapidly and so there exists a high demand for faster and more efficient analysis techniques. Therefore we have established a near infrared transflectance spectroscopy (NIRS) method that allows a qualitative and quantitative determination of new polyphenolic pharmacological active leading compounds within a few seconds. As the NIR spectrometer has to be calibrated the compound of interest has at first to be characterized by using one or other a combination of chromatographic or electrophoretic separation techniques such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC), capillary electrophoresis (CE), gas chromatography (GC) and capillary electrochromatography (CEC). Both structural elucidation and quantitative analysis of the phenolic compound is possible by direct coupling of the mentioned separation methods with a mass spectrometer (GC-MS, LC-MS/MS, CE-MS, CEC-MS) and a NMR spectrometer (LC-NMR). Furthermore the compound has to be isolated (NPLC, MPLC, prep. TLC, prep. HPLC) and its structure elucidated by spectroscopic techniques (UV, IR, HR-MS, NMR) and chemical synthesis. After that HPLC can be used to provide the reference data for the calibration step of the near infrared spectrometer. The NIRS calibration step is time consuming, which is compensated by short analysis times. After validation of the established NIRS method it is possible to determine the polyphenolic compound within seconds which allows to raise the efficiency in quality control and to reduce costs especially in the phytopharmaceutical industry.

  • PDF

여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가 (Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties)

  • 김태균;조강우;송경근;윤민혁;안규홍;홍승관
    • 대한환경공학회지
    • /
    • 제31권7호
    • /
    • pp.483-490
    • /
    • 2009
  • 본 연구의 목적은 도시지역 강우유출수 내에 존재하는 다양한 오염물질에 대한 여과장치의 제거 효율을 평가하고 여재의 특성에 따른 설계인자를 도출하는데 있다. 비점오염물질 제어기술로서 여과 장치 내에 충전될 여재의 선정은 여과장치의 수명과 크기를 결정하는 중요한 요소이다. 본 연구에서는 컬럼운전을 수행함으로써 펄라이트와 합성여재의 강우유출수 내에 존재하는 오염물질에 대한 제거능을 조사하였다. 각 여재의 양이온교환능력 (CEC) 및 제타전위 등 여재의 표면특성을 분석한 결과 펄라이트가 양 이온계 오염물질의 흡착에 있어서는 더 우수한 것으로 나타났다. 또한 컬럼 운전 수행 결과 입자성 오염물질인 $TCOD_{Cr}$와 탁도는 초기 2.5분의 접촉시간만 가지고도 대부분의 제거가 가능한 것을 확인할 수 있었다. 한편 수리학적 특성에 있어 EBCT (empty bed contact time) 2.5분의 시점에서 살펴보았을 때 폐색이 발생한 시점은 펄라이트는 630분, 합성여재에서는 810분으로 동일 조건에서 합성여재의 운전 수명이 더 긴 것으로 나타났다. 용존성 오염물질인 $SCOD_{Cr}$에 대하여서는 두 여재 모두 뚜렷한 제거 특성이 보이지 않았으며 이 결과는 흡착에 필요한 접촉시간이 확보되지 못한 것으로 판단된다. 마지막으로 여재의 표면 특성인 양이온 교환능력과 중금속 제거효율 사이의 상관관계는 찾아볼 수 없어 대부분 입자에 포획된 상태로 제거됨을 알 수 있었다. 본 연구의 결과는 향후 도시지역 강우유출수 처리를 위한 여과장치 설계 및 적정 여재 선정에 있어 중요한 자료로 활용될 수 있을 것이다.

암모늄으로 오염된 비위생 매립지 주변지반의 지하수 정화를 위한 반응벽체내 물질 연구 (Feasibility Study on Reactive Material in Permeable Reactive Barriers Against Contaminated Groundwater with Ammonium from Unsanitary Landfill)

  • 이승학;박준범
    • 한국지반공학회논문집
    • /
    • 제20권1호
    • /
    • pp.29-36
    • /
    • 2004
  • 암모늄으로 오염된 불량 매립지의 주변지반 지하수를 정화함에 있어 반응벽체를 적용할 경우, 고려해야 할 주요 설계인자를 평가하기 위해 회분식 실험, 투수시험, 주상실험을 수행하였다. 반응물질로는 높은 양이온교환능(CEC)를 가지는, 천연 제올라이트의 일종인 Clinoptilolite를 사용하였다. 회분식 실험의 경우, 암모늄 오염액의 초기농도와 Clinoptilolite 입자크기를 변화시키며 Clinoptilolite의 암모늄에 대한 제거율을 평가하였다. 암모늄의 초기농도가 80ppm으로 고농도인 경우를 제외하고는 단위 량의 Clinoptilolite로 약 80% 암모늄을 제거할 수 있었다. Clinoptilolite의 입자크기에 의한 영향은 뚜렷하지 않았다. 투수시험은 Clinoptilolite와 주문진사를 무게비 20 : 80으로 혼합한 후 시편을 성형하여 수행하였다. 투수시험에는 연성벽체 투수기를 사용하였다. 시험결과, 세척된 0.42∼0.85mm의 크기를 가지는 Clinoptilolite를 포함하는 시편이, 약 $10^{-3}$cm/s의 투수계수로 가장 높은 값을 보였다. 주상실험에서는 실제 매립지 침출수를 이용해, 유동 상태에서 암모늄 이온을 포함한 침출수와 Clinoptilolite 혼합토의 반응성을 검토하였다. 본 연구를 통해 Clinoptilolite는 암모늄을 정화하고자 하는 반응벽체에 적용 가능한 반응물질로 판단되었다.

관수주기와 상토조성이 자생 골고사리(Asplenium scolopendrium)의 생육과 생리에 미치는 영향 (Effects of Irrigation Times and Soil Media on the Growth and Physiological Characteristics of Native Fern Asplenium scolopendrium)

  • 주진희;방광자
    • 한국조경학회지
    • /
    • 제32권6호
    • /
    • pp.109-116
    • /
    • 2005
  • This study was conducted to examine the growth and physiological characteristics of Asplenium scolopendrium native fern as affected by irrigation times and soil media as an environment modeled on habitate where was sunken-condition. 1. Light intensity was lower in sunken than in non-sunken, but air humidity was higher in sunken about $2040\%$. Soil moisture content was higher with the leaf mold in sunken irrigating 2 times/week. The results of chemical analysis of medium showed that EC, pH, organic matter content, total nitrogen, CEC, Exch-Ca, Exch-Mg and Exch-K were higher with leaf mold than sud: leafmold and field soil: sud: leaf mold. 2. In the case of irrigation 2 times/week Asplenium scolopendrium grew well sunken more than non-sunken. As non-sunken condition similar with, 7 times/week irrigation, plant height, frond width, frond length and stipe length increased. In case of soil media, growth of Asplenium scolopendrium was better with leaf mold than that of sand: leafmold or field soil: sand: leaf mold. 3. In the case of irrigation 2 times/week photosynthetic rate, $CO_2$ absorption rate and water efficiency were higher with non-sunken than that of sunken, expect of stomatal conduction, $CO_2$ use efficiency. The physiological characteristics of Asplenium scolopendrium were highest in non-sunken irrigating 7 times/week In case of soil media, physiological activity was higher with leaf mold than sand: leafmold or field soil: sand: leaf mold.