• Title/Summary/Keyword: C-C Coupling

Search Result 1,225, Processing Time 0.021 seconds

Load-Settlement Behavior of Rock-socketed Drilled Shafts by Bi-directional Pile Load Test (양방향 말뚝선단재하시험에 의한 암반근입 현장타설말뚝의 하중-침하거동 분석)

  • Seol, Hoon-Il;Jeong, Sang-Seom;Han, Keun-Taek;Kim, Jae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.61-70
    • /
    • 2008
  • Load settlement behaviors and load transfer characteristics of rock-socketed pile subjected bi-directional load at pile tip were investigated using bi-directional pile load tests (BD PLT) performed on ten large-diameter drilled shafts at four sites. Based on test results, additional pile-toe displacement ($w_{bs}$) by coupled soil resistance was analyzed, and thus equivalent top loaded load-settlement curve of pile subjected bi-directional load was proposed by taking into account the coupled soil resistance. Through comparisons with field case studies, it is found that for test piles there exists effect of coupled soil resistance, which is represented by wbs, and thus an equivalent curve obtained by existing uncoupled methods can overestimate bearing capacity of piles by BD PLT. On the other hand, the analysis by the proposed method with soil coupling effect has a considerably larger settlement when compared with the results by uncoupled load transfer method and estimates reasonable load-settlement behaviors of test piles. In case of pile socketed in high strength rocks, however, effects of coupled soil resistance can be neglected.

Experimental and analytical study of squat walls with alternative detailing

  • Leonardo M. Massone;Cristhofer N. Letelier;Cristobal F. Soto;Felipe A. Yanez;Fabian R. Rojas
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.497-507
    • /
    • 2024
  • In squat reinforced concrete walls, the displacement capacity for lateral deformation is low and the ability to resist the axial load can quickly be lost, generating collapse. This work consists of testing two squat reinforced concrete walls. One of the specimens is built with conventional detailing of reinforced concrete walls, while the second specimen is built applying an alternative design, including stirrups along the diagonal of the wall to improve its ductility. This solution differs from the detailing of beams or coupling elements that suggest building elements equivalent to columns located diagonally in the element. The dimensions of both specimens correspond to a wall with a low aspect ratio (1:1), where the height and length of the specimen are 1.4 m, with a thickness of 120 mm. The alternative wall included stirrups placed diagonally covering approximately 25% of the diagonal strut of the wall with alternative detailing. The walls were tested under a constant axial load of 0.1f'cAg and a cyclic lateral displacement was applied in the upper part of the wall. The results indicate that the lateral strength is almost identical between both specimens. On the other hand, the lateral displacement capacity increased by 25% with the alternative detailing, but it was also able to maintain the 3 complete hysteretic cycles up to a drift of 2.5%, reaching longitudinal reinforcement fracture, while the base specimen only reached the first cycle of 2% with rapid degradation due to failure of the diagonal compression strut. The alternative design also allows 46% more energy dissipation than the conventional design. A model was used to capture the global response, correctly representing the observed behavior. A parametric study with the model, varying the reinforcement amount and aspect ratio, was performed, indicating that the effectiveness of the alternative detailing can double de drift capacity for the case with a low aspect ratio (1.1) and a large longitudinal steel amount (1% in the web, 5% in the boundary), which decreases with lower amounts of longitudinal reinforcement and with the increment of aspect ratio, indicating that the alternative detailing approach is reasonable for walls with an aspect ratio up to 2, especially if the amount of longitudinal reinforcement is high.

Synthesis and Characterization of Thermally Cross-linkable Hole Transporting Material Based on Poly(p-phenylenevinylene) Derivative (열경화가 가능한 poly(p-phenylenevinylene)계 정공전달 물질의 합성 및 특성)

  • Choi, Jiyoung;Lee, Bong;Kim, Joo Hyun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.3
    • /
    • pp.299-303
    • /
    • 2008
  • A thermally cross-linkable polymer, poly[(2,5-dimethoxy-1,4-phenylenevinylene)-alt-(1,4-phenylenevinylene)] (Cross-PPV), was synthesized by the Heck coupling reaction. In order for the polymer to be cross-linkable, 20 mol% excess divinylbenzene was added. The chemical structure of Cross-PPV and thermally crosslinked Cross-PPV were confirmed by FT-IR spectroscopy. From the FT-IR, UV-Vis, and PL spectral data, thermally crosslinked Cross-PPV was insoluble in common organic solvents. The HOMO and LUMO energy level of thermally cross-linked Cross-PPV were estimated -5.11 and -2.56 eV, respectively, which were determined by the cyclic voltammetry and UV-Vis spectroscopy. From the energy level data, one can easily notice that thermally crosslinked Cross-PPV can be used for hole injection layer effectively. Bilayer structured device (ITO/crosslinked Cross-PPV/PM-PPV/Al) was fabricated using poly(1,4-phenylenevinylene-(4-dicyanomethylene-4H-pyran)-2,6-vinylene-1,4-phenylenevinylene-2,5-bis(dodecyloxy)-1,4-phenylenevinylene (PM-PPV) as the emitting layer, which have HOMO and LUMO energy levels of -5.44 eV and -3.48 eV, respectively. The bilayered device had much enhanced the maximum efficiency (0.024 cd/A) and luminescence ($45cd/m^2$) than those of a single layer device (ITO/PM-PPV/Al, 0.003 cd/A, $3cd/m^2$). The enhanced performance originated from that fact that cross-linked Cross-PPV facilitatse the hole injection to the emissive layer and the injected hole and electron from ITO and Al are recombined in emitting layer (PM-PPV) effectively.

Optical properties of $ZnIn_2Se$ and $ZnIn_2Se_4$:Co single crystals ($ZnIn_2Se_4$$ZnIn_2Se_4$:Co 단결정의 광학적 특성)

  • 최성휴;방태환;박복남
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.129-135
    • /
    • 1997
  • Undoped and Co-doped $ZnIn_2Se_4$ single crystals crystallized in the tetragonal space group 142m, with lattice constants a=5.748 $\AA$ and c=11.475 $\AA$, and a=5.567 $\AA$ and c=11.401 $\AA$. The optical absorption measured near the fundamental band edge showed that the optical energy band structure of these compounds had an indirect band gap, the direct and the indirect energy gaps of these compounds decreased as temperature changed from 10 to 300 K. The temperature coefficients of the direct energy gaps were found to be $\alpha=3.71\times10^{-4}$eV/K and $\beta$=519 K for $\alpha=3.71\times10^{-4}$eV/K and $\beta$=421K for $ZnIn_2Se_4$: Co. The temperature coefficients of the indirect energy gaps were also found to be $\alpha=2.31\times10^{-4}$ eV/K and $\beta$=285 K for $ZnIn_2Se_4$, and $\alpha=3.71\times10^{-4}$eV/K and $\beta$=609 K for $ZnIn_2Se_4$:Co, respectively. Six impurity optical absorption peaks due to cobalt are observed in $ZnIn_2Se_4$:Co single crystal. These impurity optical absorption peaks can be attibuted to the electronic transitions between the split energy levels of$CO^{2+}$ ions located at Td symmetry site of $ZnIn_2Se_4$ host lattice. The 1st order spin-orbit coupling constant ($\lambda$), Racah parameter (B), and crystal field parameter (Dq) ARE GIVEN AS -$243\textrm{cm}^{-1}, 587\textrm{cm}^{-1}, \;and\;327\textrm{cm}^{-1}$, respectively.

  • PDF

Studies on Salient Metabolites of Plant Tissues (I) -Nitrogen Metabolism and Proline Accumulation in Halophytes- (식물조직계(植物組織系)의 유효성분(有效成分)에 관(關)한 연구(硏究) [1] -내염성(耐鹽性) 식물(植物)의 Proline축적(蓄積) 및 질소대사(窒素代謝)-)

  • Cho, I.H.
    • Applied Biological Chemistry
    • /
    • v.20 no.2
    • /
    • pp.221-227
    • /
    • 1977
  • Contents of proline and chloride in halophytes were $80-1700\;{\mu}g/gfw$ and 0.13-0.45 mM/gfw respectively. The content of proline was inversely proportional to that of chloride. Rhizomes of Phargmites communis Trin, a halophyte, were grown in non-saline medium and then taken to saline treatment for one or two weeks. Growth of P. communis was inhibited when salinized with 0.25M NaCl. Total nitrogen decreased and alcohol soluble nitrogen and proline increased when growth was retarded. The quantity of Fraction 1 protein decreased at 0.25M NaCl treatment. The accumulation of proline at high concentration in P. communis suggested that it might play a role in osmotic adjustment.

  • PDF