• Title/Summary/Keyword: C-flux

Search Result 1,782, Processing Time 0.029 seconds

Growth of Superconductor YBa2Cu3O7-x Single Crystal by Flux Method (Flux법에 의한 초전도체 YBa2Cu3O7-x 단결정 육성)

  • 오근호;김호건;명중재
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.1
    • /
    • pp.48-54
    • /
    • 1990
  • YBa2Cu3O7-x(=YBCO) single crystals were grown by flux method and the growing process of crystals was investigated. YBCO and 3BaO-7CuO composition powders were mixed by the ratio of 25 : 75(wt%), and the mixtures were melted at 105$0^{\circ}C$ in a electric furnace with no temperature-gradient. Then the melt was cooled at a rate 2-1$0^{\circ}C$/h in the above furnace. YBCO single crystal plate with average size of $1.5\times$2.0$\times$0.1㎣ were obtained in the cavities between crucible and solidified ingot, and the single crystals were oriented to <001> direction. The ingots of flux parts were analyzed by XRD and EDS for the purpose of presuming the growing process of the crystals. It was assumed that the divorced eutectic reaction, by which YBCO crystals were grown first and then BaCuO2 and CuO crystals, occured in the case of cooling rate faster than 2$^{\circ}C$/h. When the cooling rate was 2$^{\circ}C$/h, it was assumed that quasi-equilibrium eutectic reaction occured, so that YBCO, BaCuO2 and CuO crystals were grown at the same time.

  • PDF

Structural and Thermal Analysis of Disk Brake (디스크 브레이크의 구조 및 열 해석)

  • Cho, Jae-Uug;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.211-215
    • /
    • 2010
  • Continuous contraction and expansion of disk brake can be due to friction and temperature difference at repeated sudden braking. As serious vibration at disk is produced, the braking force will be changed ununiformly and braking system can not be stabilized. Temperature and heat flux at disk brake are investigated by structural and thermal analysis in this study. The maximum equivalent stress and displacement are shown respectively at the ventilated hole and the lower part of disk plate. At thermal analysis of initial state, temperature on disk plate is distributed from $95.9^{\circ}C$ to $100^{\circ}C$. The maximum heat flux of $0.0168W/mm^2$ is shown at the inner friction part between disk plate and pad. At thermal analysis of transient state, temperature on disk plate is distributed from $95^{\circ}C$ to $96.5^{\circ}C$ after 100 second. The maximum heat flux of $0.0024W/mm^2$ is also shown at the inner friction part between disk plate and pad. By comparing with initial state, the temperature on disk plate is more uniformly distributed and heat flux is more decreased by 7 times at transient state.

The Analysis of Current Limiting Performance in a High-$T_c$ Superconductor using Flux-Lock Concepts

  • 임성훈;최효상;김영순;이성룡;한병성
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.229-234
    • /
    • 2002
  • In this paper, we analyzed the fault current performance in a $high-T_{c}$ superconductor(HTS) which was installed on flux-lock reactor with an external magnetic field coil covering the HTS. In this HTS fault current limiter using flux-lock concepts, the initial limiting current level can be controlled by adjusting the inductance of the coils. Furthermore, the current limiting characteristics of $high-T_{c}$ superconducting FCL can be improved by applying the external magnetic field into the $high-T_{c}$ superconductor. This paper discusses current limiting performance according to the inductance of the coil 1 in two cases with ac magnetic field coil or not and suggests the methods to improve the current limiting factor $P_{limit}$, which is defined as the ratio of the limited current $I_{FCL}$ at the current limiting phase to the prospective short -circuit current $I_{PSC}$.TEX> PSC/.

  • PDF

Evaluation of C(t)-integral for inner cracks of steel slab during reheating process (강재의 재가열공정시 내부 균열에 대한 C(t)-적분의 평가)

  • Lee, Kang-Yong;Kim, Jong-Sung;Lee, Hyo-Jin;Park, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.695-703
    • /
    • 1998
  • The crack problem of continuous casting slab due to the thermal stresses during the reheating process is analyzed using FEM. In this study, the C(t)-integral is calculated. As a result, the values of the C(t)-integral decrease by increasing the initial temperature of the slab and decreasing total heat flux. And those decrease by decreasing the heat flux of pre-heating zone and increasing the heat flux of heating zone.

Study on the Performance of the Cascade System Using Alternative Refrigerants (대체냉매를 사용한 이원냉동 시스템의 성능에 관한 연구)

  • 박종훈;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.564-571
    • /
    • 2001
  • The present study investigated the effect of key parameters on the performance of a cascade system using R-22 and R-23 refrigerants. Experimental data for the cascade system have been compared with simulation results using thermodynamic analysis. The cascade system tested at the evaporating temperature of $-80^{\circ}C $ and the condensing temperature of$40^{\circ}C $. The key experimental parameters were the evaporating temperature of the HTC(-35, -30, -25, -20, $-15^{\circ}C $) and mass flux of the HTC(200, 250, 300kg/$m^2$s). As the evaporating temperature and the mass flux of the HTC were increased respectively, the COP and the refrigerating efficiency were increased and then decreased while the volume flow rate per unit refrigeration capacity showed the opposite trend. The maximum COP and refrigerating efficiency were obtained at the evaporating temperature of the HTC of $-25^{\circ}C $ and the mass flux of 250 kg/$m^2$s.

  • PDF

The Precipitation of Second Phases by Annealing Heat Treatment in the $(Bi,Pb)_2$${Sr_2}{Ca_2}{Cu_3}{O_{10}}$ Superconductor System (BSCCO계 초전도체에서 서냉 열처리에 의한 2차상 석출)

  • 이상희;김철진;유재무
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.12
    • /
    • pp.1212-1220
    • /
    • 2000
  • Bi-2223 초전도체계에서 석출물을 flux-pinning center로 이용할 수 있는지 가능성을 타진하기 위하여 $Bi_{1.8}$P $b_{0.4}$S $r_{2}$C $a_{2.2}$C $u_3$ $O_{8}$ 조성을 가진 Bi-2223/Ag 선재를 반응온도, 산소분압, 시간 등을 변화시키면서 열처리를 행하였다. 열처리 후 석출물들은 XRD, SEM, TEM, EDS로 분석하였다. Bi-2223 모상내의 (Ca, Sr)$_2$(Pb,Bi) $O_4$, B $i_{0.5}$ P $b_3$S $r_2$C $a_2$Cu $O_{12+}$$\delta$/ (3221)와 같은 2차상들의 크기와 분포는 2223 입자들의 연결성을 파괴하지 않고 열처리 조건에 의해서 조절할 수 있었다. 서냉 열처리가 된 시편은 임계전류밀도( $J_{c}$)값이 증가하였는데, 이는 2223 입자내 나노미터 크기로 형성된 석출물들이 flux-pinning sites로 작용한 것으로 추정된다.다.

  • PDF

Low temperature sintering and dielectric properties of $Sr_2(Ta_{1-x}Nb_x)_2O_7$ ceramics by the flux method (용융염합성법에 의한 $Sr_2(Ta_{1-x}Nb_x)_2O_7$ 세라믹스의 저온소성과 유전특성)

  • 남효덕
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.158-164
    • /
    • 1995
  • Solid solutions Sr$_{2}$(Ta$_{1-x}$ Nb$_{x}$)$_{2}$O$_{7}$, (x=0.0-1.0), composed of strontium tantalate(Tc=-107.deg. C) and strontium-niobate(Tc=1342.deg. C) were prepared by the conventional mixed oxide method and the flux method(molten salt synthesis method). Phase relation, sintering temperature, grain-orientation and dielectric properties for sintered ceramic samples were investigated with different compositions. Both Curie temperature and dielectric constant at Curie temperature were increased, and sintering behavior and the degree of grain-orientation were improved with the increase of Nb content. The single phase Sr$_{2}$(Ta/sib 1-x/Nb$_{x}$)$_{2}$O$_{7}$ powder was synthesized by using the flux method at lower temperatures, and sintering temperature was also reduced by using the flux method-derived powder than using the mixed oxide-derived powder. Sintering characteristics and dielectric properties of the specimens prepared by the flux method were better than those derived through the conventional mixed oxide method.thod.hod.

  • PDF

Characteristics of GMA Weld Zone on TiO2 Different Component Flux Cored Wire for S500 Grade Steel (TiO2 성분 플럭스충진와이어에 따른 S500강의 GMA 용접부 특성)

  • Yoo, Cheol;Ko, Young-Bong;Park, Kyeung-Chae
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.335-342
    • /
    • 2015
  • Recently, the production of oil and gas at the arctic ocean and offshore has been growing. Accordingly, S500 steel with the high tensile strength and excellent toughness has been used and flux cored wire that can be welded to the S500 has been required. In this study, we carried out observation of microstructures, mechanical properties and CTOD (crack tip openning displacement) in the weld zone that GMA (gas metal arc) welded with different component of $TiO_2$ flux core wire (the main components, rutile or Ti-slag) for S500 steel. Weld zone produced with Ti-slag flux cored wire has formed a enough acicular ferrite and shown excellent impact toughness at $-40^{\circ}C$, tensile strength at room temperature and CTOD at $-20^{\circ}C$. As a result, the developed flux cored wire was suitable for S500 steel.

Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL (삼상 분리형 자속구속형 전류제한기의 동작 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Park, Chung-Ryul;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF

Analysis of Variations in Soil Heat Flux and Air Temperature by Net Radiation at a Mud Flat in Hampyeong Bay (함평만 갯벌에서 순복사에 의한 토양열 플럭스와 기온의 변동 분석)

  • Park, Ho-seon;Kwon, Byung Hyuk;Kim, Il-Kyu;So, Yoon Hwan;Oh, Se Bong;Kang, Dong-hwan
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1101-1110
    • /
    • 2017
  • In this study, we analyze changes in soil heat flux and air temperature in August (summer) and January (winter) according to net radiation, at a mud flat in Hampyeong Bay. Net radiation was observed as $-84.2{\sim}696.2W/m^2$ in August and $-79.4{\sim}352.5W/m^2$ in January. Soil heat flux was observed as $-80.7{\sim}139.5Wm^{-2}$ in August and $-49.09{\sim}137W/m^2$ in January. Air temperature was observed as $24.2{\sim}32.9^{\circ}C$ in August and $-1.5{\sim}11.1^{\circ}C$ in January. The rate of soil heat flux for net radiation ($H_G/R_N$) was 0.17 in August and 0.34 in January. Because the seasonal fluctuation in net radiation was bigger than the soil heat flux, net radiation in August was bigger than in January. We estimated a linear regression function to analyze variations in soil heat flux and air temperature by net radiation. The linear regression function and coefficient of determination for the soil heat flux by net radiation was y=0.19x-7.94, 0.51 in August, and y=0.39x-11.69, 0.81 in January. The time lag of the soil heat flux by net radiation was estimated to be within ten minutes in August 2012 and January 2013. The time lag of air temperature by net radiation was estimated at 160 minutes in August, and 190 minutes in January.