• Title/Summary/Keyword: CAD/CAM 수복

Search Result 160, Processing Time 0.024 seconds

Full-mouth rehabilitation with pressed ceramic technique using provisional restorations (Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례)

  • Roh, Hyun-Sik;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • With the introduction of dental implants, restoration of missing teeth with conventional fixed or removable partial dentures is being replaced with implants. Especially, with young patients, not only longevity but also esthetic factors need to be considered. Implant restorations provide long-term success functionally but, esthetic complications such as, marginal exposure due to gingival recession, loss of the papilla and dark color of metal abutments may occur. Recently, zirconia restorations with CAD/CAM technology provide functional, biocompatible and esthetic restorations possible. All-ceramic restorations using the pressed ceramic technique show better fracture toughness values than those of the conventional porcelain veneering technique. Pressed ceramic technique creates the veneer design in wax and the lost wax technique is used to create the restoration. The final contour of the restoration may be controlled during wax-up. A 22-year old female patient was restored with dental implants and zirconia restorations using the pressed ceramic technique presenting short-term but optimistic prognosis.

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

디지털 가이드 시스템과 사전 제작된 임플란트 상부보철물을 이용한 전치부의 임플란트 수복 : 증례보고

  • Choi, Yongkwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.24-32
    • /
    • 2021
  • Dental implant have been in use for a long time to restore at missing tooth. But, To place dental implant at good position very is difficult. Improperly positioned dental implants make some problems to have a good function of dental implant. so, To place dental implant at accurate position is the most important step throughout the whole process. Digital guided system of dental implant is very useful to have a accurate position of dental implant and it makes upper restoration more esthetic and funcional.

Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report (비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례)

  • Ko, Chang Woo;Kim, Min-Ji;Yang, Hong-So;Park, Sang-Won;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

Fabrication of complete denture using CAD-based vertical dimension increase and monolithic disc: a case report (CAD를 이용한 수직 고경 증가와 monolithic disc를 사용한 총의치 수복 증례)

  • Hyeon, Kim;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.242-248
    • /
    • 2022
  • Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.