• Title/Summary/Keyword: C-scan

Search Result 782, Processing Time 0.029 seconds

Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

  • Hwang, Joon Ho;Sohn, Yong-Hak;Chang, Seong-Sil;Kim, Seung Yeon
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.301-308
    • /
    • 2015
  • Purpose: We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods: Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ${\leq}2,300g$ or were ${\leq}36$ weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). Results: The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels ${\leq}60mg/dL$, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment, after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ${\leq}60mg/dL$), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Conclusion: Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

The solid angle estimation of acetabular coverage of the femoral head using 3D method (입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정)

  • Choi, K.H.;Kim, M.C.;Lim, C.T.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF

Implementation of Parallel Volume Rendering Using the Sequential Shear-Warp Algorithm (순차 Shear-Warp 알고리즘을 이용한 병렬볼륨렌더링의 구현)

  • Kim, Eung-Kon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.6
    • /
    • pp.1620-1632
    • /
    • 1998
  • This paper presents a fast parallel algorithm for volume rendering and its implementation using C language and MPI MasPar Programming Language) on the 4,096 processor MasPar MP-2 machine. This parallel algorithm is a parallelization hased on the Lacroute' s sequential shear - warp algorithm currently acknowledged to be the fastest sequential volume rendering algorithm. This algorithm reduces communication overheads by using the sheared space partition scheme and the load balancing technique using load estimates from the previous iteration, and the number of voxels to be processed by using the run-length encoded volume data structure.Actual performance is 3 to 4 frames/second on the human hrain scan dataset of $128\times128\times128$ voxels. Because of the scalability of this algorithm, performance of ]2-16 frames/sc.'cond is expected on the 16,384 processor MasPar MP-2 machine. It is expected that implementation on more current SIMD or MIMD architectures would provide 3O~60 frames/second on large volumes.

  • PDF

JAXA'S EARTH OBSERVING PROGRAM

  • Shimoda, Haruhisa
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.7-10
    • /
    • 2006
  • Four programs, i.e. TRMM, ADEOS2, ASTER, and ALOS are going on in Japanese Earth Observation programs. TRMM and ASTER are operating well, and TRMM operation will be continued to 2009. ADEOS2 was failed, but AMSR-E on Aqua is operating. ALOS (Advanced Land Observing Satellite) was successfully launched on $24^{th}$ Jan. 2006. ALOS carries three instruments, i.e., PRISM (Panchromatic Remote Sensing Instrument for Stereo Mapping), AVNIR-2 (Advanced Visible and Near Infrared Radiometer), and PALSAR (Phased Array L band Synthetic Aperture Radar). PRISM is a 3 line panchromatic push broom scanner with 2.5m IFOV. AVNIR-2 is a 4 channel multi spectral scanner with 10m IFOV. PALSAR is a full polarimetric active phased array SAR. PALSAR has many observation modes including full polarimetric mode and scan SAR mode. After the unfortunate accident of ADEOS2, JAXA still have plans of Earth observation programs. Next generation satellites will be launched in 2008-2012 timeframe. They are GOSAT (Greenhouse Gas Observation Satellite), GCOM-W and GCOM-C (ADEOS-2 follow on), and GPM (Global Precipitation Mission) core satellite. GOSAT will carry 2 instruments, i.e. a green house gas sensor and a cloud/aerosol imager. The main sensor is a Fourier transform spectrometer (FTS) and covers 0.76 to 15 ${\mu}m$ region with 0.2 to 0.5 $cm^{-1}$ resolution. GPM is a joint project with NASA and will carry two instruments. JAXA will develop DPR (Dual frequency Precipitation Radar) which is a follow on of PR on TRMM. Another project is EarthCare. It is a joint project with ESA and JAXA is going to provide CPR (Cloud Profiling Radar). Discussions on future Earth Observation programs have been started including discussions on ALOS F/O.

  • PDF

Evaluation of Internal Defect of Composite Laminates Using A Novel Hybrid Laser Generation/Air-Coupled Detection Ultrasonic System (레이저 발생 초음파와 공기 정합 수신 탐촉자를 이용한 복합재료 적층판의 내부 박리 결함 평가)

  • Lee, Joon-Hyun;Lee, Seung-Joon;Byun, Joon-Hyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • Ultrasonic C-scan technique is one of very popular techniques being used for detection of flaws in polymer matrix composite(PMC). However, the application of this technique is very limited for evaluation of defects in PMC fabricated by the automated fiber placement process. The purpose of this study is to develop a novel ultrasonic hybrid system based on nondestructive and non-contact ultrasonic techniques for evaluation of delamination in carbon/epoxy and carbon/PPS composite laminates. It was shown that the newly developed ultrasonic hybrid system based on dual air-coupled pitch-catch technique with ultrasonic scattering reflection concept could provide excellent image with higher resolution of delamination in PMC compared with the conventional pitch-catch method. It is expected that this ultrasonic hybrid technique can be applied for on-line inspection of flaws in PMC during the fabrication process.

Fabrication and Evaluation of Hybrid Scaffold by Nano-Micro Precision Deposition System (나노-마이크로 정밀 분사 시스템을 이용한 하이브리드 인공지지체의 제작 및 평가)

  • Ha, Seong-Woo;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.875-880
    • /
    • 2014
  • Recently, three-dimensional scaffolds and nanofibers are being developed for bone tissue regeneration. In this study, we fabricated a hybrid scaffold using a nano-micro precision deposition system. The fabrication process involved the application of the solid freeform fabrication (SFF) technology and electrospinning. The hybrid scaffolds were combined using micro scaffolds and nanofibers. The nanofibers were deposited on each layer of the micro scaffolding using the electrospinning process. The micro scaffolds were fabricated using the SFF technology at a temperature of $100^{\circ}C$, pressure of 650 kPa, and scan velocity of 250 mm/s. Nanofiber fabrication was conducted by means of electrospinning using the flow rate, solution concentration, distance from the tip to the collector (TCD), and voltage. The nanofibers were fabricated using a flow rate of 0.1 ml/min, voltage of 5 kV, TCD of 1 mm, and 10 wt% of solution concentration. MG-63 cells were seeded into the hybrid scaffold for the purpose of its evaluation.

Clinical investigation of bisphosphonate-related osteonecrosis of the jaws in patients with malignant tumors

  • Kim, Sei-Kyoung;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.3
    • /
    • pp.152-159
    • /
    • 2012
  • Objectives: This study evaluated bisphosphonate-related osteonecrosis of the jaws (BRONJ) in patients diagnosed with malignant bone tumors. Demographic findings, laboratory, and radiographic analyses were performed to characterize disease severity and progression. Materials and Methods: Patients who had been diagnosed with BRONJ (2005-2010) at the authors' hospital according to the American Association of Oral and Maxillofacial Surgeons were investigated. Twenty-one patients (12 with multiple myelomas, 7 with breast cancer, and 2 with prostate cancer) who had been treated with bisphosphonates (BPs) for malignant bone tumors were included. Radiographic evaluations with a panorama, computed tomography, whole body bone scan, and laboratory findings were evaluated for erythrocyte sedimentation rate (ESR), c-reactive proteins (CRPs), and c-terminal cross-linked telopeptides (CTXs). Results: The average age of the patients was 64.3 (range 51-80), and they were treated with BPs for an average of $35{\pm}19$ months before BRONJ was diagnosed. Types of BPs were zolendronic acid (81%, intravenous [IV]), pamidronate (4.8%, IV), zoledronic acid+pamidronate (4.8%, IV), alendronate (4.8%, per os [PO]), and ibadronate (4.75%, PO). Extraction (67%) and persistent irritation of dentures (20%) were the most common triggering factors. BRONJ in the mandible was reported in 62% of the cases, in the maxilla 24%, and both 14%. BRONJ occurred more frequently in patients with multiple myelomas (n=12, 57.1%). Most of the patients revealed an advanced BRONJ stage; Stage I (n=2, 9%), Stage II (n=13, 62%), and Stage III (n=6, 29%). Conclusion: The differences of the ESR, CRP, and CTX values between the BRONJ-recurring and non-recurring patients after the treatment were not evident. Later stage BRONJ patients showed lower CTX levels. A drug holiday after the diagnosis of BRONJ did not remarkably influence the surgical outcomes. However, the limited number of patients in the study should be considered.

A Study on Low Velocity Impact and Residual Compressive Strength for Carbon/Epoxy Composite Laminate (탄소섬유/에폭시 복합적층판의 저속 충격 및 잔류 압축강도에 관한 연구)

  • Lee, S.Y.;Park, B.J.;Kim, J.H.;Lee, Y.S.;Jeon, J.C.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.250-255
    • /
    • 2000
  • Damage induced by low velocity impact loading in aircraft composite laminates is the form of failure which is occurred frequently in aircraft. Low velocity impact can be caused either by maintenance accidents with tool drops or by in-flight impacts with debris. As the consequences of impact loading in composite laminates, matrix cracking, delamination and eventually fiber breakage for higher impact energies can be occurred. Even when no visible impact damage is observed, damage can exist inside of composite laminates and the carrying load of the composite laminates is considerably reduced. The reduction of strength and stiffness by impact loading occurs in compressive loading due to laminate buckling in the delaminated areas. The objective of this study is to determine inside damage of composite laminates by impact loading and to determine residual compressive strength and the damage growth mechanisms of impacted composite laminates. For this purpose a series of impact and compression after impact tests are carried out on composite laminates made of carbon fiber reinforced epoxy resin matrix with lay up pattern of $[({\pm}45)(0/90)_2]s$ and $[({\pm}45)(0)_3(90)(0)_3({\pm}45)]$. UT-C scan is used to determine impact damage characteristics and CAI(Compression After Impact) tests are carried out to evaluate quantitatively reduction of compressive strength by impact loading.

  • PDF

Effect of Vibration on Trabecualr Bone of OVX Rats (기계적 자극이 난소 제거한 쥐 해면골에 미치는 영향 분석)

  • Ko C.Y.;Lee T.W.;Woo D.G.;Kim H.S.;Kim C.H.;Lee B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.183-184
    • /
    • 2006
  • Some researchers proposed positive effects of whole body vibration (WBV) on osteoporotic trabecular bones of animals. In the present study, the correlation between the improvement of morphological characteristics and the effect of WBV was investigated and analyzed in OVX rats. The rats were randomly assigned to 5 groups: control, sham, WBV 17Hz, WBV 30Hz and WBV 45Hz. The WBV groups were exercised on a vibration platform (magnitude : $1mm_{peak-peak}$, frequency : 17Hz, 30Hz and 45Hz, 30 minutes/day for 5 days/week). The 4th lumbar on rats was scanned by In-vivo Micro-CT at the week 0(just before WBV) and the week 8(after WBV). Structural parameters of the 4th lumbar, based on two dimensional (2D) scan image data, were investigated and analyzed. The quantitative decrement rate of trabecular bone on WBV groups with 30Hz and 45Hz were lower than control and sham groups. The results showed the positive effect of WBV on osteoporotic bones of OVX rats.

  • PDF

Effect of Vibration on Trabecualr Bone of OVX Rats (기계적 자극이 난소 제거한 쥐 해면골에 미치는 영향 분석)

  • Ko C.Y.;Lee T.W.;Woo D.G.;Kim H.S.;Kim C.H.;Lee B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.649-650
    • /
    • 2006
  • Some researchers proposed positive effects of whole body vibration (WBV) on osteoporotic trabecular bones of animals. In the present study, the correlation between the improvement of morphological characteristics and the effect of WBV was investigated and analyzed in OVX rats. The rats were randomly assigned to 5 groups: control, sham, WBV 17Hz, WBV 30Hz and WBV 45Hz. The WBV groups were exercised on a vibration platform (magnitude $1mm_{peak-peak}$, frequency : 17Hz, 30Hz and 45Hz, 30 minutes/day for 5 days/week). The 4th lumbar on rats was scanned by In-vivo Micro-CT at the week 0(iust before WBV) and the week 8(after WBV). Structural parameters of the 4th lumbar, based on two dimensional (2D) scan image data, were investigated and analyzed. The quantitative decrement rate of trabecular bone on WBV groups with 30Hz and 45Hz were lower than control and sham groups. The results showed the positive effect of WBV on osteoporotic bones of OVX rats.

  • PDF