• Title/Summary/Keyword: C-scan

Search Result 781, Processing Time 0.034 seconds

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

The Clinical Review of Superior Vena Cava Syndrome (상대정맥 증후군의 임상적 고찰)

  • Kang, Joung-Sun;Lee, Sam-Beom;Lee, Choong-Ki;Chung, Jin-Hong;Lee, Hyoung-Woo;Lee, Kwan-Ho;Hyun, Myung-Soo;Lee, Hyun-Woo;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.151-158
    • /
    • 1990
  • We reviewed 30 cases of superior vena cava syndrome in adult patients who were seen at the Yeungnam University Hospital from January 1985 to June 1990. The results were as follows : 1. The male-to-female ratio was 6.5:1, and the most patients were in the age group between the sixth and seventh decades. 2. The most common symptoms were dyspnea (87%) and followed by cough (63%), facial swelling (63%) and chest pain (44%) and the physical signs were dilated neck vein (97%), facial edema (93%) and facial flushing (45%) in order of frequency. 3. The simple chest x-ray findings were superior mediastinal widening (90%), right hilar mass (77%) and pleural effusion (31%). 4. Diagnosis was made by history and physical examination (100%), chest C-T scan (100%), simple chest x-ray (97%), bronchoscopy with biopsy (40%) and so on. 5. 21 cases of patients were confirmed by histology : 14 cases (46%) of bronchogenic ca. 4 cases (14%) of lymphoma, 3 cases (10%) of metastic lung ca. Of bronchogenic ca. small cell ca was 7 cases (23%), squamous cell ca, 5 cases (17%), and unclassified ca was 2 cases (6%). 6. In response of treatment, the clinical improvement was achieved in 18 cases with radiotherapy alone. 1 case with chemotherapy only, and 6 cases with radio-chemotherapy.

  • PDF

Risk factors for hospital admission in revisiting patients to the emergency department with abdominal pain

  • Bae, Jung Kwang;Kim, Hye Jin;Ryu, Seokyong;Choi, Seung Woon;Kang, Tae Kyung;Oh, Sung Chan;Cho, Suk Jin;Lee, Sun Hwa
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.679-686
    • /
    • 2018
  • Objective: The aim of this study was to identify the clinical characteristics and risk factors associated with the admission of patients in the emergency department (ED) within 30 days after discharge. Methods: A retrospective, observational study was conducted on adult patients presenting with abdominal pain to the ED of a single, urban, university hospital, between January 2014 and December 2015, who revisited the ED within 30 days after discharge. Data was collected on the emergency severity index level, time to contact doctors, physical examination, laboratory tests, use of computed tomography (CT), and patient disposition on revisitation. The primary outcome was hospital admission following an ED revisit in the 30-day period after the first visit. Results: During the study period, 19,480 patients visited the ED with the chief complaint of abdominal pain, and 13,577 were discharged. A total of 251 patients (1.29%) revisited the ED within 30 days, of which 89 were eligible for the study. The primary outcome was associated with not performing a CT scan on the initial visit and an increased C-reactive protein (CRP) value. Receiver operating characteristic curve analysis showed that a cut-off baseline CRP value of >0.35 mg/dL can predict the primary outcome with a sensitivity and specificity of 75% and 62.1%, respectively (area under the curve, 0.701; 95% confidence interval, 0.569-0.833; P=0.007). Conclusion: An increased CRP value and not performing abdominal CT were associated with a higher rate of admission following ED revisits of patients with abdominal pain. Future prospective studies on the role of abdominal CT imaging in patients presenting to the ED with abdominal pain will be needed.

Prediction of the Development of Pulmonary Fibrosis Using Serial Thin-Section CT and Clinical Features in Patients Discharged after Treatment for COVID-19 Pneumonia

  • Minhua Yu;Ying Liu;Dan Xu;Rongguo Zhang;Lan Lan;Haibo Xu
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.746-755
    • /
    • 2020
  • Objective: To identify predictors of pulmonary fibrosis development by combining follow-up thin-section CT findings and clinical features in patients discharged after treatment for COVID-19. Materials and Methods: This retrospective study involved 32 confirmed COVID-19 patients who were divided into two groups according to the evidence of fibrosis on their latest follow-up CT imaging. Clinical data and CT imaging features of all the patients in different stages were collected and analyzed for comparison. Results: The latest follow-up CT imaging showed fibrosis in 14 patients (male, 12; female, 2) and no fibrosis in 18 patients (male, 10; female, 8). Compared with the non-fibrosis group, the fibrosis group was older (median age: 54.0 years vs. 37.0 years, p = 0.008), and the median levels of C-reactive protein (53.4 mg/L vs. 10.0 mg/L, p = 0.002) and interleukin-6 (79.7 pg/L vs. 11.2 pg/L, p = 0.04) were also higher. The fibrosis group had a longer-term of hospitalization (19.5 days vs. 10.0 days, p = 0.001), pulsed steroid therapy (11.0 days vs. 5.0 days, p < 0.001), and antiviral therapy (12.0 days vs. 6.5 days, p = 0.012). More patients on the worst-state CT scan had an irregular interface (59.4% vs. 34.4%, p = 0.045) and a parenchymal band (71.9% vs. 28.1%, p < 0.001). On initial CT imaging, the irregular interface (57.1%) and parenchymal band (50.0%) were more common in the fibrosis group. On the worst-state CT imaging, interstitial thickening (78.6%), air bronchogram (57.1%), irregular interface (85.7%), coarse reticular pattern (28.6%), parenchymal band (92.9%), and pleural effusion (42.9%) were more common in the fibrosis group. Conclusion: Fibrosis was more likely to develop in patients with severe clinical conditions, especially in patients with high inflammatory indicators. Interstitial thickening, irregular interface, coarse reticular pattern, and parenchymal band manifested in the process of the disease may be predictors of pulmonary fibrosis. Irregular interface and parenchymal band could predict the formation of pulmonary fibrosis early.

Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea (식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석)

  • Hur, Won-Joo;Choi, Young-Min;Lee, Hyung-Sik;Kim, Jeung-Kee;Kim, Il-Han;Lee, Ho-Jun;Lee, Kyu-Chan;Kim, Jung-Soo;Chun, Mi-Son;Kim, Jin-Hee;Ahn, Yong-Chan;Kim, Sang-Gi;Kim, Bo-Kyung
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: For the first time, a nationwide survey in the Republic of Korea was conducted to determine the basic parameters for the treatment of esophageal cancer and to offer a solid cooperative system for the Korean Pattern of Care Study database. $\underline{Materials\;and\;Methods}$: During $1998{\sim}1999$, biopsy-confirmed 246 esophageal cancer patients that received radiotherapy were enrolled from 23 different institutions in South Korea. Random sampling was based on power allocation method. Patient parameters and specific information regarding tumor characteristics and treatment methods were collected and registered through the web based PCS system. The data was analyzed by the use of the Chi-squared test. $\underline{Results}$: The median age of the collected patients was 62 years. The male to female ratio was about 91 to 9 with an absolute male predominance. The performance status ranged from ECOG 0 to 1 in 82.5% of the patients. Diagnostic procedures included an esophagogram (228 patients, 92.7%), endoscopy (226 patients, 91.9%), and a chest CT scan (238 patients, 96.7%). Squamous cell carcinoma was diagnosed in 96.3% of the patients; mid-thoracic esophageal cancer was most prevalent (110 patients, 44.7%) and 135 patients presented with clinical stage III disease. Fifty seven patients received radiotherapy alone and 37 patients received surgery with adjuvant postoperative radiotherapy. Half of the patients (123 patients) received chemotherapy together with RT and 70 patients (56.9%) received it as concurrent chemoradiotherapy. The most frequently used chemotherapeutic agent was a combination of cisplatin and 5-FU. Most patients received radiotherapy either with 6 MV (116 patients, 47.2%) or with 10 MV photons (87 patients, 35.4%). Radiotherapy was delivered through a conventional AP-PA field for 206 patients (83.7%) without using a CT plan and the median delivered dose was 3,600 cGy. The median total dose of postoperative radiotherapy was 5,040 cGy while for the non-operative patients the median total dose was 5,970 cGy. Thirty-four patients received intraluminal brachytherapy with high dose rate Iridium-192. Brachytherapy was delivered with a median dose of 300 cGy in each fraction and was typically delivered $3{\sim}4\;times$. The most frequently encountered complication during the radiotherapy treatment was esophagitis in 155 patients (63.0%). $\underline{Conclusion}$: For the evaluation and treatment of esophageal cancer patients at radiation facilities in Korea, this study will provide guidelines and benchmark data for the solid cooperative systems of the Korean PCS. Although some differences were noted between institutions, there was no major difference in the treatment modalities and RT techniques.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method (졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성)

  • Kang, Tae-Hyuk;Min, Byoung-Chul;Ju, Jeh-Beck;Sohn, Tae-Won;Cho, Won-Il
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1078-1086
    • /
    • 1996
  • The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.

  • PDF

Relationship between the Expression of Sodium Iodide Symporter and the Findings of $^{99m}Tc-MIBI$ Scintimammography in the Primary Breast Cancer (원발성 유방암에서 Sodium Iodide Symporter의 발현과 $^{99m}Tc-MIBI$ 유방스캔의 관계)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Chang-Hun;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.325-332
    • /
    • 2002
  • Purpose: Human Na+/I- symporter (hNIS) is known to be expressed in many tissues other than thyroid gland. The breast cancer cells are one of them and the possibility of radioiodine therapy in treatment of the breast cancer may be suggested. We investigated the expression rate of hNIS and the relationship between the expression of hNIS and the finding of 99mTc-MIBI scintimammographv in the breast cancer Materials and Methods: Surgically proved 56 patients with breast cancer were the subjects of this study The expression of hNIS were evaluated by immunohistochemistry and the results were compared to the findings of 99m7c-MIBI scintimammography. Results: Overall expression rate of hNIS was 41.1% in 56 patients. According to the pathologic diagnosis, it was 42.9% in 49 patients with invasive ductal carcinoma and 28.6% in the 7 patients with ductal carcinoma in situ. The expression rate of hNIS in the 41 cases with a focal increased uptake at he breast lesion on 99m7c-MIBI sointimammogram was 31.7%. That in the 15 cases without any abnormal uptake on the scan was significantly higher(65.7%, p<0.05). Conclusion: The expression rate of hNIS in the patients with breast cancer was not so high. The rate was higher in the patients with no increased uptake at the breast lesion on 99m7c-MIBI scintimammography.