• Title/Summary/Keyword: CAx

Search Result 33, Processing Time 0.019 seconds

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

Phonatory Caracteristics of Vwels and Resonant Consonants using the Electroglottography (전기성문파형검사를 이용한 모음과 공명 자음의 발성특성)

  • Choi, Seong-Hee;Nam, Do-Hyun;Lim, Jae-Yol;Lim, Sung-Eun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.133-140
    • /
    • 2004
  • Background and Objectives : Vowels and resonant including nasals and liquid are produced with vocal folds vibration have been used for voice therapy of hyperadduction patients. This study was conducted to investigate phonatory characteristics of vowels and resonant consonants through the EGG measures from Lx. Speech studio (Laryngograph Ltd, UK). Materials and Method : 7 male adults produced sustained vowel /a/, /i/, /u/, nasals /m/, /n/, /${\eta}$/and liquid /I/ and read the sentences (1nasals-liquid sentence, 1 non-nasals-liquid sentence) and tongue-tip trill and humming. Fx(Hz), Ox(%) were obtained of vowels, nasals, liquid and each of the posterior vowel /a/ of /ma/, /na/, /la/, /ha/ with same F0(around F#165Hz) and amplitude (75${\pm}$5db). And also DFx(Hz), DQx(%), CFx(%) and CAx(%) were obtained from reading two kinds of sentences. Results : Qx(%) was the highest in /u/ of vowels, and nasal/n/ of the resonant consonants and nasals-liquid sentence was higher Qx than non-nasals-liquid sentence but significant differences were not found. Qx(%) of the posterior vowel /a/ of nasal consonants/n/ was higher than in the isolated vowel/a/ and other posterior vowel of resonant consonants and fricatives /h/. Regularity or periodicity and higher Qx were observed in the nasals-liquid sentence than non-nasals-liquid sentence in graphs of QxFx & CFx produced by Quantiative analysis. In the nasalance score, /u/vowel was significant higher among the vowels and /I/ liquid was significant lower among the resonant consonants and nasals-liquid sentence is higher than non-nasals -liquid sentence. CQ(%) was not significantly correlated with nasalance(%). Conclusion : These findings might signify resonant phonation was not correlated with nasalance.

  • PDF

Preparation and Electrochemical Properties of Pr1-x (Sr, Ca)xCoO3 Cathode Materials for Zinc Air Batteries (아연공기전지용 Pr1-x (Sr, Ca)xCoO3 양극촉매 제조 및 전기화학적 특성)

  • Heo, Sang-Hun;Eom, Seung-Wook;Kim, Hyun-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.342-348
    • /
    • 2009
  • Zn/Air secondary batteries are high energy density type and environment-friendly. Also, they have safer properties than batteries of other type by low manufacturing cost and using the electrolyte solution. But, they have a weak concerning large output discharge. Oxygen evolution reaction(OER) and oxgen reduction reaction(ORR) in aqueous solution make a result of a decrease of cell efficiency and life span. Therefore, to minimize the voltage drop from between OCV and charge/discharge voltage is key point. The problem should be solved through developing catalysts of high efficiency. In this study, we synthesized $Pr_{1-x}(Sr,\;Ca)_x\;CoO_3$ powders by citric method and then measured physical characteristics of each powder by XRD, SEM, TGA etc. We examined its electrochemical properties by the cathodic polarization, anodic polarization and cyclic voltammogram. We achieved results that new catalysts showed better performances than existing $La_{1-x}Sr_xCoO_3$, $La_{1-x}Ca_xCoO_3$, ect. catalysts prepared in our lab.