• Title/Summary/Keyword: C.C.M system

Search Result 6,087, Processing Time 0.045 seconds

A Study on the Performance-Improvement of TIG Welder with IGBT Inverter System. (IGBT 인버터제어 TIG용접기 성능개선에 관한 연구)

  • Lee, J.H.;Kim, J.M.;Kim, Y.C.;Won, C.Y.;Kim, G.S.;Kim, Y.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2155-2158
    • /
    • 1997
  • This paper describes the performance improvement of dc TIG (Tungsten Inert Gas) welder. The TIG welder consists of single phase full bridge IGBT inverter which incorporates the high frequency transformer, the boost converter for improving the input power factor, and the arc start system. The arc will be generated without fail even when the extension cable between the torch and the power source is 100m long. In addition, the arc start system with a short dc output voltage will generate less EMI noise than the traditional arc start system with a high frequency output voltage. To demonstrate the practical significance of the proposed methods, some simulation studies are presented.

  • PDF

Design of Automatic Assembly & Evaluation System for Phone Camera Module (폰 카메라 모듈 자동 조립.평가시스템 설계)

  • Song J.Y.;Lee C.W.;Ha T.W.;Jung Y.W.;Kim Y.G.;Lee M.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.71-72
    • /
    • 2006
  • In this study, automatic assembly and evaluation system fer phone camera module is conceptually designed. The designed core(Auto focus & UV curing, Image Test) equipments adopts a clustering mechanism and compactible structure using index table for minimum tact time. Using a ball screw actuator and absolute encoder in each axis, we can verifies the repeatability and position accuracy of system within ${\pm}3{\mu}m$. In result of simulation test, the proposed system is expected up to 30% in productivity than manual operation.

  • PDF

Hybrid Nanostructure-dependent Mechanical Properties and Crystallization Behaviors of Polypropylene/Clay Nanocomposites (폴리프로필렌/점토 나노복합체의 하이브리드 나노구조에 따른 기계적 성질 및 결정화거동 변화)

  • Choi, Ki-Woon;Lee, Han-Sup;Kang, Bok-Choon;Yang, Hoi-Chang
    • Polymer(Korea)
    • /
    • v.34 no.4
    • /
    • pp.294-299
    • /
    • 2010
  • Clay-loaded polypropylene (PP) nanocomposites were fabricated via melt-compounding of two molecular weight ($M_w$) PPs (140 and 410 kg/mol) and octadecylammine-treated clay (C18MMT), with the assistance of maleic anhydride-grafted PP(PP-MAH), respectively, at $170^{\circ}C$ and $190^{\circ}C$. At both melt-compounding temperatures, the low-$M_w$ PP tends to easily diffuse into silicate layers, especially in the presence of the mobile PP-MAH, resulting in a marked increase in silicate layer spacing (above 58 $\AA$), when compared to 27 $\AA$ in the high-$M_w$ PP-based system. Due to relatively lower melt-viscosity of the low-$M_w$ PP-based system, however, there existed quasi-stacked clay aggregates with a thickness of 60~80 nm, while the high-$M_w$ PP-based nanocomposites showed relatively homogeneous dispersion of clays. The different morphologies are mainly related to changes in the viscoelastic properties of PPs, dependent on the processing temperature and their $M_{w}s$. The slight differences in nanocomposites induce discernible crystallization and mechanical behaviors. High-$M_w$ PP-based nanocomposites containing 1~3 wt% C18MMT showed improvement in both tensile strength and modulus, while maintaining the inherent ductility of pure PP.

A Study on the Heat Transfer Enhancement by Trapezoid Rod in Impinging Jet System (충돌분류계에서 사다리형 로드를 이용한 열전달증진에 관한 연구)

  • Lim, T.S.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.565-571
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of air flow and heat transfer caused by trapezoid rods array in impinging air jet system. In this study, trapezoid rods have been set up on front of flat plate to act as a turbulence promoter. Local Nusselt numbers were determined as a function of three parameters: (a) the space from rods to heating surface(C=1, 2, 4mm), (b) the pitch between each rods(P=30, 40, 50mm), (c) the distance from nozzle exit to flat plate(H/B=2, 6, 10). And this research compared the above with the experiment without trapezoid rods. As a result, heat transfer performance was best under the condition of C=1mm and as the pitch is 30mm. In this case, maximum rate of heat transfer augmentation is about 1.9 times greater compared to that without trapezoid rods.

  • PDF

Parallel Implementation of Radon Transform on TMS320C80-based System (TMS320C80시스템에서 Radon 변환의 병렬 구현)

  • 송정호;성효경최흥문
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.727-730
    • /
    • 1998
  • In this paper, we propose an implementation of an efficient parallel Radon transform on TMS320C80-based system. For an N$\times$N SAR image, we can obtain O(NM/p) of the conventional parallel Radon transform, by representing the projection patterns in Radon space variables instead of the image space variables, and pipelining the algorithm, where p is the number of processors and M is the number of projection angles. Also, we can reduce the time for the dynamic load distribution among the nodes and the communication overheads of accessing the global memories, by pipelining the memory and processing operations by using tripple buffer structure. Experimental results show an efficient parallel Radon transform of speedup Sp=3.9 and efficiency E=97.5% for 256$\times$256 image, when implemented on TMS320C80 composed of four parallel slave processors with three memory blocks.

  • PDF

A Basic Study on the Performance CFD simulation of Road Snow-melting system by Ground Source Heat Pump (지열원 히트펌프를 이용한 도로융설시스템의 CFD 성능예측에 관한 기초연구)

  • Choi, Duk-In;Kim, Joong-Hun;Kim, Jin-Ho;Hwang, Kwang-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.23-28
    • /
    • 2010
  • Fluent ver.6.3 is used as CFD(Computational Fluid Dynamics) simulator to predict the performance of snow-melting system by geothermal pipes energy. As the results of this simulation, it is clearly shown that $50^{\circ}C$ of working fluid in to geothermal evaluated as more effect comparing to $45^{\circ}C$ of working fluid. The Surface temperature is come to $5^{\circ}C$ at 1m/s speed and $50^{\circ}C$ temperature of the working fluid.

Effect of Subzero Treatment on the Mechanical Properties and Damping Capacity of Austempered Ductile Cast Ironn (오스템퍼드 구상흑연주철의 기계적 성질 및 감쇠능에 미치는 서브제로처리의 영향)

  • Lee, K.H.;Kwon, M.K.;Kim, C.G.;Kang, C.Y.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.86-91
    • /
    • 2007
  • This study was investigated to know the effect of subzero treatment in austempered ductile cast iron. Retained austenite transformed to martensite by subzero treatment. With decreasing subzero treatment temperature, more volume fraction of retained austenite transformed to martensite and transformed to martensite above 30% by subzero treatment temperature at $-196^{\circ}C$. With decreasing subzero treatment temperature, the value of strength and hardness increased but the value of elongation and impact value decreased. In case of subzero treatment at $-196^{\circ}C$, hardness value increased about 18% and impact value decreased by above 20%. We could find that subzero treated specimens had a little of effect on the tensile properties but had very much effect on the hardness and value of the impact.

  • PDF

A Study on Regional Distribution of the Ground Effective Thermal Conductivity (지중 유효 열전도도의 지역별 분포)

  • Kong, Hyoung Jin;Kwon, Soon-Ki;Ji, Seung Gyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • Ground source heat pump(GSHP) systems is known as environmental friendly and energy saving. Especially a ground heat exchanger is an important unit that determines the thermal performance of a system and initial cost. In design phase of vertical GSHP system, it is recommended that the effective borehole thermal resistance, be determined from in-situ thermal response test. In this study, ground effective thermal conductivity was categorized by a region. As a result of the study, the ground thermal conductivity of national average was analyzed as 2.56 W/mK. The highest regional average of thermal conductivity is 2.68 W/mK in Seoul, and the lowest is 2.28 W/mK in Busan. Also, the thermal conductivity on the coast has been analyzed approximately 30% lower than the average.

A Basic Study on the Improvement of Construction Management Engineer Placement According to Workload (업무량에 따른 건설사업관리기술자 배치개선에 관한 기초연구)

  • Lee, Taick-Oun;Lee, Kook-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.114-115
    • /
    • 2018
  • Since the introduction of the C.M(Construction Management)system in the Basic Law of the Construction Industry in 1997, the recent arrangement of construction management engineers in public sector buildings has generally been based on architecture·civilengineering·machinery·landscaping, electricity, telecommunication, fire fighting by the number of M/M(Man and Month). In the field of engineers arrangement in each field, the arrangement of M/M according to the workload of architecture.civilengineering.machinery.landscaping and electricity is inadequate causing conflicts and C.M among construction management engineers. Therefore, this study aims at basic research that is used to identify the problems through the questionnaire and to prepare future improvement plans.

  • PDF

Investigated properties of Low temperature curing Ag Paste for Silicon Hetero-junction Solar Cell

  • Oh, Donghyun;Jeon, Minhan;Kang, Jiwoon;Shim, Gyeongbae;Park, Cheolmin;Lee, Youngseok;Kim, Hyunhoo;Yi, Junsin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.160-160
    • /
    • 2016
  • In this study, we applied the low temperature curing Ag paste to replace PVD System. The electrode formation of low temperature curing Ag paste for silicon Hetero-junction solar cells is important for improving device characteristics such as adhesion, contact resistance, fill factor and conversion efficiency. The low temperature curing Ag paste is composed various additives such as solvent, various organic materials, polymer, and binder. it depends on the curing temperature conditions. The adhesion of the low temperature curing Ag paste was decided by scratch test. The specific contact resistance was measured using the transmission line method. All of the Ag electrodes were experimented at various curing temperatures within the temperature range of $160^{\circ}C-240^{\circ}C$, at $20^{\circ}C$ intervals. The curing time was also changed by varying the conditions of 10-50min. In the optimum curing temperature $200^{\circ}C$ and for 20 min, the measured contact resistance is $19.61m{\Omega}cm^2$. Over temperature $240^{\circ}C$, confirmed bad contact characteristic. We obtained photovoltaic parameter of the industrial size such as Fill Factor (FF), current density (Jsc), open-circuit voltage (Voc) and convert efficiency of up to 76.2%, 38.1 mA/cm2, 646 mV and 18.3%, respectively.

  • PDF