• Title/Summary/Keyword: C-implant

Search Result 474, Processing Time 0.022 seconds

Influence of crown-to-implant ratio on periimplant marginal bone loss in the posterior region: a five-year retrospective study

  • Lee, Kyung-Jin;Kim, Yong-Gun;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.231-236
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the influence of the crown-to-implant (C/I) ratio on the change in marginal bone level around the implant and to determine the site-related factors influencing the relationship between the C/I ratio and periimplant marginal bone loss. Methods: A total of 259 implants from 175 patients were evaluated at a mean follow-up of five years. Implants were divided into two groups according to their C/I ratios: ${\leq}$ 1, and >1. Site-related factors having an influence on the relationship between C/I ratio and periimplant marginal bone loss were analyzed according to the implant location, implant diameter, implant manufacturer, prosthesis type, and guided bone regeneration (GBR) procedure. Results: It was found that 1) implants with a C/I ratio below 1 exhibited greater periimplant marginal bone loss than implants with a C/I ratio more than 1, 2) site-related factors had an effect on periimplant marginal bone loss, except for the implant system used, 3) the C/I ratio was the factor having more dominant influence on periimplant marginal bone loss, compared with implant diameter, prosthesis type, implant location, and GBR procedure, 4) implants with a C/I ratio below 1 showed greater periimplant marginal bone loss than implants with a C/I ratio greater than 1 in the maxilla, but not in the mandible, 5) and periimplant marginal bone loss was more affected by the implant system than the C/I ratio. Conclusions: Within the limitations of this study, implants with a higher C/I ratio exhibited less marginal bone loss than implants with a lower C/I ratio in the posterior regions. The C/I ratio was a more dominant factor affecting periimplant marginal bone loss in the maxilla than the mandible. Meanwhile, the implant system was a more dominant factor influencing periimplant marginal bone loss than the C/I ratio.

Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems (Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교)

  • Oh, Jun-Ho;Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.529-534
    • /
    • 2008
  • Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.

A Study on the heat generation during implant abutment preparation (임플란트 지대주 삭제시의 발생열에 관한 연구)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Jang, Tae-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

A population-based study of breast implant illness

  • Magno-Padron, David A.;Luo, Jessica;Jessop, Terry C.;Garlick, Jared W.;Manum, Joanna S.;Carter, Gentry C.;Agarwal, Jayant P.;Kwok, Alvin C.
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.353-360
    • /
    • 2021
  • Background Despite evidence supporting the safety of breast implants, some women associate their implants with adverse health effects and have called this syndrome "breast implant illness." We sought to characterize breast implant illness symptoms and to report how implant removal affects their symptoms. Methods An anonymous 20 question survey was administered to the Facebook group: "UTAH Breast Implant Illness" to characterize the symptoms these women attributed to their breast implants. Several questions allowed us to evaluate how implant removal affected women's symptoms. Results Of the 182 respondents, 97% report that implants negatively affect their health and 95% identify these symptoms with breast implant illness. Ninety-six percent of respondents had implants placed for cosmetic reasons and 51% had silicone implants. The most common symptoms associated with breast implant illness are brain fog (95%), fatigue (92%), joint pain (80%), and hair loss (74%). Sixty percent of respondents learned about breast implant illness from family/friends and/or social media platforms (56%), 40% of respondents had their implants removed, and 97% report relief of their symptoms post-removal (23% complete, 74% partial). Following explantation, there was a significant improvement in all but one reported symptom. An association was found between the number of symptoms reported prior to explantation and the number of symptoms resolving following explantation. Conclusions Breast implant illness is a syndrome characterized by fatigue, decreased focus, hair loss, and joint pain after the placement of breast implants. Nearly all patients report improvement of symptoms after implant removal. Significant efforts should be made to better understand breast implant illness and its etiology.

Research for Implant system according to investment condition and Bum out temperature (Implant system의 매몰조건과 소환온도에 대한 조사)

  • Park, Geun-Hyeung
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.115-121
    • /
    • 2001
  • This study was investigated on effect of implant system about investment condition and burn out temperature. Posterior bridges were fabricated by using plastic sleeve and gold sylinder. The results were as follows; In plastic sleeve test and fitting cast copings. the phosphate bonded investment showed better gypsum bonded investment. The pure special liquid showed better margin fitness compared with mixed liquid (special liquid + distilled water). In gold cylinder test. the good burn out temperature of Ceramic PFG and Crown Gold was evaluated $0^{\circ}C$ to $820^{\circ}C$ and was decreased on $780^{\circ}C$ for 30 minutes. $0^{\circ}C$ to $750^{\circ}C$ and was decreased on $650^{\circ}C$ for 30 minutes.

  • PDF

Early implant placement in sites with ridge preservation or spontaneous healing: histologic, profilometric, and CBCT analyses of an exploratory RCT

  • Stefan P. Bienz;Edwin Ruales-Carrera;Wan-Zhen Lee;Christoph H. F. Hammerle;Ronald E. Jung;Daniel S. Thoma
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.108-121
    • /
    • 2024
  • Purpose: The aim of this study was to compare changes in soft and hard tissue and the histologic composition following early implant placement in sites with alveolar ridge preservation or spontaneous healing (SH), as well as implant performance up to 1 year after crown insertion. Methods: Thirty-five patients with either intact buccal bone plates or dehiscence of up to 50% following single-tooth extraction of incisors, canines, or premolars were included in the study. They were randomly assigned to undergo one of three procedures: deproteinized bovine bone mineral with 10% collagen (DBBM-C) covered by a collagen matrix (DBBM-C/CM), DBBM-C alone, or SH. At 8 weeks, implant placement was carried out, and cone-beam computed tomography scans and impressions were obtained for profilometric analysis. Patients were followed up after the final crown insertion and again at 1 year post-procedure. Results: Within the first 8 weeks following tooth extraction, the median height of the buccal soft tissue contour changed by -2.11 mm for the DBBM-C/CM group, -1.62 mm for the DBBM-C group, and -1.93 mm for the SH group. The corresponding height of the buccal mineralized tissue changed by -0.27 mm for the DBBM-C/CM group, -2.73 mm for the DBBM-C group, and -1.48 mm for the SH group. The median contour changes between crown insertion and 1 year were -0.19 mm in the DBBM-C/CM group, -0.09 mm in the DBBM-C group, and -0.29 mm in the SH group. Conclusions: Major vertical and horizontal ridge contour changes occurred, irrespective of the treatment modality, up to 8 weeks following tooth extraction. The DBBM-C/CM preserved more mineralized tissue throughout this period, despite a substantial reduction in the overall contour. All 3 protocols led to stable tissues for up to 1 year.

FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY (IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구)

  • Kim, Byung-Ock;Hong, Kug-Sun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS WITH INTERNAL CONNECTION BETWEEN THE IMPLANT AND THE ABUTMENT (임플란트와 지대주간 내측 연결을 갖는 임플란트 보철의 유한요소 응력분석)

  • Ahn, Jong-Kwan;Kay, Kee-Sung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.356-372
    • /
    • 2004
  • Statement of problom: In the internal connection system the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. Purpose: The purpose of this study was to assess the loading distributing characteristics of 3 implant systems with internal connection under vertical and inclined loading using finite element analysis. Material and method: Three finite element models were designed according to the type of internal connection of ITI(model 1), Friadent(model 2), and Bicon(model 3) respectively. This study simulated loads of 200N in a vertical direction (A), a $15^{\circ}$ inward inclined direction (B), and a $30^{\circ}$ outward inclined direction (C). Result: The following results have been made based on this numeric simulations. 1. The greatest stress showed in the loading condition C of the inclined load with outside point from the centric cusp tip. 2. Without regard to the loading condition, the magnitudes of the stresses taken at the supporting bone, the implant fixture, and the abutment were greater in the order of model 2, model 1, and model 3. 3. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture, and lower stress was taken at the cancellous bone. 4. The stress of the implant fixture was usually widely distributed along the inner surface of the implant fixture contacting the abutment post. 5. The stress distribution pattern of the abutment showed that the great stress was usually concentrated at the neck of the abutment and the abutment post, and the stress was also distributed toward the lower part of the abutment post in case of the loading condition B, C of the inclined load. 6. In case of the loading condition B, C of the inclined load, the maximum von Misess stress at the whole was taken at the implant fixture both in the model 1 and model 2, and at the abutment in the model 3. 7. The stress was inclined to be distributed from abutment post to fixture in case of the internal connection system. Conclusion: The internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, and the abutment according to the abutment connection form had differenence among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the a butment post.