• Title/Summary/Keyword: CC V2.3

Search Result 107, Processing Time 0.024 seconds

Application of a New Conjugation Method to Fish Pathogenic Bacteria Containing R Plasmid for the Analysis of Drug-Resistant Status in Aquaculture (새로운 conjugation 방법을 응용한 R plasmid 함유 어병세균의 분리와 양식장 내성균의 현황 분석)

  • Yoo Min Ho;Jeong Joon Beom;Kim Eun Heui;Lee Hyoung Ho;Jeong Hun Do
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 2002
  • To develop a new method of conjugation and to determine the distribution of R plasimds, we isolated multi-drug resistant strains from fish pathogenic bacteria in the farms of south and east seacoasts of Korea. Out of the 134 isolates examined, 10 showed resistance to chloramphenicol, tetracycline, streptomycin, ampicillin, colistin, nalidixic acid, oxolinic acid and kanamycin. One out of 10 multi-drug resistance bacteria, Vibfio damsela JE1 (V. damsela JE1), contained transferable R plasmid of chlorarnphenicol- tetracycline resistance genes and other nucleic acids encoding ampicillin and kanamycin resistance. The presence of the R plasmid was confirmed by conjugation using the chromocult medium (CC) as a selective and differential medium for transconiugants with identification based on the growth or colors of the colonies. The frequency of R plasmid transfer with filter mating method was come out much higher than that of broth mating method and appeared to be dependent upon the mating time and temperature. The optimum conditions for filter mating method were found to be 30$^{\circ}C$ and 24hrs as mating temperature and period, respectively, Moreover, donor cells with R plasmid, both isolate and standard bacteria, were shown to have an ability to transfer the plasmid against Escherichia coli K-12 HB101 (E. coli HB101) and Edwardsiella tarda (E. tarda) RE14 at fairly high frequencies, finally, we isolated 3 isolates of Sphingomonas sp., carrying R plasmid from 12 multi-drug resistant bacteria in normal microflora of the flounder (Paralichthys olivaceus) group used for the isolation of V emsela JE1 four months before. The same size and gene transfer chayateristics of R plasimds with those of V damsela JE1 confirmed that normal microflora have the reservoir activity for R plasmid in natural aquatic environment.

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

Preliminary Result in Patients with Primary Hepatoma Treated by Stereotactic Radiotherapy (원발성 간암에 대한 정위방사선치료의 예비결과)

  • Kang Ki Mun;Choi Ihl Bohng;Kim In Ah;Choi Byung Ock;Kang Young Nam;Chai Gyu Young;Han Sung Tae;Chung Gyu Won
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2001
  • Purpose : It is not common to evaluate the response of the fractionated stereotactic radiotherapy (SRT) to primary hepatoma as compared with conventional radiotherapy. The purpose of the study was to take the preliminary result on the clinical trial of primary hepatoma by SRT. Materials and Methods : From July 1999 to March 2000, thirty three patients were hospitalized in the St. Mary's Hospital, and treated with SRT for extracranial tumors. Among them, 13 patients were diagnosed to primary hepatoma and then applied by frameless SRT using 6 MV linac accelerator. There were 12 male and 1 female patients. They had the age of $ 44\~66$ year old (median : 59) and the tumor size of $10\~825\;cc$ (median : 185 cc). SRT was given to them $3\~5$ fractions a week (5 Gy/fraction, $90\%$ isodose line) for $2\~3$ weeks. Median dose of SRT was 50 Gy and the range was $30\~50\;Gy$. Results : Follow-up period ranged from 3 months to 13 months with median of 8 months. After treating SRT to thirteen patients with primary hepatoma, the response of the tumor was examined by abdominal CT : they are classified by 1 complete regression $(7.7\%)$, 7 partial regression $(53.8\%)$, 4 minimal regression $(30.8\%)$, 1 stable disease $(7.7\%)$. The positive responses more than partial remission were 8 patients $(61.5\%)$ after the treatment. The level of serum alpha-fetoprotein (AFP) after the treatment as compared with pretreatment had been $92.3\%$ decreased. There was no severe complication except dyspepsia $84.6\%$, mild nausea $69.2\%$, transient decreased of hepatic function $15.4\%$ and fever $7.7\%$. Conclusion : SRT to the patients with primary hepatoma was potentially suggested to become the safe and more effective tool than the conventional radiotherapy even though there were relatively short duration of follow-up and small numbers to be tested.

  • PDF

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

A Study on the Natural Sex Ratio and Fertility of Galvanized Boar Semen (돼지의 자연성비와 정자의 전기분이에 의한 수태성적에 관한 연구)

  • 이용빈;오봉국;권종국;서국성;정영철;오성종
    • Korean Journal of Animal Reproduction
    • /
    • v.3 no.1
    • /
    • pp.56-60
    • /
    • 1979
  • This study was carried out to find the difference between the naturaly born sex rtio among 1,242 head of pigs(120 litters) at Swine Farm, Cheil Sugar Co. and B-body a, pp.arance from their semen, and to find the conception rates which were inseminated to 40 sows with sperm from the anode and cathode after electrophoresis of boar semen. In order to the electrophoretic separation, the semen was placed into the platimum loop electrodes(105 cc) at room temperature for 30 minutes with D.C. 3V. and 350${\mu}$A. constant. The sperm fluorescent staining method was performed in accordance with Bhattacharya's(1970) method. The spermatozoa were observed through a Olympus Vanox microscope(made in Japan) using exciter filter with I heat barrier HPO 120. The results obtained were summarized as follows: 1. The natural sex ratio of 1,242 piglets(120 litters) which were born at Swine Farm, Cheil Sugar Co. was 50%, and B-body a, pp.arance of its boar semen were 49.24%. 2. With electrophoretic separation, the anode and cathode attracted 65.5${\pm}$5.03% and 29.89${\pm}$4.29% of B-body bearing sperm, respectively. 3. After electrophoresis of boar sperm, they were inseminated to 40 sows with sperm from anode and cathode. The conception rate was 92.5%.

  • PDF

Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

  • Mattes, Malcolm D.;Zhou, Ying;Berry, Sean L.;Barker, Christopher A.
    • Radiation Oncology Journal
    • /
    • v.34 no.2
    • /
    • pp.145-155
    • /
    • 2016
  • Purpose: Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Materials and Methods: Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. Results: In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung $V_{20}$ (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum $D_{max}$ (13.6 vs. 38.9 Gy), bowel $D_{200cc}$ (7.3 vs. 23.1 Gy), femur $D_{50}$ (34.6 vs. 57.2 Gy), and genitalia $D_{max}$ (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus $D_{mean}$ (16.9 vs. 22.4 Gy), brachial plexus $D_5$ (57.4 vs. 61.3 Gy), bladder $D_5$ (26.8 vs. 36.5 Gy), and femur $D_{50}$ (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Conclusion: Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients.

A Study on the Directional Dependence of Scatter Ray in Radiography (X선 촬영시 산란선 방향 의존성에 관한 연구)

  • Oh, Hyun-Joo;Kim, Sung-Soo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.18 no.1
    • /
    • pp.63-70
    • /
    • 1995
  • In this pauper, the back, forward, side and $45^{\circ}$ oblique scatter dose were measured the X-ray exposure conditions 60, 80, 100, 120kV, FFD 100cm, FS $20\times20cm$, toward the $25\times25cm\times10\sim20cm$ of solid water, paraffin and MiX-DP phantom, and Pb, Cu, Al, and styrofoam meterials, by the electrometer and 5.3 cc ionization chamber. The obtained results are summarized as following. 1. The percentage depth dose(PDD) at the range of the diagnostic x-ray energy were appeared 50 % depth dose at the 2 cm depth with 60 kV, and 5 cm depth with 120 kV X-ray, 10 % depth dose at the 10 cm depth with 60 kV and 14 cm depth with 120 kV X-ray, 5 % below depth dose at the 20 cm depth. 2. The back scatter dose which were generated the surface of Pb, Cu and Al metal plates were 10 % below, and than the back scatter dose at the Pb plate were a most amount of these which were about 10 %, and were appeared the order of Cu and Al. 3. The percentage forward scatter were appeared from 50 % to 65 %, and the more phantom thicknees become, the more forward scatter were increased with the ratio of 5 % per 5 cm thickness. 4. The percentage back scatter which were generated the tissue equivalence meterials solid water, paraffin and MiX-DP were from 20 % to 40 %, and than the back scatter dose at the solid water were a mest amount of those, and paraffin and MiX-DP were appeared with the next values. 5. The percentage $90^{\circ}$ lateral and $45^{\circ}$ oblique side scatter dose were measured from 4 % to 12 %. a most amount of scatter dose which were generated from the patient in radiography were the forward scatter, the next values were the back scatter, the third values were the $90^{\circ}$ lateral scatter.

  • PDF

Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture (견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술)

  • Kim Jin Sub;Jun Jin Ho;Chung Yung Khee
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

Space Weather Effects on GEO Satellite Anomalies during 1997-2009

  • Choi, Ho-Sung;Lee, Jae-Jin;Cho, Kyung-Suk;Cho, Il-Hyun;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.30.2-30.2
    • /
    • 2010
  • Numerous operational anomalies and satellite failures have been reported since the beginnings of the "space age". Space weather effects on modern spacecraft systems have been emphasized more and more as increasing their complexity and capability. Energetic particles potentially can destroy and degrade electronic components in satellites. We analyzed the geostationary (GEO) satellite anomalies during 1997-2009 to search possible influences of space weather on the satellite anomalies like power problem, control processor problem, attitude control problem, etc. For this we use particle data from GOES and LANL satellites to investigate space weather effects on the GEO satellites' anomalies depending on Kp index, local time, seasonal variation, and high-energy electron contribution. As results, we obtained following results: (1) there is a good correlation between geomagnetic index(Kp) and anomaly occurrences of the GEO satellite; (2) especially during the solar minimum, occurrence of the satellite anomalies are related to electron flux increase due to high speed solar wind; (3) satellite anomalies occurred more preferentially in the midnight and dawn sector than noon and dusk sector; (4) and the anomalies occurred twice more in Spring and Fall than Summer and Winter; (5) the electron with the lowest energy channel (50-75keV) has the highest correlation (cc=0.758) with the anomalies. High association between the anomalies and the low energy electrons could be understand by the facts that electron fluxes in the spring and fall are stronger than those in the summer and winter, and low-energy electron flux is more concentrated in the dawn sector where the GEO satellite anomalies occurred more frequently than high-energy electron flux. While we could not identify what cause such local time dependences, our results shows that low-energy electrons (~100keV) could be main source of the satellite anomaly, which should be carefully taken into account of operating satellites.

  • PDF

A Study of Properties and Coating Natural Mineral Pumice Powder of in Korea (한국산 천연 광물 부석 파우더 코팅 및 특성에 관한 연구)

  • Kim, In-Young;Noh, Ji-Min;Nam, Eun-Hee;Shin, Moon-Sam
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.498-506
    • /
    • 2019
  • This study is based on a coating method that provides utilization value as a micronised powder for cosmetic raw materials using natural minerals buried in Bonghwa, Gyeongsangbuk-do in Korea. The mineral powder name is called Buseok, and chemical name is pumice powder. The results of a study on the efficacy of cosmetics are reported by the development of particulate powder to assess the performance of this powder. First of all, in order to coat the surface of this powder with oil, aluminum hydroxide was coated on the particulate surface and then coated with alkylsilan. In addition, it was coated with vegetable oil to prevent condensation of the powder and increase the dispersion in the oil phase. First; the particle size of pumice powder was from 10 to 50mm having porous holes on the surface of the particles. Second; The components of this powder contained $SiO_2$, $Al_2O_3$, $Fe_2O_3$, MgO, CaO, $K_2O_2$, $Na_2O$, $TiO_2$, $TiO_2$, MnO, $Cr_2O_3$, $V_2O_5$. Third: The particles of this powder have a planetary structure and are reddish-brown with porosity through SEM and TEM analysis. Fourth; the far-infrared radiation rate of this parabolic powder was $0.924{\mu}m$, and the radiative energy was $3.72{\times}102W/m^2$ and ${\mu}m$. In addition, the anion emission is 128 ION/cc, which shows that the coating remains unchanged. Based on these results, it is expected to be widely applied to basic cosmetics such as BB cream, cushion foundation, powderfect, and other color-coordinated cosmetics, sunblock cream, wash-off massage pack as an application of cosmetics. (Small and Medium Business Administration: S2601385)