• Title/Summary/Keyword: CC/hMG

Search Result 58, Processing Time 0.026 seconds

Artificial Culture Method of Coriolus versicolor (Fr.) Quel. Mushrooms (구름버섯(Coriolus versicolor (Fr.) Quel.)의 인공재배법 개발)

  • Jo, Woo-Sik;Yun, Yeong-Seok;Rew, Young-Hyun;Park, Sun-Do;Choi, Boo-Sull;Uhm, Jae-Youl
    • The Korean Journal of Mycology
    • /
    • v.26 no.1 s.84
    • /
    • pp.25-30
    • /
    • 1998
  • Present expriments were conducted to determine the possibility of cultivation of Coriolus versicolor selected among the higher fungi growing in Korea. Dried apple sawdust used in this study consisted of 31.5% C, 0.54% N, 2.41 % CaO, 0.05% $P_2O_5$, 0.48% MgO and 0.81% $K_2O$(pH 5.6). Coriolus versicolor mushrooms were cultivated on the sawdust media; apple sawdust; rice bran=80:20 in 850cc polypropylene bottles. The isolate of Coriolus versicolor used was YCV collected from an Apple farm in Youngchun district. It took 34 days to make fruitbody from spawning. The fruit bodies produced the total fresh weight 28 g in a bottles, and converted to 64% of fresh weight.

  • PDF

Comparison of Vegetation Structure and Environmental Factors between the Disturbed and Undisturbed Wetlands around the Littoral Zone of Namgang (남강의 연안대 습지에서 교란지와 비교란지의 식생구조와 환경요인의 비교)

  • Gang, Seon-Hee;Lee, Pal-Hong;Son, Sung-Gon;Kim, Cheol-Soo;Oh, Kyung-hwan
    • Journal of Wetlands Research
    • /
    • v.3 no.1
    • /
    • pp.1-17
    • /
    • 2001
  • The flora, vegetation structure, distribution of the vascular plants, physico-chemical characteristics of sediment, and nutrient contents of palnts were investigated in the ten disturbed and undisturbed wetlands around the littoral zone of Namgang, Jinju-si, Gyongsangnam-do, Korea from August 7 to August 15 in 1999. 217 taxa of the vascular plants distributed into 2 formas, 26 varieties, 189 species belong to 142 genera under 52 families were sampled or recorded. Dominant species of the undisturbed and the disturbed area were Persicaria thunbergii and Ambrosia artemisiifolia var. elatior, of which importance values were 13.86, and 15.81, respectively. Among 26 species of the naturalized plants, importance value of Ambrosia artemisiifolia var. elatior was highest as 9.54. The ranges of species diversity indices (H') were 1.370~1.819, and highest in the site 1 of the undisturbed area. The ranges of eqitability (J') were 0.779~0.902, and highest in the site 8 of the disturbed area. The ranges of community similarity indices ($CC_s$) were 0.341~0.578 among the ten wetlands, and highest between site 1 and site 2 which were the undisturbed area. The ranges of sediment properties such as pH, conductivity, organic matter, total phosphorus, and total nitrogen were 5.17~7.35, $24.67{\sim}74.33{\mu}mhocm^{-1}$, 1.09~3.82%, 0.0008~0.0034 mg/100g, and 0.06~0.15%, respectively. Nutrient contents of plants such as total nitrogen and total phosphorus were 1.52~2.65% and $0.010{\sim}0.039mg100g^{-1}$, respectively. It was recommended that the establishment of the conservation area was necessary to ensure the habitat for wild life and to maintain the diversity of the vascular hydrophytes and hygrophytes.

  • PDF

In-Hospital Outcomes of Acute Renal Failure Requiring Continuous Renal Replacement Therapy in Patients with On-pump CABG (심폐기 가동하 관상동맥우회술 후 발생한 급성신부전 환자들에 있어 지속적 신대체요법의 병원 내 결과)

  • Kim, Young-Du;Park, Kuhn;Kang, Chul-Ung;Yoon, Jeong-Seob;Moon, Seok-Whan;Wang, Young-Pil;Jo, Kuhn-Hyun
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.32-36
    • /
    • 2007
  • Background: Although acute renal failure (ARF) after coronary artery bypass graft (CABG) is relatively rare, but devastating complication with high mortality. Our study aims to evaluate the effectiveness of early application of CRRT in patients with ARF which developed after on-pump CABG. Material and Method: Two hundred and eighty seven patients underwent isolated on-pump CABG between May 2002 and Feb. 2006 at our institution, of whom 15 (5.2%) needed CRRT (11 patients for postoperatively developed ARF and the remaining 4 patients with preexisting dialysis-dependent chronic renal failure (CRF) for postoperative hemodynamic and metabolic control). Criteria for early application of CRRT were as follows; decreased urine output less than 0.5cc/h/kg for 2 consecutive hours and elevated serum creatinine level greater than 2.0 mg/dL. Result: The incidence of ARF requiring CRRT after on-pump CABG was 3.9% (11/283) and the overall hospital mortality of patient with CRRT was 33.3% (5/15). Of 5 deaths, 4 were patients with postoperatively developed ARF, and 1 was a patient with pre-existing dialysis-dependent CRF patient. The mean time between the operation and the initiation of CRRT was $25.8{\pm}5.8$ hours and the mean duration of CRRT was $62.1{\pm}41.2$ hours. Of the 7 survivors who were not on dialysis-dependent preoperatively, 6 patients fully recovered renal function during hospital stay and 1 patient required permanent renal supportive treatment after discharge from hospital. Conclusion: Early application of CRRT could maintain stable postoperative hemodynamic status and make outcomes better than those of previous reports in patients with ARF which developed after on-pump CABG.

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF

AC transport current loss analysis for a face-to-face stack of superconducting tapes

  • Yoo, Jaeun;Youm, Dojun;Oh, SangSoo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.34-38
    • /
    • 2013
  • AC Losses for face to face stacks of four identical coated conductors (CCs) were numerically calculated using the H-formulation combined with the E-J power law and the Kim model. The motive sample was the face to face stack of four 2 mm-wide CC tapes with 2 ${\mu}m$ thick superconducting layer of which the critical current density, $J_c$, was $2.16{\times}10^6A/cm^2$ on IBAD-MgO template, which was suggested for the mitigation of ac loss as a round shaped wire by Korea Electrotechnology Research Institute. For the calculation the cross section of the stack was simply modeled as vertically aligned 4 rectangles of superconducting (SC) layers with $E=E_o(J(x,y,t)/J_c(B))^n$ in x-y plane where $E_o$ was $10^{-6}$ V/cm, $J_c$(B) was the field dependence of current density and n was 21. The field dependence of the critical current of the sample measured in four-probe method was employed for $J_c$(B) in the equation. The model was implemented in the finite element method program by commercial software. The ac loss properties for the stacks were compared with those of single 4 cm-wide SC layers with the same critical current density or the same critical current. The constraint for the simulation was imposed in two different ways that the total current of the stack obtained by integrating J(x,y,t) over the cross sections was the same as that of the applied transport current: one is that one fourth of the external current was enforced to flow through each SC. In this case, the ac loss values for the stacks were lower than those of single wide SC layer. This mitigation of the loss is attributed to the reduction of the normal component of the magnetic field near the SC layers due to the strong expulsion of the magnetic field by the enforced transport current. On the contrary, for the other case of no such enforcement, the ac loss values were greater than those of single 4cm-wide SC layer and. In this case, the phase difference of the current flowing through the inner and the outer SC layers of the stack was observed as the transport current was increased, which was a cause of the abrupt increase of ac loss for higher transport current.

Assisted Reproductive Technology in Infertile Patients with Endometriosis (자궁내막증과 동반된 불임환자의 보조생식술을 이용한 치료)

  • Moon, Shin-Yong;Lee, Kyung-Soon;Roh, Jae-Sook;Suh, Chang-Suk;Kim, Seok-Hyun;Choi, Young-Min;Shin, Chang-Jae;Kim, Jung-Gu;Lee, Jin-Young;Chang, Yoon-Seok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.22 no.2
    • /
    • pp.211-220
    • /
    • 1995
  • Though the endometriosis is not always related with infertility, endometriosis causes infertility in some patients. There are many treatment modalities of infertile patients who have endometriosis. In recent years, Assisted Reproductive Technology(ART) have been widely accepted as being a useful tool for the treatment of infertile endometriotic patients. The objective of this study was to evaluate the outcome of ART in infertile endometriotic patients who have been carried out IVF-ET from Jan, 1992 to Dec, 1994 and to compare the results between COH/IUI and IVF-ET in the patients with endometriosis stage I. Tubal disease only patients were grouped(308 patient, 956 cycles) as a control. Endometriosis group was subdivided into 4 groups according to American Fertility Society classification; endometriosis stage I (45 patients, 61 cycles), stage II (26 patients, 39 cycles), stage III (26 pateitns, 37 cycles), stage IV (33 patients, 50 cycles). The outcomes of IVF-ET in endometriosis patients were as follows; The oocyte recovery rates were significantly lower in stage III, IV endometriosis. In case of stage III endometriosis, the fertilization rate was significantly lower than other stages of endometriosis. Clinical pregnancy rates per cycle were not different between the tubal group(22%) and the endometriosis group(25%). According to endometriosis stage, the implantation rate and clinical pregnancy rate were significantly lower in stage IV (5.6%, 16%) compared with other stages (I; 10.0%, 26%, II;9.8%, 31%, III;12.6%, 32%). It suggests that some factor like autoantibodies may inhibit implantation of embryos in stage IV endometriosis. To evaluate the possibility that simply increasing the number of gametes at the site of fertilization might account for pregnancies attributed to IVF-ET, the authors retrospectively analyzed the outcome of couples undergoing IUI during hMG cycles and CC cycles between 1992 and 1994 in the women with endometriosis stage 1. In case of stage I endometriosis, though the COH/IUI group showed lower FSH level and lesser age profile than IVF-ET group, IUI group has resulted in lower pregnancy rates(19.2%) compared with the IVF-ET group(26.2%). In conclusion, endometriotic infertile patients can get comparable pregnancy rates with the tubal factor infertility patients during IVF-ET program. Moreover even in stage I endometriosis, IVF-ET may be an more effective treatment modality than COH/IUI.

  • PDF

Composition and Cell Cytotoxicity of Essential Oil from Caryopteris incana Miq. in Korea (층꽃나무(Caryopteris incana Miq) 정유의 성분 분석과 세포 독성 평가)

  • Kim, Song-Mun
    • Applied Biological Chemistry
    • /
    • v.51 no.3
    • /
    • pp.238-244
    • /
    • 2008
  • The essential oil was obtained from the aerial part of Caryopteris incana Miq. by steam distillation, samples were collected by headspace (HS) and solid-phase microextraction (SPME) methods, and the compositions of the essential oil were analyzed by gas chromatography-mass spectrometry (GCMS). The fragrance of the essential oil was fougere and woody. There were sixty-nine constituents in the essential oil: 28 carbohydrates, 22 alcohols, 7 acetates, 7 ketones, 3 aldehydes, and 2 others. Major constituents were 4,6,6-trimethyl [1S-($1{\alpha},2{\beta},5{\alpha}$)]-bicyclo[3.1.1]hept-3-en-2-ol (11.8%), taucadinol (9.4%), myrtenyl acetate (9.2%), pinocarvone (7.0%), 1-hydroxy-1,7-dimethyl-4-isopropyl-2,7-cyclodecadiene (6.3%), ${\delta}$-3-carene (6.2%). By SPME extraction, forty-nine constituents were identified: 22 hydrocarbons, 16 alcohols, 6 acetates, 3 ketones, and 2 ethers. Major constituents of the SPME-extracted sample were ${\delta}$-3-carene (12.6%), (-)-myrtenyl acetate (11.2%), 6,6-dimethyl-2-methylene-bicycol [3.1.1] heptan-3-o1 (10.9%), pinocarvone (9.3%). By HS extraction, ten constituents were identified: 5 hydrocarbons, 2 amines, 1 alcohol, and 2 others. Major constituents of the HS-extracted sample were (Z)-2-fluoro-2-butene (34.9%), ${\delta}$-3-carene (6.9%), 6-(4-chlorophenul)tetrahydro-2-methyl-2H-1,2-oxazine (5.9%). The $IC_{50}$ value (0.011 ${\mu}g/mg$) in MTT assay using HaCaT keratinocyte cell line was lower than those of commercially-selling rosemary and tea tree, suggesting more toxicological studies are needed for commercial use of the essential oil of Caryopteris incana Miq.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.