• Title/Summary/Keyword: C-flux

Search Result 1,783, Processing Time 0.027 seconds

Study on Correlation of Critical Heat Flux in Spray Cooling (분무냉각에 있어서 임계열유속 상관식에 관한 연구)

  • Kim, Yeung Chan
    • Journal of ILASS-Korea
    • /
    • v.23 no.3
    • /
    • pp.109-113
    • /
    • 2018
  • The critical heat flux of spray cooling were measured on the test surface of 10 mm diameter made by stainless steel. The experiments were carried out for the droplet-flow-rate of $0.00002{\sim}0.003m^3/(m^2s)$ and liquid subcooling temperature of $40{\sim}75^{\circ}C$. Experimental results showed that the critical heat flux of spray cooling increased remarkably with the increase of droplet-flow-rate. Meanwhile, the effect of liquid subcooling on critical heat flux of spray cooling appeared weakly under the present experimental conditions. In additions, correlation between the dimensionless critical heat flux and Weber number based on droplet-floe-rate was developed for experimental results.

Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate (고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구)

  • Kim, Yeung-Chan
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

Analysis of Flux Observers Using Parameter Sensitivity

  • Nam H.T.;Lee K.J.;Choi J.W.;Kim H.G.;Chun T.W.;Noh E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.418-422
    • /
    • 2001
  • To achieve a high performance in direct vector control of induction motor, it is essential to correct estimation of rotor flux. The accuracy of flux observers for induction machines inherently depends on parameter sensitivity. This paper presents an analysis method for conventional flux observers using Parameter Sensitivity. The Parameter sensitivity is defined as the ratio of the percentage change in the system transfer function to the percentage change of the parameter variation. We define the ratio between real flux and estimated flux as the transfer function, and analyzed a parameter sensitivity of this transfer function by simulation.

  • PDF

Heat Budget in Incheon Coastal Area in 1994 (1994년 인천 연안역의 열수지)

  • 최용규;윤홍주
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.293-297
    • /
    • 1999
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) in Incheon harbor of National Fisheries Research and Development Institute, heat budget in Incheon coastal area was estimated. The temperature differences between the sea surface and near bottom were nearly within 1$^{\circ}C$. This indicate the mixing from the sea surface and the bottom. The net heat flux through the sea surface and the advection through the inner and outer bay was affected uniformly to the water body in Incheon coastal area. The net heat flux was about 110W/$m^2$ in maximum value on May, about -80W/$m^2$ in minimum on January. The net heat flux through the sea surface from the solar radiation was about 2.35$\times$${10}^5$W during the year. This heat flux flew out the bay through the advection by the same flux.

  • PDF

Characteristics Analysis of Short Flux Path Switched Reluctance Motor

  • Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.38-45
    • /
    • 2012
  • A novel kind of switched reluctance motor (SRM) with short flux path is proposed in this paper. Phase excitation in the SRM gives short flux paths, hence reducing the magnetomotive force required to drive the machine, resulting in significant reduction of copper wire and core losses compared to the typical SRM with diametric circulation of magnetic flux. To verify the performance, the characteristics analysis of a double-stator SRM, a 6/5 SRM with C-core structure, and a 4/5 two-phase SRM, which all have short flux paths, and a comparison with conventional SR motors are executed. The comparison demonstrates that the proposed motor offers some advantages in terms of torque and efficiency.

Numerical Analysis of Turbulent Flow and Heat Transfer in a Rectangular Duct with a 180° Bend Degree (직사각단면을 갖는 180°곡관내의 난류 유동및 열전달에 관한 수치해석적 연구)

  • Choi, Y.D.;Moon, C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.325-336
    • /
    • 1994
  • A numerical simulation of velocity and temperature fields and Nusselt number distributions is performed by using the algebraic stress model (ASM) for the velocity profiles and low Reynolds number ${\kappa}-{\varepsilon}$ model and the algebraic heat flux model(AHFM) for turbulent heat transfer in a $180^{\circ}$ bend with a constant wall heat flux. In the low Reynolds number ${\kappa}-{\varepsilon}$ model, turbulent Prandtl number is modified by considering the streamline curvature effect and the non-equilibrium effect between turbulent kinetic energy production and dissipation rate. Every heat flux term presented in the transport equation of turbulent heat flux is reduced to algebraic expressions in a way similar to algebraic stress model. Also. in the wall region, low Reynods number algebraic heat flux model(AHFM) is applied.

  • PDF

Effects of Counterpart Materials on Wear Behavior of Thermally Sprayed Ni-based Self-flux Alloy Coatings (니켈기 자융성 합금 코팅층의 마모거동에 미치는 상대마모재의 영향)

  • Kim, K.T.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.92-97
    • /
    • 2007
  • This study aims at investigating the wear behavior of thermally sprayed Ni-based self-flux alloy coatings against different counterparts. Ni-based self-flux alloy powders were flame-sprayed onto a carbon steel substrate and then heat-treated at temperature of $1000^{\circ}C$. Dry sliding wear tests were performed using the sliding speeds of 0.2 and 0.8 m/s and the applied loads of 5 and 20 N. AISI 52100, $Al_2O_3$, $Si_3N_4$ and $ZrO_2$ balls were used as counterpart materials. Wear behavior of Ni-based self-flux alloy coatings against different counterparts were studied using a scanning electron microscope(SEM) and energy dispersive X-ray spectroscopy (EDX). It was revealed that wear behavior of Ni-based self-flux alloy coatings were much influenced by counterpart materials.

  • PDF

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)

Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate (고온 평판의 분무냉각에 있어서 MHF점에 관한 연구)

  • 김영찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

Continuous Hydrolysis of Cod Skin Gelatin in an Ultrafiltration Reactor (한외여과막 반응기를 이용한 어피젤라틴의 연속적 가수분해)

  • Kim, Se-Kwon;Byun, Hee-Guk;Cheryan,Munir
    • KSBB Journal
    • /
    • v.6 no.3
    • /
    • pp.309-319
    • /
    • 1991
  • A continuous stirred tank membrane reactor(CSTMR ) was developed and optimized for the production of cod skin gelatin hydrolyzates using endo-protease Alcalase. A experimental design methodology was used to optimize the four performance variables: enzyme concentration, substrate concentration, permeate flux and reactor volume. All four variables studied had an effect on substrate conversion, with enzyme and substrate concentrations being predominant. Conversion increased with the increase in enzyme concentration, with the decrease in substrate concentration, at high volumes and low flux. A strong interaction was observed between enzyme and substrate concentrations and smaller interactions between enzyme and flux and substrate and flux. The optimum operating conditions for the CSTMR process for an initial substrate concentration for 10% were $50^{\circ}C$, pH 8, flux 7.3ml/min, residence time 82 min, and Alcalase to substrate ratio 0.02(w/w). A gradual decay in reactor activity during 8 hrs was 2.1% conversion/hr. Enzyme leakage through the 10, 000 MWCO membrane was 16% at $50^{\circ}C$ and 12% at $35^{\circ}C$, 6hrs. However, there was no apparent correlation between enayme leakage and substrate conversion. The Km value for the CSTMR was 20 times higher than the batch reactor. The productivity(expressed as mg product/mg enzyme) of the CSTMR was more than six fold higher than the batch at $50^{\circ}C$. The hydrolyzate was non-bitter.

  • PDF