• Title/Summary/Keyword: CANDU reactor

Search Result 208, Processing Time 0.026 seconds

CURRENT STATUS OF INTEGRITY ASSESSMENT BY SIPPING SYSTEM OF SPENT FUEL BUNDLES IRRADIATED IN CANDU REACTOR

  • Park, Jong-Youl;Shim, Moon-Soo;Lee, Jong-Hyeon
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.875-882
    • /
    • 2014
  • In terms of safety and the efficient management of spent fuel storage, detecting failed fuel is one of the most important tasks in a CANada Deuterium Uranium (CANDU) reactor operation. It has been successfully demonstrated that in a CANDU reactor, on-power failed fuel detection and location systems, along with alarm area gamma monitors, can detect and locate defective and suspect fuel bundles before discharging them from the reactor to the spent fuel storage bay. In the reception bay, however, only visual inspection has been used to identify suspect bundles. Gaseous fission product and delayed neutron monitoring systems cannot precisely distinguish failed fuel elements from each fuel bundle. This study reports the use of a sipping system in a CANDU reactor for the integrity assessment of spent fuel bundles. The integrity assessment of spent fuel bundles using this sipping system has shown promise as a nondestructive test for detecting a defective fuel bundle in a CANDU reactor.

THE IMPACT OF POWER COEFFICIENT OF REACTIVITY ON CANDU 6 REACTORS

  • Kastanya, D.;Boyle, S.;Hopwood, J.;Park, Joo Hwan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.573-580
    • /
    • 2013
  • The combined effects of reactivity coefficients, along with other core nuclear characteristics, determine reactor core behavior in normal operation and accident conditions. The Power Coefficient of Reactivity (PCR) is an aggregate indicator representing the change in reactor core reactivity per unit change in reactor power. It is an integral quantity which captures the contributions of the fuel temperature, coolant void, and coolant temperature reactivity feedbacks. All nuclear reactor designs provide a balance between their inherent nuclear characteristics and the engineered reactivity control features, to ensure that changes in reactivity under all operating conditions are maintained within a safe range. The $CANDU^{(R)}$ reactor design takes advantage of its inherent nuclear characteristics, namely a small magnitude of reactivity coefficients, minimal excess reactivity, and very long prompt neutron lifetime, to mitigate the demand on the engineered systems for controlling reactivity and responding to accidents. In particular, CANDU reactors have always taken advantage of the small value of the PCR associated with their design characteristics, such that the overall design and safety characteristics of the reactor are not sensitive to the value of the PCR. For other reactor design concepts a PCR which is both large and negative is an important aspect in the design of their engineered systems for controlling reactivity. It will be demonstrated that during Loss of Regulation Control (LORC) and Large Break Loss of Coolant Accident (LBLOCA) events, the impact of variations in power coefficient, including a hypothesized larger than estimated PCR, has no safety-significance for CANDU reactor design. Since the CANDU 6 PCR is small, variations in the range of values for PCR on the performance or safety of the reactor are not significant.

Effect of DUPIC Cycle on CANDU Reactor Safety Parameters

  • Mohamed, Nader M.A.;Badawi, Alya
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1109-1119
    • /
    • 2016
  • Although, the direct use of spent pressurized water reactor (PWR) fuel in CANda Deuterium Uranium (CANDU) reactors (DUPIC) cycle is still under investigation, DUPIC cycle is a promising method for uranium utilization improvement, for reduction of high level nuclear waste, and for high degree of proliferation resistance. This paper focuses on the effect of DUPIC cycle on CANDU reactor safety parameters. MCNP6 was used for lattice cell simulation of a typical 3,411 MWth PWR fueled by $UO_2$ enriched to 4.5w/o U-235 to calculate the spent fuel inventories after a burnup of 51.7 MWd/kgU. The code was also used to simulate the lattice cell of CANDU-6 reactor fueled with spent fuel after its fabrication into the standard 37-element fuel bundle. It is assumed a 5-year cooling time between the spent fuel discharges from the PWR to the loading into the CANDU-6. The simulation was carried out to calculate the burnup and the effect of DUPIC fuel on: (1) the power distribution amongst the fuel elements of the bundle; (2) the coolant void reactivity; and (3) the reactor point-kinetics parameters.

A Study on Severe Accident Management Capabilities and Strategies for CANDU Reactor (가압중수로형원전의 중대사고 대응능력 연구)

  • Choi, Young;Park, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.160-165
    • /
    • 2014
  • The realistic cases causing severe core damage should be analyzed and arranged systematically for preparing an accident management of the specific nuclear power plant. The objective of this paper is to establish basic technical information for reactor safety and reactor building integrity management strategies in CANDU reactor severe accident. For the development of severe accident management strategies, plant specific features and behaviors must be studied by detailed analysis works. This analysis scope will serve to cover overall methods and analyzing results to understand the reactor building integrity status in the most likely severe accident sequences that could occur at CANDU reactor. Also analysis results could help prevent or mitigate severe accidents for the identification of any plant specific vulnerabilities to severe accidents using the probabilistic safety assessment (PSA) quantified results.

Transient Analysis of the CANDU-9 480/SEU Reactor (CANDU-9 480/ SEU 원자로의 과도변화해석)

  • J. C. Shin;Park, J. H.;K. N. Han;H. C. Suk
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.687-700
    • /
    • 1995
  • The thermal-hydraulic transient analysis of the proposed CANDU-9 plant was peformed. Several major transients ore analyzed if they meet the heat transport system design requirements. The proposed heat transport system configuration and the preliminary sizes of system equipment are justified by analysis in terms of the fuel integrity and the high system pressure limit during transients. The compliance with AECB R-77 requirements for CANDU-9 reactor was estimated. The analysis results showed that for each postulated accident the peak pressure values in the reactor headers are within the acceptance criteria given in ASME code requirements and the fuel overheating is prevented. One pump start-up during the reactor start-up operation was analyzed to investigate the How reversal through the fuel channel, which is specific in the proposed CANDU-9 plant.

  • PDF

Nuclear Characteristics of a New(PWR-PHWR) Fuel Cycle (PWR-PHWR 핵연료 주기의 핵적 특성)

  • Jae Woong Song;Chang Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.185-192
    • /
    • 1985
  • The fissile content of PWR spent fuel is higher than that of natural uranium which is normal fuel for CANDU type reactor. Investigated are the concepts of PWR spent fuel utilization in CANDU type reactor to diversify uranium resource and partially to solve storage problems of PWR spent fuel being gradually accumulated. Nuclear characteristics of uranium-plutonium mixed oxide fuel loaded in CANDU type reactor are analysed using the WIMS/D computer code. In this study, analyses are solely carried out upon the current CANDU type reactor design without changingany reactivity control devices.

  • PDF

Development of the Regulatory Guidelines for Continued Operation of CANDU Reactor in Korea (CANDU형 원전 계속운전 평가지침서 개발)

  • Choi, Young-Hwan;Kim, Hong-Key
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.4
    • /
    • pp.495-499
    • /
    • 2010
  • In this paper, the regulatory guidelines for the continued operation of the CANDU reactor in Korea were introduced. Wolsong Unit 1, which is a CANDU 600 reactor in Korea, will reach its design life of 30 years in 2012. A licensee who wants to operate a nuclear power plant beyond its design life should submit reports of periodic safety reviews (PSRs) conducted on the basis of 11 safety factors. In addition, the licensee should provide the following: (1) scoping and screening results for aging management, (2) aging management program, (3) TLAA, including the continued operation term, (4) operation-experience feedback, and (5) important safety-research results. In this study, 54 regulatory guidelines for the five above-mentioned items for the CANDU reactor in Korea were developed.

Neutronic study of utilization of discrete thorium-uranium fuel pins in CANDU-6 reactor

  • Deng, Nianbiao;Yu, Tao;Xie, Jinsen;Chen, Zhenping;Xie, Qin;Zhao, Pengcheng;Liu, Zijing;Zeng, Wenjie
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.377-383
    • /
    • 2019
  • Targeting at simulating the application of thorium-uranium (TU) fuel in the CANDU-6 reactor, this paper analyzes the process using the code DRAGON/DONJON where the discrete TU fuel pins are applied in the CANDU-6 reactor under the time-average equilibrium refueling. The results show that the coolant void reactivity of the assembly analyzed in this paper is lower than that of 37-element bundle cell with natural uranium and 37-element bundle cell with mixed TU fuel pins; that the max time-average channel/bundle power of the core meets the limits - less than 6700kW/860 kW; that the fuel conversion ratio is higher than that of the CANDU-6 reactor with natural uranium; and that the exit burnup increases to 13400 MWd/tU. Thus, the simulation in this paper with the fuel in the 37-element bundle cell using discrete TU fuel pins can be considered to be applied in CANDU-6 reactor with adequate modifications of the core structure and operating modes.

Assessments of RELAP5/MOD3.2 and RELAP5/CANDU in a Reactor Inlet Header Break Experiment B9401 of RD-14M

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.426-441
    • /
    • 2003
  • A reactor inlet header break experiment, B9401, performed in the RD-14M multi channel test facility was analyzed using RELAP5/MOD3.2 and RELAP5/CANDU[1]. The RELAP5 has been developed for the use in the analysis of the transient behavior of the pressurized water reactor. A recent study showed that the RELAP5 could be feasible even for the simulation of the thermal hydraulic behavior of CANDU reactors. However, some deficiencies in the prediction of fuel sheath temperature and transient behavior in athe headers were identified in the RELAP5 assessments. The RELAP5/CANDU has been developing to resolve the deficiencies in the RELAP5 and to improve the predictability of the thermal-hydraulic behaviors of the CANDU reactors. In the RELAP5/CANDU, critical heat flux model, horizontal flow regime map, heat transfer model in horizontal channel, etc. were modified or added to the RELAP5/MOD3.2. This study aims to identify the applicability of both codes, in particular, in the multi-channel simulation of the CANDU reactors. The RELAP5/MOD3.2 and the RELAP5/CANDU analyses demonstrate the code's capability to predict reasonably the major phenomena occurred during the transient. The thermal-hydraulic behaviors of both codes are almost identical, however, the RELAP5/CANDU predicts better the heater sheath temperature than the RELAP5/MOD3.2. Pressure differences between headers govern the flow characteristics through the heated sections, particularly after the ECI. In determining header pressure, there are many uncertainties arisen from the complicated effects including steady state pressure distribution. Therefore, it would be concluded that further works are required to reduce these uncertainties, and consequently predict appropriately thermal-hydraulic behaviors in the reactor coolant system during LOCA analyses.

A Three-Dimensional Operational Transient Simulation of the CANDU Core with Typical Reactor Regulating System

  • Yeom, Choong-Sub;Kim, Hyun-Dae;Park, Kyung-Seok;Park, Jong-Woon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.500-505
    • /
    • 1995
  • This paper describes the results of simulation of a CANDU operational transient problem (re-startup after short shutdown) using the Coupled Reactor Kinetics(CRKIN) code developed previously with CANDU Reactor Regulating System(RRS) logic. The performance in the simulation is focused on investigating the behaviours of neutron power and regulating devices in accordance with the changes of xenon concentration following the operation of the RRS.

  • PDF