• Title/Summary/Keyword: CCD - characteristics

Search Result 292, Processing Time 0.024 seconds

CCD Pixel Correction Table Generation for MSC

  • Kim Young Sun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Paik Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.471-474
    • /
    • 2004
  • Not all CCD pixels generate uniform value for the uniform radiance due to the different process of manufacture and each pixel characteristics. And the image data compression is essential in the real time image transmission because of the high line rate and the limited RF bandwidth. This pixel's nonuniformity and the loss compression make CCD pixel correction necessary in on-orbit condition. In the MSC system, the NUC unit, which is a part of MSC PMU, is charge of the correction for CCD each pixel. The correction is performed with the gain and the offset table for the each pixel and the each TDI mode. These correction tables are generated and programmed in the PMU Flash memory through the various image data tests at the ground test. Besides, they can be uploaded from ground station after onorbit calibration. This paper describes the principle of the table generation and the test way of the non-uniformity after NUC

  • PDF

Study on Comparing the Performance of Linear CCD sensor with PSD sensor for Distance Measurement (변위측정을 위한 선형 CCD 센서와 PSD 센서의 성능 비교에 관한 연구)

  • Shin, Myung-Kwan;Park, Kyi-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2167-2169
    • /
    • 2004
  • The main concern for a displacement measurement is the performance of a sensor such as speed, resolution, accuracy and so on. The mainly used sensors are a linear CCD(charge coupled device) and a PSD(position sensitive detection) as a non-contact type. The output value of a linear CCD is so sensitive to a temperature change that it needs a cooling device. Additionally, because of its structural problem, there are some limits in resolution and speed, and it needs a complex image processing algorithm. Also, PSD has some disadvantages like sensitivity to environmental lights and nonlinearities. Like this, a linear CCD and PSD have their own characteristics and if we know them well, we can choose the one of the two sensors properly in some applications according to purposes. In this paper, I performed which one is superior to the other among the two sensors in terms of accuracy, resolution, measurement speed, signal to noise ratio.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Performance Characteristics for the Variation of Altitude and Tilt Angle in the Satellite Imager Using Time Delay and Integration(TDI) (Time Delay and Integration(TDI)을 사용하는 위성 영상 기기의 고도 및 촬영각 변화에 대한 성능 특성)

  • 조영민
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.2
    • /
    • pp.91-96
    • /
    • 2002
  • The performance characteristics of a satellite imager using a Time Delay and Integration(TDI) Charge Coupled Device (CCD) with fixed integration time is investigated for the variation of satellite altitude and tilt angle. In consequence of the investigation TDI synchronization using tilt imaging is proposed as a solution to compensate geometric performance degradation due to altitude decrease. The tilt angle optimized for the TDI synchronization at decreased altitude is presented. This result can be used for a TDI CCD imager with variable integration time in a certain range as well.

Measurement of Tool Wear using Machine Vision in Flat End-mill (머신비젼을 이용한 평 엔드밀 공구의 마모측정)

  • Kim, Tae-Young;Kim, Eung-Nam;Kim, Min-Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.53-59
    • /
    • 2011
  • End milling is available for machining the various shape of products and has been widely applied in many manufacturing industries. The quality of products depends on a machine tool performance and machining conditions. Recognition characteristics of the cutting condition is becoming a critical requirement for improving the utilization and flexibility of present-day CNC machine tools. The measurement of tool wear would be performed by coordinate-measuring machine(CMM). However, the usage of CMM requires much time and cost. In order to overcome the difficulties, on-line measurement(OLM) system was applied for a tool wear measurement. This study shows a reliable technique for the reduction of machining error components by developing a system using a CCD camera and machine vision to be able to precisely measure the size of tool wear in flat end milling for CNC machining. The CCD camera and machine vision attached to a CNC machine can determine tool wear quickly and easily.

Edge model based digital still image enlargement considering low-resolution CCD device characteristics (저해상도 CCD 소자 특성을 고려한 경계 모델 기반 디지털 정지 영상 확대)

  • 전준근;최영호;김한주;박규태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2345-2354
    • /
    • 1998
  • There have been many researches to yield higher resolution image quality from the low resolution CCD device. The resolution of it is primary factor for the image quality of digital still camera and in manufacturing price. IN this paper, image enlargement algorithm, which reduces blocking effect of enlarged low resolution image and minimizes ringing and blur effect occurring around edge in linear interpolation, is proposed. This algorithm is composed of gaussian low pass filter which eliminates aliasing, least square spline interpolation and non-linear interpolation based on step edge model.

  • PDF

CCD Signal Processing for Optimal Non-Uniformity Correction

  • Kong, Jong-Pil;Lee, Song-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.645-652
    • /
    • 2010
  • The performance of the payload Electro-Optical System (EOS) in satellite system is affected by various factors, such as optics design, camera electronics design, and the characteristics of the CCD (Charge Coupled Device) used, etc. Of these factors, the camera electronics design is somewhat unique in that its operational parameters can be adjusted even after the satellite launch. In this paper, the effect of video gain on the non-uniformity correction performance is addressed. And a new optimal non-uniformity correction scheme is proposed and analyzed using the data from real camera electronics unit based on a TDI (Time Delayed Integration) type of CCD. The test results show that the performance of the conventional non-uniformity correction scheme is affected significantly when the video gain is added. On the other hand, in our proposed scheme, the performance is not dependent on the video gain. The insensitivity of the non-uniformity performance on the video-gain is mainly due to the fact that the correction is performed after the dark signal is subtracted from system response.

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

A Study about Vortex Flow Characteristics on Delta wing by Wime-Resolving PIV (시간해상도 PIV를 이용한 델타형 날개에서의 와류유동특성에 관한 연구)

  • Lee Hyun;Kim Beom-Seok;Sohn Myong-Hwan;Lee Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.105-108
    • /
    • 2002
  • Highly swept leading edge extension(LEX) applied to delta wings has greatly improved the subsonic maneuverability of contemporary fighters. In this study, systematic approach by PIV experimental method within a circulating water channel was adopted to study the fundamental characteristics of induced vortex generation, development and its breakdown appearing on a delta wing model with or without LEX in terms of four angles of attack$(15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ})$ and six measuring sections$(30\%,\;40\%,\;50\%,\;60\%,\;70\%,\;80\%)$ of chord length. Distributions of time-averaged velocity vectors and vorticities over the delta wing model were compared along the chord length direction. High-speed CCD camera which made it possible to acquire serial images is able to get the detailed information about the flow characteristics occurred on the delta wing. Especially quantitative comparison of the maximum vorticity featuring the induced pressure distribution were also conducted to clarity the significance of the LEX existence.

  • PDF