• Title/Summary/Keyword: CAM Software

Search Result 283, Processing Time 0.026 seconds

A Feature Based Modeling System for the Design of Welded Plate Construction (용접판 구조물의 설계를 위한 Feature 기반 모델링 시스템)

  • Kim, Dong-Won;Yang, Sung-Mo;Choi, Jin-Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.4
    • /
    • pp.30-41
    • /
    • 1993
  • Developed in this paper is a feature based modeling system for the design of welded plat construction(WPC) which is composed of flat or bended plates represented as reference plane with a constant thickness. First, the necessity and the characteristics of the modeing system for WPC as compared with the assembly of mechanical parts are investigated. Secondly, feature library for the assembly of WPC is shown which contains several types of features like joint feature, groove feature, material feature, and precision feature. Thirdly, the assembly procedures are presented which mainly consist of both the assembly transformation and the correct assembly checking. Fourthly, weld lines of the assembled WPC are defined so that those can be used in the process planning or the manufacturing stage. Finally, a prototype by a geometric modeling software Pro/Engineer, a graphic software GL(Graphic Library), and C language on a CAD workstation IRIS.

  • PDF

Development of ISO14649 Compliant CNC Milling Machine Operated by STEP-NC in XML Format

    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.5
    • /
    • pp.27-33
    • /
    • 2003
  • G-code, another name of ISO6983, has been a popular commanding language for operating machine tools. This G-code, however, limits the usage of today's fast evolving high-performance hardware. For intelligent machines, the communications between machine and CAD/CAM departments become important, but the loss of information during generating G-code makes the production department isolated. The new standard for operating machine tools, named STEP-NC is just about to be standardized as ISO14649. As this new standard stores CAD/CAM information as well as operation commands of CNC machines, and this characteristic makes this machine able to exchange information with other departments. In this research, the new CNC machine operated by STEP-NC was built and tested. Unlike other prototypes of STEP-NC milling machines, this system uses the STEP-NC file in XML file form as data input. This machine loads information from XML file and deals with XML file structure. It is possible for this machine to exchange information to other databases using XML. The STEP-NC milling machines in this research loads information from the XML file, makes tool paths for two5D features with information of STEP-NC, and machines automatically without making G-code. All software is programmed with Visual $C^{++}$, and the milling machine is built with table milling machine, step motors, and motion control board for PC that can be directly controlled by Visual $C^{++}$ commands. All software and hardware modules are independent from each other; it allows convenient substitution and expansion of the milling machine. Example 1 in ISO14649-11 having the full geometry and machining information and example 2 having only the geometry and tool information were used to test the automatic machining capability of this system.

Technology Trends on Structural Analysis Software in Aerospace Industry (항공우주산업 구조해석 소프트웨어 기술동향)

  • Lim, Jae-Hyuk;Kim, Kyung-Won;Kim, Sun-Won;Hwang, Do-Soon
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.7 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • Computer Aided Engineering(CAE) technology as well as Design(CAD) and Manufacturing(CAM) have been widely adopted in the aerospace industry in order to develop the structure of airplanes, satellites and launch vehicles. Among them, CAE softwares based on finite element methods such as NASTRAN, ABAQUS and ANSYS have gained many engineers' interest in various industries such as automobiles, civils, aircraft and spacecraft. The softwares usually consist of several modules: Static, Dynamic, Vibration, Impact etc. that make analysis specific to meet the design goals of the structure systems. Recent enhancement in the computer hardwares and numerical algorithms enables us to perform complex analysis like multi-physics, optimum design. Also, they make it possible to deal with a large scale problem easily. This paper reviews structural analysis softwares in aerospace industry and gives a summary on its recent development.

  • PDF

Evaluation of biogeneric design techniques with CEREC CAD/CAM system

  • Arslan, Yeliz;Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Tamam, Evsen;Yilmaz, Handan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.431-436
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate occlusal contacts generated by 3 different biogeneric design modes (individual (BI), copy (BC), reference (BR)) of CEREC software and to assess the designs subjectively. MATERIALS AND METHODS. Ten pairs of maxillary and mandibular casts were obtained from full dentate individuals. Gypsum cast contacts were quantified with articulating paper and digital impressions were taken. Then, all ceramic crown preparation was performed on the left first molar teeth and digital impressions of prepared teeth were made. BI, BC, and BR crowns were designed. Occlusal images of designs including occlusal contacts were superimposed on the gypsum cast images and corresponding contacts were determined. Three designs were evaluated by the students. RESULTS. The results of the study revealed that there was significant difference among the number of contacts of gypsum cast and digital models (P<.05). The comparison of the percentage of virtual contacts of three crown designs which were identical to the contacts of original gypsum cast revealed that BI and BR designs showed significantly higher percentages of identical contacts compared with BC design (P<.05). Subjective assessment revealed that students generally found BI designs and BR designs natural regarding naturalness of fissure morphology and cusp shape and cusp tip position. For general occlusal morphology, student groups generally found BI design "too strong" or "perfect", BC design "too weak", and BR design "perfect". CONCLUSION. On a prepared tooth, three different biogeneric design modes of a CAD/CAM software reveals different crown designs regarding occlusal contacts and morphology.

In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment

  • Aladag, Akin;Oguz, Didem;Comlekoglu, Muharrem Erhan;Akan, Ender
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.120-127
    • /
    • 2019
  • PURPOSE. To determine wear amount of single molar crowns, made from four different restoratives, and opposing natural teeth through computerized fabrication techniques using 3D image alignment. MATERIALS AND METHODS. A total of 24 single crowns (N = 24 patients, age range: 18 - 50) were made from lithium disilicate (IPS E-max CAD), lithium silicate and zirconia based (Vita Suprinity CAD), resin matrix ceramic material (Cerasmart, GC), and dual matrix (Vita Enamic CAD) blocks. After digital impressions (Cerec 3D Bluecam, DentsplySirona), the crowns were designed and manufactured (Cerec 3, DentsplySirona). A dualcuring resin cement was used for cementation (Variolink Esthetic DC, Ivoclar). Then, measurement and recording of crowns and the opposing enamel surfaces with the intraoral scanner were made as well as at the third and sixth month follow-ups. All measurements were superimposed with a software (David-Laserscanner, V3.10.4). Volume loss due to wear was calculated from baseline to follow-up periods with Siemens Unigraphics NX 10 software. Statistical analysis was accomplished by Repeated Measures for ANOVA (SPSS 21) at = .05 significance level. RESULTS. After 6 months, insignificant differences of the glass matrix and resin matrix materials for restoration/enamel wear were observed (P>.05). While there were no significant differences between the glass matrix groups (P>.05), significant differences between the resin matrix group materials (P<.05) were obtained. Although Cerasmart and Enamic were both resin matrix based, they exhibited different wear characteristics. CONCLUSION. Glass matrix materials showed less wear both on their own and opposing enamel surfaces than resin matrix ceramic materials.

Distracted Driver Detection and Characteristic Area Localization by Combining CAM-Based Hierarchical and Horizontal Classification Models (CAM 기반의 계층적 및 수평적 분류 모델을 결합한 운전자 부주의 검출 및 특징 영역 지역화)

  • Go, Sooyeon;Choi, Yeongwoo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.10 no.11
    • /
    • pp.439-448
    • /
    • 2021
  • Driver negligence accounts for the largest proportion of the causes of traffic accidents, and research to detect them is continuously being conducted. This paper proposes a method to accurately detect a distracted driver and localize the most characteristic parts of the driver. The proposed method hierarchically constructs a CNN basic model that classifies 10 classes based on CAM in order to detect driver distration and 4 subclass models for detailed classification of classes having a confusing or common feature area in this model. The classification result output from each model can be considered as a new feature indicating the degree of matching with the CNN feature maps, and the accuracy of classification is improved by horizontally combining and learning them. In addition, by combining the heat map results reflecting the classification results of the basic and detailed classification models, the characteristic areas of attention in the image are found. The proposed method obtained an accuracy of 95.14% in an experiment using the State Farm data set, which is 2.94% higher than the 92.2%, which is the highest accuracy among the results using this data set. Also, it was confirmed by the experiment that more meaningful and accurate attention areas were found than the results of the attention area found when only the basic model was used.

Mobile Interactive Broadcasting Learning Solution Study on Development of Education (모바일 양방향 화상 교육시스템 개발에 관한 연구)

  • Kim, Tai-Dal;Lee, Byung-Kwon
    • Journal of Internet Computing and Services
    • /
    • v.13 no.1
    • /
    • pp.57-63
    • /
    • 2012
  • Recently, Development of high-speed internet networks can be a real-time video conference system. SD-quality still images using the software codec system exists, and two-way system with mobile systems, but in most video only send and receive video system. In this study, HD web-cam using the two-way live broadcasts simultaneously in the education system and the mobile system has developed an audible system. In the study using the H.264 standard video compression techniques were applied to high-bandwidth compression technology, smart phones, to develop a streaming server for broadcasting were applied. Video sharing, document, web-sharing was made possible in real time. In addition, the private IP for WiFi zone, available anytime, anywhere that can be converted to a public IP technology, IP tunneling technology applied.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system (CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가)

  • Kim, So-Ri;Kim, Chong-Myeong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system

  • Lee, Jeong-Yol;Choi, Sang-Jin;Kim, Min-Soo;Kim, Ha-Young;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.118-125
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS. Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope ($AXIO^{(R)}$, Carl Zeiss, Rochester, NY) and software (I-$solution^{(R)}$, IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (${\alpha}$=.05). RESULTS. There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 ${\mu}m$. CONCLUSION. Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit.