• 제목/요약/키워드: CBCT(Cone-beam computed tomography)

검색결과 564건 처리시간 0.03초

Comparison of panoramic radiography and cone-beam computed tomography for assessing radiographic signs indicating root protrusion into the maxillary sinus

  • Jung, Yun-Hoa;Cho, Bong-Hae;Hwang, Jae Joon
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.309-318
    • /
    • 2020
  • Purpose: This study investigated correlations between findings on panoramic radiographs and cone-beam computed tomography (CBCT) to assess the relationship between the maxillary sinus floor and the roots of maxillary posterior teeth. In addition, radiographic signs indicating actual root protrusion into the maxillary sinus were evaluated on panoramic radiographs. Materials and Methods: Paired panoramic radiographs and CBCT images from 305 subjects were analyzed. This analysis classified 2,440 maxillary premolars and molars according to their relationship with the maxillary sinus floor on panoramic radiographs and CBCT images. In addition, interruption of the sinus floor was examined on panoramic radiographs. Results: Root protrusion into the maxillary sinus occurred most frequently in the mesiobuccal roots of the second molars. The classification according to panoramic radiographs and CBCT images was the same in more than 90% of cases when there was no contact between the root apex and the sinus floor. When the panoramic radiograph showed root protrusion into the sinus, the CBCT images showed the same classification in 67.5% of second molars, 48.8% of first molars, and 53.3% of second premolars. There was a statistically significant relationship between interruption of the sinus floor on panoramic radiographs and root protrusion into the sinus on CBCT images. Conclusion: The presence of root protrusion into the sinus on panoramic radiographs demonstrated a moderate ability to predict root protrusion into the maxillary sinus. Interruption of the maxillary sinus floor could be considered an indicator of actual root protrusion into the maxillary sinus.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

Clinical validity and precision of deep learning-based cone-beam computed tomography automatic landmarking algorithm

  • Jungeun Park;Seongwon Yoon;Hannah Kim;Youngjun Kim;Uilyong Lee;Hyungseog Yu
    • Imaging Science in Dentistry
    • /
    • 제54권3호
    • /
    • pp.240-250
    • /
    • 2024
  • Purpose: This study was performed to assess the clinical validity and accuracy of a deep learning-based automatic landmarking algorithm for cone-beam computed tomography (CBCT). Three-dimensional (3D) CBCT head measurements obtained through manual and automatic landmarking were compared. Materials and Methods: A total of 80 CBCT scans were divided into 3 groups: non-surgical (39 cases); surgical without hardware, namely surgical plates and mini-screws (9 cases); and surgical with hardware (32 cases). Each CBCT scan was analyzed to obtain 53 measurements, comprising 27 lengths, 21 angles, and 5 ratios, which were determined based on 65 landmarks identified using either a manual or a 3D automatic landmark detection method. Results: In comparing measurement values derived from manual and artificial intelligence landmarking, 6 items displayed significant differences: R U6CP-L U6CP, R L3CP-L L3CP, S-N, Or_R-R U3CP, L1L to Me-GoL, and GoR-Gn/S-N (P<0.05). Of the 3 groups, the surgical scans without hardware exhibited the lowest error, reflecting the smallest difference in measurements between human- and artificial intelligence-based landmarking. The time required to identify 65 landmarks was approximately 40-60 minutes per CBCT volume when done manually, compared to 10.9 seconds for the artificial intelligence method (PC specifications: GeForce 2080Ti, 64GB RAM, and an Intel i7 CPU at 3.6 GHz). Conclusion: Measurements obtained with a deep learning-based CBCT automatic landmarking algorithm were similar in accuracy to values derived from manually determined points. By decreasing the time required to calculate these measurements, the efficiency of diagnosis and treatment may be improved.

Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가 (Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography)

  • 홍종현;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

Endodontic management of a maxillary first molar with three roots and seven root canals with the aid of cone-beam computed tomography

  • Nayak, Gurudutt;Singh, Kamal Krishan;Shekhar, Rhitu
    • Restorative Dentistry and Endodontics
    • /
    • 제40권3호
    • /
    • pp.241-248
    • /
    • 2015
  • Variation in root canal morphology, especially in maxillary first molar presents a constant challenge for a clinician in their detection and management. This case report describes the successful root canal treatment of a three rooted right maxillary first molar presenting with three canals each in the mesiobuccal and distobuccal roots and one canal in the palatal root. The clinical detection of this morphologic aberration was made using a dental operating microscope, and the canal configuration was established after correlating and computing the clinical, radiographic and cone-beam computed tomography (CBCT) scan findings. CBCT images confirmed the configuration of the canals in the mesiobuccal and distobuccal roots to be Al-Qudah and Awawdeh type (3-2) and type (3-2-1), respectively, whereas the palatal root had a Vertucci type I canal pattern. This report reaffirms the importance of careful examination of the floor of the pulp chamber with a dental operating microscope and the use of multiangled preoperative radiographs along with advanced diagnostic aids such as CBCT in identification and successful management of aberrant canal morphologies.

Anomalies of the clivus of interest in dental practice: A systematic review

  • McCartney, Troy E.;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.351-361
    • /
    • 2021
  • Purpose: The clivus is a region in the anterior section of the occipital bone that is commonly imaged on large-volume cone-beam computed tomography (CBCT). There have been several reports of incidental clivus variations and certain pathological entities that have been attributed to the variations. This study aimed to evaluate the effects of these variations within the scope of dentistry. Materials and Methods: Medical databases (PubMed, Scopus, and Web of Science) were searched using a controlled vocabulary (clival anomalies, cone-beam CT, canalis basilaris medianus, fossa navicularis magna, clival variation). The search was limited to English language, humans, and studies published in the last 25 years. The articles were exported into RefWorks® and duplicates were removed. The remaining articles were screened and reviewed for supporting information on variations of the clivus on CBCT imaging. Results: Canalis basilaris medianus and fossa navicularis magna were the most common anomalies noted. Many of these variations were asymptomatic, with most patients unaware of the anomaly. In certain cases, associated pathologies ranged from developmental (Tornwaldt cyst), to acquired (recurrent meningitis). While no distinct pathognomonic aspects were noted, there were unique patterns of radiographic diagnosis and treatment modalities. Most patients had a normal course of follow-up. Conclusion: Interpretation of CBCT volumes is a skill every dentist must possess. When reviewing large-volume CBCT scans, the clinician should be able to distinguish pathology from normal anatomic variations within the skull base. The majority of clivus variations are asymptomatic and will remain undetected unless incidentally noted on radiographic examinations.

임상가를 위한 특집 1 - CBCT의 선택과 처방 (How to Choose and Use the CBCT)

  • 안창현
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.132-138
    • /
    • 2014
  • The emergence of Cone Beam Computed Tomography(CBCT) in the late 1990s represented an innovative advancement in the field of dental and maxillofacial radiology because it greatly reduced the radiation exposure to patients and offered 3D images easily. The 3D information generated by this technique brings the potential of improved diagnosis and treatment planning for a wide range of clinical applications in dentistry. The use of CBCT includes diagnosis and surgical assessment of the orofacial hard tissue lesions, dental implant treatment planning and postoperative evaluation, TMJ assessment, diagnosis of craniofacial fracture, orthodontics, endodontics, and so on. All CBCT examinations should be justified on an individualized needs. The clinical benefits to the patient for each CBCT scan must outweigh the potential risks associated with exposure to ionizing radiation. CBCT scans should be taken with initially obtained medical and dental histories of patients and a close clinical examination. CBCT should be considered as an imaging alternative of other conventional radiography in cases where the anatomical structures of interest may not be seen. The smallest possible field of view(FOV) and the lowest setting of tube current and scan time should be chosen, and the entire images scanned should be interpreted by a qualified expert.

Cone beam형 전산화단층영상에서 골의 형태와 밀도의 평가 (Evaluation of imaging reformation with cone beam computed tomography for the assessment of bone density and shape in mandible)

  • 홍상우;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. Materials and Methods: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. Results: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. Conclusion: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.

  • PDF

호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교 (Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom)

  • 김성은;원희수;홍주완;장남준;정우현;최병돈
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.123-130
    • /
    • 2016
  • 목 적 : Computerized imaging reference systems 동적팬텀을이용한 cone-beamcomputed tomography(CBCT) 영상과 four-dimensionalcomputed tomography(4DCT) 영상의 체적을 비교분석 하고자 한다. 대상 및 방법 : 동적팬텀 내에 직경 1, 2, 3 cm 노드를 각각 삽입하고, CT simulator와 TruebeamSTx X-ray Imaging system을 이용하여 4DCT 영상과 CBCT 영상을 얻었다. 4DCT 영상은 maximum intensity projection(MIP), minimum intensity projection(MinIP), 그리고 average intensity projection(AVG)영상으로 재구성 하고 노드의 체적은 Eclipse system의 CT ranger tool로 CT number를 설정하여 측정하였다. 결 과 : CBCT를 기준으로 노드1, 2, 3 cm의 체적을 비교하였을 때 4DCT의 MIP는 0.54~2.33, 5.16~8.06, 9.03~20.11 ml, MinIP는 0.00~1.48, 0.00~8.47, 1.42~24.85 ml, AVG는 0.00~1.17, 0.00~2.19, 0.04~3.35 ml의 차이를 보였다. 결 론 : 노드의 체적을 비교한 결과 CBCT 영상은 4DCT의 AVG 영상과 유사한 것으로 확인되었다.

  • PDF