• 제목/요약/키워드: C-arm fluoroscopy

검색결과 39건 처리시간 0.03초

An Alternative Approach to Needle Placement in Cervicothoracic Epidural Injections

  • Park, Seung-Yong;Leem, Jung-Gil;Jung, Sung-Hwan;Kim, Young-Ki;Koh, Won-Uk
    • The Korean Journal of Pain
    • /
    • 제25권3호
    • /
    • pp.183-187
    • /
    • 2012
  • The use of fluoroscopy guidance together with the loss of resistance technique during epidural injections has been advocated lately; moreover, epidural injections in the absence of fluoroscopic guidance have a high rate of inaccurate needle-tip placement during the injections. However, the approach to the lower cervical and upper thoracic epidural space may be challenging due to its obscure lateral fluoroscopic views from overlying normal tissue structures. In this case, we report an alternative oblique C-arm fluoroscopy guided view approach to supplement the standard anterior-posterior and lateral fluoroscopic views to facilitate successful needle placement and precise anatomical localization of the epidural space.

C-arm 방사선 투영법을 이용한 식도 점막 하 이물 제거 (Removal of Esophageal Submucosal Foreign Body Under C-arm Fluoroscopic Guidance)

  • 김희진;김효상;차원재;성명훈;하정훈
    • 대한기관식도과학회지
    • /
    • 제19권1호
    • /
    • pp.15-18
    • /
    • 2013
  • Esophageal foreign body is common condition for visit emergency room, and most of them were successfully removed with endoscopy. However, in case of esophageal foreign body impaction, it can be difficult to localize the foreign body. We report a 29-year old man with esophageal foreign body impaction. We successfully localized and removed the esophageal submucosal foreign body using rigid endoscopy under C-arm guidance, avoiding more invasive procedure. The patient was followed up without any complication.

  • PDF

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

The radiation safety education and the pain physicians' efforts to reduce radiation exposure

  • Kim, Tae Hee;Hong, Seung Wan;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제30권2호
    • /
    • pp.104-115
    • /
    • 2017
  • Background: C-arm fluoroscopy equipment is important for interventional pain management and can cause radiation injury to physicians and patients. We compared radiation safety education and efforts to reduce the radiation exposure of pain specialists. Methods: A survey of 49 pain specialists was conducted anonymously in 2016. The questionnaire had 16 questions. That questionnaire was about radiation safety knowledge and efforts to reduce exposure. We investigated the correlation between radiation safety education and efforts of radiation protection. We compared the results from 2016 and a published survey from 2011. Results: According to the 2016 survey, all respondents used C-arm fluoroscopy in pain interventions. Nineteen respondents (39%) had received radiation safety education. Physicians had insufficient knowledge about radiation safety. When the radiation safety education group and the non-education group are compared, there was no significant difference in efforts to reduce radiation exposure and radiation safety knowledge. When the 2011 and 2016 surveys were compared, the use of low dose mode (P = 0.000) and pulsed mode had increased significantly (P = 0.001). The number checking for damage to radiation protective garments (P = 0.000) and use of the dosimeter had also increased significantly (P = 0.009). But there was no significant difference in other efforts to reduce radiation exposure. Conclusions: Pain physicians seem to lack knowledge of radiation safety and the number of physicians receiving radiation safety education is low. According to this study, education does not lead to practice. Therefore, pain physicians should receive regular radiation safety education and the education should be mandatory.

Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures

  • Jung, Cheol Hee;Ryu, Jae Sung;Baek, Seung Woo;Oh, Ji Hye;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제26권1호
    • /
    • pp.51-56
    • /
    • 2013
  • Background: The C-arm fluoroscope is an essential tool for the intervention of pain. The aim of this study was to investigate the radiation exposure experienced by the hand and chest of pain physicians during C-arm fluoroscopy-guided procedures. Methods: This is a prospective study about radiation exposure to physicians during transforaminal epidural steroid injection (TFESI) and medial branch block (MBB). Four pain physicians were involved in this study. Data about effective dose (ED) at each physician's right hand and left side of the chest, exposure time, radiation absorbed dose (RAD), and the distance from the center of the X-ray field to the physician during X-ray scanning were collected. Results: Three hundred and fifteen cases were included for this study. Demographic data showed no significant differences among the physicians in the TFESIs and MBBs. In the TFESI group, there was a significant difference between the ED at the hand and chest in all the physicians. In physician A, B and C, the ED at the chest was more than the ED at the hand. The distance from the center of the X-ray field to physician A was more than that of the other physicians, and for the exposure time, the ED and RAD in physician A was less than that of the other physicians. In the MBB group, there was no difference in the ED at the hand and chest, except for physician D. The distance from the center of the X-ray field to physician A was more than that of the other physicians and the exposure time in physician A was less than that of the other physicians. Conclusions: In conclusion, the distance from the radiation source, position of the hand, experience and technique can correlate with the radiation dose.

The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room

  • Ryu, Jae Sung;Baek, Seung Woo;Jung, Cheol Hee;Cho, Suk Ju;Jung, Eu Gene;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제26권2호
    • /
    • pp.142-147
    • /
    • 2013
  • Background: Medical doctors who perform C-arm fluoroscopy-guided procedures are exposed to X-ray radiation. Therefore, radiation-protective shields are recommended to protect these doctors from radiation. For the past several years, these protective shields have sometimes been used without regular inspection. The aim of this study was to investigate the degree of damage to radiation-protective shields in the operating room. Methods: This study investigated 98 radiation-protective shields in the operation rooms of Konkuk University Medical Center and Jeju National University Hospital. We examined whether these shields were damaged or not with the unaided eye and by fluoroscopy. Results: There were seventy-one aprons and twenty-seven thyroid protectors in the two university hospitals. Fourteen aprons (19.7%) were damaged, whereas no thyroid protectors (0%) were. Of the twenty-six aprons, which have been used since 2005, eleven (42.3%) were damaged. Of the ten aprons, which have been used since 2008, none (0%) was damaged. Of the twenty-three aprons that have been used since 2009, two (8.7%) of them were damaged. Of the eight aprons used since 2010, one (12.3%) was damaged. Of the four aprons used since 2011, none (0%) of them were damaged. The most common site of damage to the radiation-protective shields was at the waist of the aprons (51%). Conclusions: As a result, aprons that have been used for a long period of time can have a higher risk of damage. Radiation-protective shields should be inspected regularly and exchanged for new products for the safety of medical workers.

수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로) (Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study))

  • 최성현;조황우;동경래;정운관;최은진;송하진
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

Intraoperative Vertebral Artery Angiography to Guide C1-2 Transarticular Screw Fixation in a Patient with Athetoid Cerebral Palsy

  • Chung, Jong-Chul;Jung, Sung-Sam;Park, Ki-Seok;Ha, Ho-Gyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.177-181
    • /
    • 2012
  • We present a case of an athetoid cerebral palsy with quadriparesis caused by kyphotic deformity of the cervical spine, severe spinal stenosis at the cervicomedullary junction, and atlantoaxial instability. The patient improved after the first surgery, which included a C1 total laminectomy and C-arm guided righ side unilateral C1-2 transarticular screw fixation. C1-2 fixation was not performed on the other side because of an aberrant and dominant vertebral artery (VA). Eight months after the first operation, the patient required revision surgery for persistent neck pain and screw malposition. We used intraoperative VA angiography with simultaneous fluoroscopy for precise image guidance during bilateral C1-2 transarticular screw fixation. Intraoperative VA angiography allowed the accurate insertion of screws, and can therefore be used to avoid VA injury during C1-2 transarticular screw fixation in comorbid patients with atlantoaxial deformities.

요부교감신경차단으로 척수경색 환자의 하지통증 치료 -증례보고- (Lumbar Sympathetic Block for Spinal Cord Infarction Patient -A case report-)

  • 김동희;박상욱;김형지
    • The Korean Journal of Pain
    • /
    • 제19권2호
    • /
    • pp.237-240
    • /
    • 2006
  • This report describes a case of spinal cord infarction after acupuncture. The patient was treated with lumbar sympathetic block with using C-arm fluoroscopy. A 66-year-old patient with chronic low back pain and radiating pain in the lower limb was treated with acupuncture and he suddenly had a loss of motor and sensory of both lower extremities. His clinical presentaion and neuroimaging studies were consistent with spinal cord infarction. He was treated with steroid megatherapy and he showed improved in motor function, but there was no pain relief despite the phamacological treatments that were combined with caudal blockade. He visited to our hospital and had lumbar sympathetic blockade performed. The pain was relieved without any related complication after 1 month (VAS $9/10{\rightarrow}2/10$), and he has been content with the results of treatment.