• Title/Summary/Keyword: CCD

Search Result 2,857, Processing Time 0.034 seconds

Characteristics of bridge task in Korean coastal large trawler (우리나라 근해 대형트롤 어선의 선교업무 특성)

  • Kim, Min-Son;Shin, Hyeon-Ok;Lee, Ju-Hee;Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.301-310
    • /
    • 2013
  • To suggest a standard concerning with the arrangement of bridge equipment, the authors conducted the video observations with 3CCD (charge coupled device) cameras installed on the ceil of the bridge for monitoring the working activities of two bridge teams (the skipper/mate1 and the skipper/mate2) in a Korean coastal large trawler(gross tonnage: 139) for five days from July 30th. 2010 and analyzed of the data. Work elements coded by the work activities were input on the sheet of work analysis by the time unit of 1 sec according to the time occurred. A single work element among the work activities for every 5 minutes was denoted as the number of occurrence. The frequency of equipment usage was limited only in the usage of the equipment. In the case of the navigation and the towing net two ranks were integrated and analyzed. On the other hand, in the case of the casting net and the hauling net, two processes were integrated to as one and then analyzed separately as two ranks. As the results, 15 elements of work was carried out between two bridge teams for the observation; lookout, radar, GPS plotter, fish finder, net monitor, fishing deck, RPM indicator, rudder angle indicator, compass card, for maneuver; steering, ship speed control, trawl winch operation and external communications, paper works and others. It was found that the work load of the skipper per 5 minutes accordance with the navigation, the casting net, the towing net and the hauling net are 20.5 times, 11.9 times, 38.0 times and 9.5 times respectively, the mates are 65.2 times, 66.5 times, 85.7 times and 59.1 times respectively. The radar was shown the highest frequency of the equipment usage and the next was the fish finder, the GPS plotter and the external communications in the case of the navigation. In the case of the towing net the frequency of usage was high the ranking as the radar, the net monitor, the fish finder, the GPS plotter, the steering system and the external communications. In the case of the integrated process both of the casting and hauling net the trawl winch was shown the highest frequency to the skipper and the next was the GPS plotter and the radar, and the steering system was shown the highest frequency to the mate and the next was the radar, the ship speed control system, the GPS plotter, the net monitor and the fish finder.

Mechanism of $Ca^{2+}$ Regulation in Osteoblast-like Cells (골아세포내 $Ca^{2+}$ 활성도의 조절기전)

  • Park, Mi-Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.1 no.1
    • /
    • pp.25-41
    • /
    • 1999
  • Physiological activity of osteoblast including bone formation is known to be closely related to the increase of intracellular $Ca^{2+}$ activity($[Ca^{2+}]_i$) in osteoblast. $Ca^{2+}$ is an important intracellular messenger in diverse cellular functions, and regulation of its level is mediated by the transmembrane $Ca^{2+}$ movement via $Ca^{2+}$ channels, $Na^+-Ca^{2+}$ exchange, and by intracellular $Ca^{2+}$ movement through the intracellular stores. The purpose of this study is to investigate how the intracellular $Ca^{2+}$ is regulated in osteoblast-like cells(OLCs) by measuring $Ca^{2+}$ activity with cell imaging technique. OLCs were isolated from femur and tibia of neonatal rats, and cultured for 7 days. Cultured OLCs were loaded with a $Ca^{2+}$-sensitive fluorescent dye, Fura-2, and fluorescence images were monitored with a cooled CCD camera. The images were processed and analyzed with an image analyzing software. The results were as follows. (1) $[Ca^{2+}]_i$ of OLC decreased as the $Ca^{2+}$ concentration in the superfusing Tyrode solution was lowered. When $Na^+$ concentration in the superfusing solution was decreased, $[Ca^{2+}]_i$ increased.. These suggest that $Ca^{2+}$ flux occurs via the $Na^+-Ca^{2+}$ exchange mechanism. (2) When $Na^+$ in the superfusing solution was removed. a transient $Ca^{2+}$, increase($Ca^{2+}$ spike) was occasionally observed. However, $Ca^{2+}$ spike was not observed after adding 1 ${\mu}M$ thapsigargin. This implies that the generation of $Ca^{2+}$ spike is mediated by the release of $Ca^{2+}$ from endoplasmic reticulum(ER). (3) As the $Ca^{2+}$ concentration in the superfusing solution was raised, the frequency of 0mM $Na^+$-induced $Ca^{2+}$ spike increased, suggesting that $Ca^{2+}$-induced $Ca^{2+}$ release(CICR) mechanism exists. (4) After $[Ca^{2+}]_i$ was decreased with the superfusion of $Ca^{2+}$-free solution containing thapsigargin, the recovery of $[Ca^{2+}]_i$ with reperfusion of 2.5mM $Ca^{2+}$ solution transiently exceeded the control level, suggesting that the depletion of $Ca^{2+}$ in ER induces $Ca^{2+}$ influx from extracellular medium via store-operated $Ca^{2+}$ influx(SOCI) mechanism. (5) $[Ca^{2+}]_i$ was not affected by the superfusion of 25mM $K^+$ Tyrode solution. These results suggest that intracellular $Ca^{2+}$ activity in osteoblast is regulated by transmembrane $Ca^{2+}$ flux via $Na^+-Ca^{2+}$ exchange, $Ca^{2+}$ release from the internal store (ER) via $Ca^{2+}$-induced $Ca^{2+}$ release, and store-operated $Ca^{2+}$ influx across the cell membrane.

  • PDF

Intensity Compensation for Efficient Stereo Image Compression (효율적인 스테레오 영상 압축을 위한 밝기차 보상)

  • Jeon Youngtak;Jeon Byeungwoo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.101-112
    • /
    • 2005
  • As we perceive the world as 3-dimensional through our two eyes, we can extract 3-dimensional information from stereo images obtained from two or more cameras. Since stereo images have a large amount of data, with recent advances in digital video coding technology, efficient compression algorithms have been developed for stereo images. In order to compress stereo images and to obtain 3-D information such as depth, we find disparity vectors by using disparity estimation algorithm generally utilizing pixel differences between stereo pairs. However, it is not unusual to have stereo images having different intensity values for several reasons, such as incorrect control of the iris of each camera, disagreement of the foci of two cameras, orientation, position, and different characteristics of CCD (charge-coupled device) cameras, and so on. The intensity differences of stereo pairs often cause undesirable problems such as incorrect disparity vectors and consequent low coding efficiency. By compensating intensity differences between left and right images, we can obtain higher coding efficiency and hopefully reduce the perceptual burden of brain to combine different information incoming from two eyes. We propose several methods of intensity compensation such as local intensity compensation, global intensity compensation, and hierarchical intensity compensation as very simple and efficient preprocessing tool. Experimental results show that the proposed algerian provides significant improvement in coding efficiency.

Development of a Low-cost Monocular PSD Motion Capture System with Two Active Markers at Fixed Distance (일정간격의 두 능동마커를 이용한 저가형 단안 PSD 모션캡쳐 시스템 개발)

  • Seo, Pyeong-Won;Kim, Yu-Geon;Han, Chang-Ho;Ryu, Young-Kee;Oh, Choon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.61-71
    • /
    • 2009
  • In this paper, we propose a low-cost and compact motion capture system which enables to play motion games in PS2(Play Station 2). Recently, motion capture systems which are being used as a part in film producing and making games are too expensive and enormous systems. Now days, motion games using common USB camera are slow and have two-dimension recognition. But PSD sensor has a few good points, such as fast and low-cost. In recently year, 3D motion capture systems using 2D PSD (Position Sensitive Detector) optic sensor for motion capturing have been developed. One is Multi-PSD motion capture system applying stereo vision and another is Single-PSD motion capture system applying optical theory ship. But there are some problems to apply them to motion games. The Multi-PSD is high-cost and complicated because of using two more PSD Camera. It is so difficult to make markers having omni-direction equal intensity in Single-PSD. In this research, we propose a new theory that solves aforementioned problems. It can measure 3D coordination if separated two marker's intensity is equal to. We made a system based on this theory and experimented for performance capability. As a result, we were able to develop a motion capture system which is a single, low-cost, fast, compact, wide-angle and an adaptable motion games. The developed system is expected to be useful in animation, movies and games.

An Efficient Dead Pixel Detection Algorithm Implementation for CMOS Image Sensor (CMOS 이미지 센서에서의 효율적인 불량화소 검출을 위한 알고리듬 및 하드웨어 설계)

  • An, Jee-Hoon;Shin, Seung-Gi;Lee, Won-Jae;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.55-62
    • /
    • 2007
  • This paper proposes a defective pixel detection algorithm and its hardware structure for CCD/CMOS image sensor. In previous algorithms, the characteristics of image have not been considered. Also, some algorithms need quite a time to detect defective pixels. In order to make up for those disadvantages, the proposed defective pixel detection method detects defective pixels efficiently by considering the edges in the image and verifies them using several frames while checking scene-changes. Whenever scene-change is occurred, potentially defective pixels are checked and confirmed whether it is defective or not. Test results showed that the correct detection rate in a frame was increased 6% and the defective pixel verification time was decreased 60%. The proposed algorithm was implemented with verilog HDL. The edge indicator in color interpolation block was reused. Total logic gate count was 5.4k using 0.25um CMOS standard cell library.

DEVELOPMENT OF FILTERING SYSTEM OF LASER FLUORESCENCE FOR IMPROVEMENT OF THE DIAGNOSTIC SENSITIVITY FOR DENTAL CARIES (레이저 형광법의 치아우식증 진단감도를 증진시키기 위한 필터링 시스템 개발)

  • Lee, Sang-Ho;Park, Jong-Whi;Kook, Jung-Ki;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • The objective of this study is to improve the optical sensitivity of laser fluorescence for detection of incipient enamel caries. An incipient carious lesion was formed in various stages by placing an enamel specimen of a bovine tooth in STPP demineralization solution. After measuring the optical density of the lesion surface by laser fluorescence induced by argon laser and various alter of yellow(500-520nm), amber(520-540nm), orange(540-560nm), and red(560-580nm), the specimen was cut vertically to measure the depth of the lesion using a polarizing microscope. SAS statistical program was used to analyze the relationship between the optical density of the lesion suface and the depth of the lesion. The results were as follows: 1. The optical density of early carious lesion, measured by laser fluorescence with amber and orange filter, and lesion depth observed by polarizing microscope, were increased as demineralization time increased. 2. The correlation coefficient between optical density of the lesion surface and the histological depth of the lesion was the highest in orange filter(r=0.49), followed by amber(r=0.32), yellow(r=0.13) and red(0.01). 3. Regression analysis showed that the most linear relationship between the optical density and the lesion depth was existed in orange filter group. In regard above results, laser fluorescence could be considered to be reliable for optical diagnosis of dental caries.

  • PDF

An Adaptive Colorimetry Analysis Method of Image using a CIS Transfer Characteristic and SGL Functions (CIS의 전달특성과 SGL 함수를 이용한 적응적인 영상의 Colorimetry 분석 기법)

  • Lee, Sung-Hak;Lee, Jong-Hyub;Sohng, Kyu-Ik
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.5
    • /
    • pp.641-650
    • /
    • 2010
  • Color image sensors (CIS) output color images through image sensors and image signal processing. Image sensors that convert light to electrical signal are divided into CMOS image sensor and CCD image sensor according to transferring method of signal charge. In general, a CIS has RGB output signals from tri-stimulus XYZ of the scene through image signal processing. This paper presents an adaptive colorimetric analysis method to obtain chromaticity and luminance using CIS under various environments. An image sensor for the use of colorimeter is characterized based on the CIE standard colorimetric observer. We use the method of least squares to derive a colorimetric characterization matrix between camera RGB output signals and CIE XYZ tristimulus values. We first survey the camera characterization in the standard environment then derive a SGL(shutter-gain-level) function which is relationship between luminance and auto exposure (AE) characteristic of CIS, and read the status of an AWB(auto white balance) function. Then we can apply CIS to measure luminance and chromaticity from camera outputs and AE resister values without any preprocessing. Camera RGB outputs, register values, and camera photoelectric characteristic are used to analyze the colorimetric results for real scenes such as chromaticity and luminance. Experimental results show that the proposed method is valid in the measuring performance. The proposed method can apply to various fields like surveillant systems of the display or security systems.

Enhancement of Anti-inflammation Effect by Fermentation Process in Aronia melanocarpa (Michx.) Elliott Extract (발효 공정을 통한 아로니아 추출물의 항염증 효능 증진)

  • Kim, Nam Young;Lee, Young Duck;Cho, Seok Cheol;Shin, Yun Chul;Lee, Hyeon Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.6
    • /
    • pp.475-482
    • /
    • 2014
  • This study was indicated to enhance the anti-inflammation activities by the fermentation of the fruits of Aronia melanocarpa (Michx.) Elliott. The extracts by 70% ethanol (EE) showed better biological activities than those by hot water (WE) from campared result of the effect of extraction solvents. Then, the extract from 70% ethanol extraction was further fermented by lactic acid, denoted as FEE. For antioxidant activities, the FEE had showed the highest value as 0.832 of reducing powder, in comparison with those of EE and WE. Cytotoxicity of the water extraction (WE) was measured for 12.06% in addition of $1.0mg/m{\ell}$ of FEE. For anti-inflammation activities, NO production from the macrophage, RAW 264.7 was observed as $7.24{\mu}M$ and $8.52{\mu}M$ from FEE and EE, respectively. Prostaglandin $E_2$ ($PGE_2$) production from human fibroblast cell, CCD-986sk, was also estimated for $152pg/m{\ell}$ in addition of $1.0mg/m{\ell}$ of the FEE. The lowest production of both IL-6 and TNF-${\alpha}$ were $3.5pg/m{\ell}$ and $865.5pg/m{\ell}$, respectively in addition of $1.0mg/m{\ell}$ of the FEE, whereas $74.5pg/m{\ell}$ and $982.4pg/m{\ell}$ in treated with same concenrations of the EE. It was also found that the FEE was higher amounts than other extracts through HPLC analysis of the anthocyanins. These results strongly indicate that fermentation process of the lactic acid could enhance anti-inflammation activities of extracts by increasing the amounts of the anthocyanins, especially cyanidin-galactoside. Our results suggest that the application of the fermentation process for other medicinal herbs can be improved their biological activities.

A Study on the Performance Improvement of Bar Code Reader for the Automatic Processing of the Mail Items (우편물 자동처리를 위한 바코드 판독기 성능개선에 관한 연구)

  • Park, Moon-Sung;Nam, Yun-Seok;Kim, Hey-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.731-734
    • /
    • 2001
  • 우편물을 집배원이 배달하는 순서로 자동구분 처리하기 위한 요소기술 줌에서 4-state 바코드 시스템이 개발되고 있으며 우편번호, 배달순서코드, 고객정보 등이 적용될 예정이다. 기존의 고객 바코드 판독 시스템은 우편물상의 바코드 심볼로지가 존재하는 판독대상 영역의 기울기가 ${\pm}4.47^{\circ}$ 이하이고, 심볼의 훼손과 잡영이 없을 경우에 $79{\sim}100msec(35,000{\sim}45,000$통/시간)의 속도로 자동 구분 정보가 판독된다. 본 논문에서는 판독범위 및 판독성능을 개선을 위하여 CCD(Charge Coupled Device) 센서로부터 획득된 이미지상에서 존재하는 심볼로지 정보의 고속판독 방법을 제시한 것이다. 이 판독방법은 그레이(gray) 이미지 바탕면의 경계값(threshold) 기울기 분포를 기준으로 2개의 경계값을 설정하여 판독대상 정보를 획득하였다. 또한, 4-state 바코드 심볼로지의 존재 가능성 영역만을 탐색하고, 판독대상 영역에서 트래커(tracker)를 탐색하여 심볼로지의 기울기값, 심볼로지 경계값, 심볼위치 좌표값을 생성한 후 심볼값이 판독한 것이다. 판독시험 결과는 판독대상 영역의 심볼로지가 ${\pm}45^{\circ}$ 기울어지고, 잡영이 존재할 경우에도 $30{\sim}60msec(58,000{\sim}l16,000$통/시간) 이내에 판독되었다. 우편물 자동구분용 바코드 판독기로써 적용될 경우에 판독속도가 평균 57.25% 이상 개선되고, 판독범위의 확장으로 0.2%의 기계적인 오류(이송과정예서의 Jam 발생 비율)를 제외할 경우에 거의 99.8% 우편물을 판독하여 자동구분 처리할 수 있게 될 것으로 기대된다.onebook 엑세스 모들(Server Phonebook Access Module)로 구성되어 있다.외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만

  • PDF

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF