• Title/Summary/Keyword: CALPUFF

Search Result 47, Processing Time 0.03 seconds

A Case Study on Health Impact Assessment of Hazardous Air Pollutants in Industrial Complex Development Plan (산업단지 계획 시 유해대기오염물질에 대한 건강영향평가 사례 연구)

  • Kim, Sang-Mok;Son, Eun-Seong;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.616-625
    • /
    • 2019
  • Health impact assessment is implemented within the Environmental impact assessment for the purpose of minimizing health damage by predicting the impact on human health following implementation of the development project. In health impact assessment, manual revision is required due to the lack of consistency in the method of estimating hazardous air pollutants emissions. This study estimated the emissions by calculating the emissions of hazardous air pollutants based on the actual industrial complex development cases and completed health impact assessments. As a result of risk assessment based on exposure concentration using CALPUFF model, the risk assessment results were different for each of the emission estimation methods, and manual improvement on the emission estimation method is needed.

Charaterization of Odor from Cement Kiln (시멘트공장 소성로 악취 배출특성)

  • Kim, Ji-Hyun;Lim, Hee-Ah;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.694-703
    • /
    • 2017
  • Many residents living near the cement factories are facing unpleasant odors. Thus, various efforts have been attempted to reduce the emission of odorous compounds from the cement manufacturing processes. This study focused on analysis of Acetaldehyde and their dispersion in vicinity of the residential area using theoretical calculation such as numerical simulation and dispersion model. The most significant odor species was acetaldehyde indicating 2 ppb at the test point, and the estimated concentration was similar to the value by Calpuff calculation. The modelling work revealed the emission source of the factory to influence the test site.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(I) - Effect zone of environmental pneumoconiosis and fugitive dust - (대구 안심연료단지 환경오염물질 노출 평가(I) - 환경성 진폐증 및 비산먼지 영향권역 -)

  • Jung, Jong-Hyeon;Oh, In-Bo;Phee, Young-Gyu;Nam, Mi-Ran;Hwang, Mi-Kyoung;Bang, Jin-Hee;Jeon, Soo-Bin;Lee, Sang-sup;Yu, Seung-do;KimS, Byung-Seok;Yoo, Seok-Ju;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.366-379
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter(PM) pollution and its effect on health of residents living near Ansim Briquette Fuel Complex in Daegu metropolitan region. Methods: The California Puff(CALPUFF) dispersion model, version 5.8, which can estimate the dispersion direction and range of airborn $PM_{10}$ was used to determine the possible areas affected by $PM_{10}$ pollutants emitted from Ansim briquette fuel complex. The CALPUFF modeling with 200 m grid-cell resolution was performed based on $PM_{10}$ emissions estimated from the amount of coal consumption in the fuel complex for four months in 2012. The Weather Research and Forecasting(WRF) fields were processed using CALMET to produce CALPUFF-ready meteorological inputs. Also, the distance from Ansim Briquette Fuel Complex to the residence of each environmental pneumoconiosis patient was analyzed. In addition, the affecting region of the pollutants emitted from briquette factories in Ansim Briquette Fuel Complex was determined. Results: CALPUFF modeling results showed that the highest concentrations of $PM_{10}$ were found near around the fuel complex. The modeled $PM_{10}$ distributions were characterized by significant decreases in concentration with distance from the complex. Seasonally, the highest concentration of $45{\mu}g/m^3$ was calculated in October which was mostly due to the distinct variation of amount of emission. Additional modeling with the maximum $PM_{10}$ emission of about 88 tons per year in 1986 showed that the highest concentration in October was nearly increased by 8 times than the concentration modeled with emission of 2010. As a result of medical examination and interviews for the residents in Ansim Briquette Fuel Complex and its surroundings, 8 environmental pneumoconiosis patients were found. These patients do not have occupational exposure and history. These patients have lived 0.3~1.1 km area in Ansim Briquette Fuel Complex and its surroundings. Conclusions: Airborne particles emitted from Ansim Briquette Fuel Complex can contribute to significant increase in $PM_{10}$ concentration in residential areas near around the complex. Especially, the residents near fuel complex may exposed to the pollutants emitted from the factories in Ansim Briquette Fuel Complex.

Environmental Exposure to Tobacco-specific Nitrosamines in an Area Near a Fertilizer Plant (비료제조공장 인근 지역의 담배특이니트로사민 환경 노출)

  • Ha, Jae-Na;Yoon, Mi-Ra;Chang, Jun Young;Koh, Dohyun;Shin, Ho-Sang;Kim, Suhyang;Lee, Chul-Woo;Lee, Bo-Eun;Kim, Jeong-Soo
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.398-409
    • /
    • 2020
  • Objectives: This study aimed to evaluate environmental exposure to tobacco-specific nitrosamines (TSNAs) by conducting an analysis of the concentration of TSNAs in deposited dust collected from a fertilizer plant and the surrounding village, a simulation of high-temperature drying of tobacco waste, and CALPUFF modeling. Methods: The raw materials of the products, deposited dust (inside and outside the plant and residential area), soil, and wastewater were sampled and the TSNA concentrations were analyzed by LC-MS/MS. As the plant was closed down before the investigation, simulation tests were conducted to confirm the substances discharged during high-temperature (300℃) drying of tobacco waste. CALPUFF modeling was performed to identify the area of influence due to exposure to TSNAs. Results: TSNAs were detected in organic fertilizers estimated to contain tobacco waste, deposited dust, and soil collected from inside and outside the plant. N'-nitrosonornicotine (NNN), 4-(methylnitrosoamino)-1-(3-pyridyl)-1-butanone (NNK), and N'-nitrosoanatabine (NAT) components were detected in five of 15 deposited dust samples collected from the residential area around the plant, while TSNAs were not detected in the five sampling points in the control area. Also, the simulation test for the high temperature drying of tobacco waste found emissions of TSNAs. The CALPUFF modeling results showed that the survey area was likely to be included in the area of influence of TSNA emissions from the plant. Conclusions: It is estimated that harmful tobacco ingredients such as TSNAs were dispersed in nearby areas due to the illegal use of tobacco waste as a raw material to produce organic fertilizers at the plant. These findings assume that the residents have been exposed to TSNAs and suggest that the need for the establishment of measures to manage environmental health.

A Impact Analysis of Air Quality by Air Pollution Control Facilities Improvement on Point Source Pollution (점오염원의 대기오염방지시설 개선에 의한 대기질 영향 분석)

  • Jeon, Byeong-Geun;Lee, Sang-Houck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2876-2882
    • /
    • 2015
  • The object of this study is to identify changes in air pollution in the maximum ground level concentration and the surrounding area when air pollution control facilities are improved in the thermal power plants. The effects of improved facilities are analyzed by comparing air quality after applying improved air pollution control facilities. For prediction of air quality, the change of wind field can be represented with movement of Puff and CALPUFF Model, air pollution diffusion models which can implement abnormal conditions. Major air pollutants of thermal power plants such as $SO_2$, $NO_2$, and $PM_{10}$ are selected as prediction items. That results show that improvement of air pollution control facilities is significantly effective in reduction of air pollution of $SO_2$ and $NO_2$ in the maximum ground level concentration and areas around of thermal power plants. In the case of $PM_{10}$, it is found that the effect of reduction in pollution is high in the maximum ground level concentration, but the effect of reduction in air pollution is somewhat low in the area around of the thermal power plant.

Health and Environmental Risk Assessment of Pollutants in Pohang (포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로-)

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2719-2726
    • /
    • 2010
  • The purpose of this study was to investigate the scientific basic grounds for the assessment of health and environmental diseases resulting from air pollutants in Pohang. For this study, we investigated pollutants, weather characteristics and concentration distribution of fine particles ($PM_10$) yearly and each season, using data from Air Quality Monitoring Stations. The properties of concentration distribution and seasonal fluctuation of $PM_10$ were studied qualitatively and quantitatively using CALPUFF, air dispersion model. The average concentration of $PM_10$ for each season was spring($75.7{\mu}g/m^3$)>summer($56.8{\mu}g/m^3$)>winter($53.6{\mu}g/m^3$)>fall( $52.7{\mu}g/m^3$). In the case of spring, high concentrations appear due to the Asian dust frequently occurring. The contributions of $PM_10$ classified by the types of pollution source in Pohang were point source 62%>mobile source 33%>area source 5%. An important point is that 97% of emissions were produced from the iron manufacture in steel industry. Therefore, it is necessary to control the emission sources of pollutants and to construct an observation system at Pohang steel industrial complex from now on. It’s time to control the risk factors for health and environmental disease to protect the health of resident in Pohang and its neighboring areas.

An Air Dispersion Modeling of the Dense Gas (Dense gas의 대기 확산 모델링)

  • 김아름;구윤서;윤희영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.393-394
    • /
    • 2002
  • 현대 산업 사회의 급속한 발전으로 인해 대기 중에는 다양한 오염원을 통해서 많은 오염물질이 배출됨에 따라 이를 평가하고 방지할 대책이 필요하게 되었다. 이러한 대책 중의 하나로 배출원에서 배출되는 오염물질의 경로 및 발생량을 예측하는 방법이 있는데, 대기 상에 배출되는 오염물질의 농도를 예측할 경우 보통 대기 확산 모델링을 통하여 배출원 주변의 오염물질 확산 및 농도값을 산정한다. 현재 국내에서는 주로 가우시안 확산 모델인 ISC, CALPUFF 모델 등을 사용하여 모델링을 계산하게 된다. (중략)

  • PDF

A Case Study on the Air Quality Impact Assessment for the Large Scale Urban Development (대규모 도시개발사업에 대한 대기질 평가 사례 연구)

  • Kim, Sang-Mok;Lee, Sang-Hun;Park, Keun-Hyoung;Woo, Jae-Kyun;Koo, Youn-Seo;Kim, Sung-Tae;Han, Jin-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.381-391
    • /
    • 2007
  • The air quality modeling was carried out to assess the impact of air quality for large scale urban development. The site for the assessment is Multi-fuctional Administrative City which locates in Yeongi-gun, Chungcheongnam-do and estimated population in 2030 is 500,000. Two automatic weather monitoring stations were installed to monitor the meteorological variables for a year and upper air meteorological parameters were measured using radiosonde for 5 days with 4 hours interval in every season. The air quality of standard air pollutants were also measured for 5 days continuously in every season. The results of wind field analysis based on the site measurements and CALMET modeling showed that the valley and mountain winds were prevailed when the sypnotic wind was weak. It also showed that wind speed and directions were highly space-variable within the site basin. The variable wind characteristics implies that the Gaussian dispersion model such ISC3 and AERMOD are not appropriate and the unsteady-sate Lagrangian model such as CALPUFF is preferable. CALPUFF model was applied to assess air quality impact of new sources. The new sources were those for individual and group heating facilities as well as the traffic increases. The results showed that the estimated concentrations of CO and $SO_2$ pollutants by summing the impact concentration of new sources by the dispersion model and the ambient air concentrations by the site measurements were acceptable but those of PM-10 and $NO_2$ would violate ambient air quality standards at several locations due to high ambient air concentrations. It is recommended that the emission reductions near the site should be enforced to improve the ambient air quality.