• 제목/요약/키워드: C mode

검색결과 3,072건 처리시간 0.037초

자동차 내부의 김서림 감지 및 제거를 위한 최적의 조건 (Optimal Conditions for Mist Sensing and Removal in Automobile)

  • 유도현
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.763-769
    • /
    • 2012
  • For mist sensing, temperature-humidity sensor is attached on six positions of front glass and rearview mirror in automobile. Bottom-left side of front glass is the best position where mist is sensing. For mist removal, air conditioner is turned on intensity 1, 3 and is set the temperature at 17[$^{\circ}C$], 25[$^{\circ}C$]. And heater is turned on intensity 1, 3 and is set the temperature at 25[$^{\circ}C$], 32[$^{\circ}C$]. The best condition which mist is removed is temperature at 17[$^{\circ}C$] and intensity 3 of air conditioner mode. At this condition, total average value of humidity output voltage difference is 0.561[V]. Also, air conditioner mode is effective than heater mode for mist sensing and removal.

한글인식 후처리용 단어사전의 기억구조 (A Word Dictionary Structure for the Postprocessing of Hangul Recognition)

  • 김상운
    • 한국통신학회논문지
    • /
    • 제19권9호
    • /
    • pp.1702-1709
    • /
    • 1994
  • 한글인식 후처리에서 문맥정보의 저장구조는 인식율 및 인식속도를 결정짓는 중요한 요소이다. 단어사전의 형태로 문맥정보를 표현하기 위해서는 트라이(trie)를 주로 이용하지만, 기억공간 이용효율이 저조하다는 단점이 있다. 따라서 이 논문에서는 트라이의 장점을 유지하면서 공간효율을 향상시키는 기억구조를 제안한다. 한글은 조합문자이기 때문에 자모나 문자별로 기억시킬 수 있다. 그런데 자모단위로 기억시키면(P-모드) 검색시간은 빠르지만 공간효율이 나쁘고, 또한 문자단위로 기억시키면(C-모드) 공간효율은 좋지만 검색시간이 길어진다. 따라서 노드이용율과 분산율로 최적레벨을 선정한 다음, 입력단어의 시작자모부터 최적레벨까지는 자모 단위의 트라이로 기억시키고, 그 이상은 문자단위의 순차연결구조로 저장시켰다. (H-모드). 6가지 단어집합에 대하여 실험한 결과, H-모드에서의 검색시간은 P-모드만큼 빠르면서, 공간효율은 C-모드와 같게 되어 그 효용성을 확인할 수 있었다.

  • PDF

초폭굉모드 램가속기의 성능에 대한 이론적 연구 (Analytical Study on Performance of Superdetonative Mode Ram Accelerator)

  • 성근민;정인석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.77-80
    • /
    • 2013
  • An analytical study on performance of superdetonative mode ram accelerator was conducted for understanding the S225 experimental result of ISL. It would be noticeable that ISL S225 experimental result could be analytically simulated with the assumptions of inlet shockwave, equilibrium combustion chemistry, temperature dependent specific heat, and C-J oblique detonation in superdetonative operation mode. As result, the S225 experiment could be affected by heat of aluminum. Also, this study showed that the improper assumption, like isentropic assumption on shockwave, or constant specific heat on combustion, might cause misunderstanding about experimental result.

  • PDF

Electro-Optic Characteristics of a Nonchiral Smectic C Liquid Crystal Display Mode in a Twisted Geometry

  • Jeong, Cherl-Hyun;Yu, Chang-Jae;Choi, Yoon-Seuk;Jung, Min-Sik;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.567-570
    • /
    • 2003
  • We demonstrated a fast liquid crystal (LC) display mode based on a nonchiral smectic C LC in a twisted geometry. In this twisted nonchiral smectic C (TNSC) LC mode, the analog gray scales and wide viewing properties are achieved. The continuous gray scales in the TNSC LC mode are obtained in a dielectrically driving scheme as those in the nematic mode.

  • PDF

Aggregation Prodesses of Hydrophobically Modified Polythylene Oxide

  • 백기욱;김범성;김응렬;손대원
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권6호
    • /
    • pp.623-627
    • /
    • 2000
  • Aggregation of hydrophobically end-capped poly(ethylene oxide)s: HEURs, denoted as $C_8$$EO_{380}$$C_8$, $C_12$$CO_{600}$$C_{12}$, and $C_{18}$$EO_{860}$$C_{18}$,are described using static fluorescence, dynamic light scattering, and atomic force microscope (AFM) techniques. The CAC (critical aggregation concentration) was determined by com-paring two fluorescent peaks which were influenced by the polarity of the probe dye molecules, pyrene. The aggregation occurs in concentrations higher than 10 g/L of $C_8$$EO_{380}$$C_8$ and the CAC decreases by increasing the side chain length. The dynamic light scattering experiment shows fast mode and slow mode decays, and both are diffusive. The fast mode does not depend on the concentration, but the slow mode shows concentration dependence influenced by the formation of an aggregated structure. The hydrophobic end groups effect more dominantly than the main chains for the formation of HEUR micelles. By increasing the concentration, the HEUR micelles change their structure from spheres to rodlike micelles, and finally make fused structures, which were visualized with atomic force microscopy.

$CO_2$ 용접의 천이이행 조건에서 스패터 발생과 파형인자와의 관계 (Relationship between Spatter Generation and Waveform Factors in Transitional Condition of $CO_2$ Welding)

  • 강봉용;이창한;김희진;장희석
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 1998
  • $CO_2$ gas shielded arc welding has been characterized with its harsh arc compared to Ar-based shielding gases and with its high level of spattere specially in welding current range of 250~300 amperes. In this range of welding current, the metal transfer mode showed to be changed from short circuit to globular with the increase of welding voltage resulting in so-called the transitional mode in which both modes of transfer appeared together. To characterize the transitional mode, the short circuit events were divided into two groups, i.e. normal short circuit (N.S.C) which has short circuit time $(t_s)$ over 2msec and instantaneous short circuit (I.S.C) of $t_s$$\leq$2msec. The experimental results showed that the number of N.S.C decreased almost linearly with the increase of welding voltage and appeared to be not related with spatter generation rate. However I.S.C became to be pronounced in the transitional condition and its number reached the maximum value at around 29.0 volts. Considering the relation with the spatter generation rate, it was found that the number of I.S.C had a very strong correlation with the spatter generation rate of the transitional condition. It was further demonstrated that spatter generation rate decreased quite linearly with the decrease of I.S.C frequency. It implies that I.S.C is the most important waveform factor controlling the spatter generation of the transitional mode, i.e. in the middle range of welding current. Based on these results, It was discussed that in the transitional mode the basic concept of waveform control for suppressing spatter generation would be different from the one applied for typical short circuit transfer mode of low welding current.

  • PDF

Two-mode Fiber with a Reduced Mode Overlap for Uncoupled Mode-division Multiplexing in C+L Band

  • Hong, Seongjin;Choi, Kyoungyeon;Lee, Yong Soo;Oh, Kyunghwan
    • Current Optics and Photonics
    • /
    • 제2권3호
    • /
    • pp.233-240
    • /
    • 2018
  • We proposed a two-mode fiber (TMF) design that can effectively reduce the mode overlap between $LP_{01}$ and $LP_{11}$ modes by using a W-shaped index profile core structure, which is a primary concern in uncoupled mode division multiplexing (MDM). TMF has a three-layered core structure; central circular core, inner cladding, and outer ring core. We confirmed that in an optimal structure the $LP_{01}$ mode was highly confined to the central core while the $LP_{11}$ mode was guided along the outer ring core to result in a minimum overlap integral. We used a full-vectorial finite element method to estimate effective index, differential group delay (DGD), confinement loss, chromatic dispersion, and mode overlap controlling the parameters of the W-shaped structure. The optimized W-profile fiber provided optical characteristics within the ITU-T recommended standards over the entire C+L band.

D대학 수변전설비의 고장모드 영향 분석 (Failure Modes and Effects Analysis for Electric Power Installations of D University)

  • 박영호;김두현
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.7-15
    • /
    • 2016
  • The purpose of this paper is to carry out Failure Modes and Effects Analysis (FMEA) and use criticality in order to determine risk priority number of the components of electric power installations in Engineering college building of D university. In risk priority number, GROUP A had 7 failure modes; more specifically, Transfomer had 4 modes, Filter(C)(1 mode), LA(1 mode), and CB(MCCB)(1 mode), and thus 4 components had failure modes. In terms of criticality, high-grade group a total of 16 failure modes, and 7 components-LA(1 mode), CB(MCCB)(1 mode), MOF(2 modes), PT(1 mode), Transformer(7 modes), Cable(3 modes), and Filter(C)(1 mode)-had failure modes. Comparison of risk priority number and criticality was made. The components which had high risk priority number and high criticality were Transformer, Filter(C), LA, and CB(MCCB). The components which had high criticality were MOF and cable. In particular, Transformer(RPN: 4 modes, Criticality: 7 modes) was chosen as an intensive management component.

저전력 전류모드 CMOS 기준전압 발생 회로 (A Low-Power Current-Mode CMOS Voltage Reference Circuit)

  • 권덕기;오원석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.1077-1080
    • /
    • 1998
  • In this paper, a simple low-power current-mode CMOS wotage reference circuit is proposed. The reference circuit of enhancement-mode MOS transistors and resistors. Temperature compensation is made by adding a current component proportional to a thermal voltage to a current component proportional to a threshold voltage. The designed circuit has been simulated using a $0.65\mu\textrm{m}$ n-well CMOS process parameters. The simulation results show that the reference circuit has a temperature coefficient less than $7.8ppm/^{\circ}C$ and a power-supply(VDD) coefficient less than 0.079%/V for a temperature range from $-30^{\circ}C$ to $130^{\circ}C$ and a VDD range from 4.0V to 12V. The power consumption is 105㎼ for VDD=5V and $T=30^{\circ}C.$ The proposed reference circuit can be designed to generate a wide range of reference voltages owing to its current-mode operation.

  • PDF

Fe-Aluminide합금의 미세조직과 기계적 특성에 관한 연구 (A Study on the Microstructure and Mechanical properties of Fe Aluminide alloys)

  • 조종춘;이도인;이성재;최병학;김학민
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.115-125
    • /
    • 1992
  • Mechanical properties and microstructure were investigated on vacuum induction melted $Fe_3A1$base alloys of $DO_3$ structure. Specal emphasis were put on the effect of alloy chemistry, grain size and process(rolling, directional solidification) on mechanical properties of Fe-22.5-39at.%Al at elevated temperature between room temperature and $800^{\circ}C$. grain size of as-cast alloys is refined by rolling from 1mm to $80\mum$. Tensile strength of Fe-24.lat.%AI was about 404MPa at the critical ordering temperature, and the fracture strain of the alloy was 1-2% at room temperature. An inverse temperature dependence of the strength is noticed as-cast $Fe_3A1$. The presence of Cr and Zr do not affect the room temperature ductility and high temperature strength. Fracture strain of directionally solidified(DS) $Fe_3A1$ is about 1%at room temperature, but is about 60%at. $T_C$(550^{\circ}C)$. Tensile strength of DS alloy is lower than that of as-cast alloy at $530^{\circ}C$ and $430^{\circ}C$. Failure mode at room temperature varies from transgranular fracture to intergranular fracture with the addition of Al. the failure mode also varies from mixed(transgranular+ intergranular) mode between room temperature and $500^{\circ}C$ to intergranular mode above $550^{\circ}C$

  • PDF