• 제목/요약/키워드: Bypass ratio

검색결과 161건 처리시간 0.019초

Fallot 4징증의 근치수술후 예후에 영향을 미치는 요소 (Factors influencing the prognosis after total correction of tetralogy of Fallot)

  • 민용일;오봉석;이동준
    • Journal of Chest Surgery
    • /
    • 제20권1호
    • /
    • pp.71-80
    • /
    • 1987
  • Twenty six patients were operated a total correction of tetralogy of Fallot between Jan., 1984 and July, 1985 at the Dept. of thoracic and cardiovascular surgery, Chonnam University Medical School, and a comparison between the survived group [n = 18] and the dead group [n = B was performed to detect factors influencing laboratory data, cineangiographic findings, operative findings and methods, and pump time. Following results were obtained, 1. There was no significant difference between two groups in the preoperative P.O2 and hematocrit level. 2. The size of the interventricular defect was not related to the operative mortality. 3. There was a significant difference in mortality rate between combined type of stenosis of pulmonary artery, valve and infundibulum and other types of right ventricular outflow tract stenosis. 4. There was a significant difference in mortality rate between the transannular patch reconstruction and other types of operative procedure. 5. There was no significant difference between two groups in total bypass time and aortic time. 6. There was no significant difference between two groups in left ventricular end diastolic volume and right ventricular end diastolic volume. 7. The operative mortality was related to the ratio of the diameter of the pulmonary valve annulus or each pulmonary artery to the ascending or descending aorta in cineangiographic findings, but there was no statistical significance of which probably is due to the lack of the total number of patients.

  • PDF

동맥관개존증의 임상적 고찰 (A Clinical Study of Patent Ductus Arteriosus)

  • 이형렬
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.528-535
    • /
    • 1987
  • A clinical study was performed on 164 cases of PDA experienced at the Dept. of Thoracic and Cardiovascular Surgery of Pusan National University Hospital during 6 years from Jan. 1981 to Dec. 1986. It was shown that the PDA was a female-dominant heart disease [male to female ratio, 1:2.8] and two most common symptoms were frequent URI [45.6%] and exertional dyspnea [36.7%]. Continuous machinery murmurs were detected in 143 cases [87.2%], increased pulmonary vascularities [89.0%] and cardiomegalies [63.4%] by chest X-ray. The signs of LVH [43.9%], RVH [3.7%] and BVH [4.9%] were noted on the EKG. Cardiac catheterizations were performed on 67 out of 164 patients and the mean systolic pulmonary artery pressure was 48mmHg [range: 18-131mmHg] and the mean Qp/Qs was 3.1 [range:1.2-8.5] and Rp/Rs below 0.25 was 83.6%. Associated cardiac anomalies were VSD [7.9%], ASD [3.0%], pulmonary valvular stenosis [2.4%] and left persistent SVC [2.4%]. Operative methods were as follows; ligations [145; 88.4%] and divisions [6;3.7%] were performed through the left posterolateral thoracotomies without mortality and the remained cases [13;8.0%] were managed under the cardiopulmonary bypass because of the associated cardiac anomalies. Atelectasis [4.9%] and pneumonia [4.3%] were most frequent postoperative complications and the overall mortality rate was 2.4% [4 out of 164 cases].

  • PDF

이차공형 심방중격결손증의 임상적 고찰 (Clinical Analysis of Secundum Atrial Septal Defect)

  • 정황규
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.520-527
    • /
    • 1987
  • Clinical analysis was performed of 89 secundum type atrial septal defect patients operated on during the period from July, 15th, 1981 to March, 1987 in the Thoracic and Cardiovascular Surgery Department of Pusan National University Hospital. Secundum type ASD was 2`I.0% among all of congenital heart diseases operated in the same period. The age distribution of patients ranged from 3 to 41 years and sex ratio, male to female was 1.23 to 1.0. Common symptoms were exertional dyspnea 64.0%, frequent upper respiratory infection 43.8%, cyanosis 10.1% and fatigue 7.9%. The mean value of cardiac catheterization data of the group of ASD combined with another cardiovascular anomalies was compared with that of only ASD group. The amount of shunt showed not statistically significant difference between two groups [P>0.05] but pulmonary arterial pressure and pulmonary vascular resistance of combined group was significantly higher than that of only ASD group [P<0.02, P<0.01]. The difference of mean hemodynamic data between the age group below 20 years and above 21 years was not statistically significant [P>0.05]. All cases were operated under cardiopulmonary bypass. Among these 51 were closed directly and 38 were applied Dacron patch. Two most common associated cardiac anomalies were pulmonary stenosis [8 cases, 9.0%] and VSD [8 cases, 9.0%]. The most frequent postoperative complication was wound infection, One patient died of low cardiac output on 10th postoperative day and the overall operative mortality was 1.1%

  • PDF

사행유로를 갖는 고분자연료전지내부에서 가스확산층을 통과하는 반응가스 우회유동에 대한 연구 (A Study on the Bypass Flow Penetrating Through a Gas Diffusion Layer in a PEM Fuel Cell with Serpentine Flow Channels)

  • 조중원;안은진;이승보;윤영기;이원용
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.288-297
    • /
    • 2009
  • A serpentine channel geometry often used in a fuel cell has a strong pressure gradient between adjacent channels in specific regions. The pressure gradient helps some amount of reactant gas penetrate through a gas diffusion layer(GDL). As a result, the overall serpentine flow structure is slightly different from the intention of a designer. The purpose of this paper is to examine the effect of serpentine flow structure on current density distribution. By using a commercial code, STAR-CD, a numerical simulation is performed to analyze the fuel cell with high aspect ratio of active area. To increase the accuracy of the numerical simulation, GDL permeabilities are measured with various compressive forces. Three-dimensional flow field and current density distribution are calculated. For the verification of the numerical simulation results, water condensation process in the cathode channel is observed through a transparent bipolar plate. The result of this study shows that the region of relatively low current density corresponds that of dropwise condensation in cathode channels.

Exploiting Correlation Characteristics to Detect Covert digital communication

  • Huang, Shuhua;Liu, Weiwei;Liu, Guangjie;Dai, Yuewei;Tian, Wen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권8호
    • /
    • pp.3550-3566
    • /
    • 2020
  • As a widely used way to exfiltrate information, wireless covert channel (WCC) brings a serious threat to communication security, which enables the wireless communication process to bypass the authorized access control mechanism to disclose information. Unlike the covert channel on the network layer, wireless covert channels on the physical layer (WCC-P) is a new covert communication mode to implement and improve covert wireless communication. Existing WCC-P scheme modulates the secret message bits into the Gaussian noise, which is also called covert digital communication system based on the joint normal distribution (CJND). Finding the existence of this type of covert channel remains a challenging work due to its high undetectability. In this paper, we exploit the square autocorrelation coefficient (SAC) characteristic of the CJND signal to distinguish the covert communication from legitimate communication. We study the sharp increase of the SAC value when the offset is equal to the symbol length, which is caused by embedding secret information. Then, the SAC value of the measured sample is compared with the threshold value to determine whether the measured sample is CJND sample. When the signal-to-noise ratio reaches 20db, the detection accuracy can reach more than 90%.

R245fa 냉매를 이용한 배열회수 히트펌프 시스템 성능에 관한 실험적 연구 (Experimental Study on the Performance of Heat Recovery Heat Pump System using R245fa Refrigerant)

  • 김현택;김용찬;차동안;권오경
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.408-413
    • /
    • 2016
  • The objective of this study is to investigate the performance of a heat recovery heat pump dryer using a R245fa refrigerant experimentally. In this study, the main components of the heat pump dryer were an evaporator, a compressor, a condenser, and an expansion valve. As a result, when the amount of refrigerant varied from 15 kg to 16 kg, the hot air outlet temperature in the condenser and the heat transfer rate were almost kept constant. Therefore, the amount of refrigerant at 16 kg was considered to be a suitable amount in the heat pump. As the air inlet velocity varied from 0.5 m/s to 1.5 m/s, the highest temperature in the condenser could be obtained when the air inlet velocity was 0.5 m/s. The heat transfer rate, system (COP), and hot air outlet temperature were 5.6 kW, 3.4, and $102.5^{\circ}C$, respectively, when the bypass ratio and water temperature were 0% and $60^{\circ}C$.

가스확산층을 통과하는 반응가스 우회유동이 고분자 연로전지의 성능에 미치는 영향 (The Effect of a Bypass Flow Penetrating through a Gas Diffusion Layer on Performance of a PEM Fuel Cell)

  • 조중원;안은진;이승보;이원용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.147-151
    • /
    • 2007
  • A serpentine channel geometry often used in a polymer electrolyte membrane fuel cell has a strong pressure gradient between adjacent channels in specific regions. The pressure gradient helps some amount of reactant gas penetrate through a gas diffusion layer(GDL). As a result, the overall serpentine flow structure is slightly different from intention of a designer. The purpose of this paper is to examine the effect of serpentine flow structure on current density distribution. By using a commercial code, STAR-CD, a numerical simulation is performed to analyze the fuel cell with relatively high aspect ratio active area. To increase the accuracy of the numerical simulation, GDL permeabilities are measured with various compression conditions. Three-dimensional flow field and current density distribution are calculated. For the verification of the numerical simulation results, water condensation process in the cathode channel is observed through a transparent bipolar plate. The result of this study shows that the region of relatively low current density corresponds to that of dropwise condensation in cathode channels.

  • PDF

Senning 및 Mustard 수술후 장기 성적 (Late Results of the Senning and Mustard Operations for TGA in Children)

  • 서경필
    • Journal of Chest Surgery
    • /
    • 제22권1호
    • /
    • pp.32-41
    • /
    • 1989
  • We scrutinized the 64 cases of TGA and Taussig-Bing anomaly who underwent Senning and Mustard operations from Jan. 1981 to May 1988. The ratio of male to female was 45; 19, and the age at operation varied from 2 months to 18 years [mean 18.9*32.9 months]. The in-hospital mortality was in 24 cases [37.5%] and the major causes were myocardial failure and congestive heart failure associated with arrhythmias. The risk factors for hospital mortality were complex TGA, prolonged bypass time and high postoperative CVP. In addition, mortality increased during the first year the procedure was used. Late mortality occurred in 6 cases and the major causes was congestive heart failure, and there was not any significant risk factor noted in late mortality. Early arrhythmia developed in 37.5%, all of which were transient and self limited and 7 cases of early mortality were related to the arrhythmias. Late arrhythmias developed in 8 cases, but 7 cases were transient. One case died with junctional tachycardia. Of significance the one case that died late by arrhythmia had a similar junctional tachycardia in the early postoperative period. The survival rate in all cases disregarding initial in-hospital mortality 1YSR 89.8% and 5YSR 84.3%, but because of short duration of follow up this is not significant. We concluded that early hospital mortality could be decreased by operating at an earlier age and by adjusting the appropriate operation method.

  • PDF

만성 수축성 심낭염의 임상적 고찰 (A Study of Chronic Constrictive Pericarditis)

  • 김현경
    • Journal of Chest Surgery
    • /
    • 제24권10호
    • /
    • pp.973-978
    • /
    • 1991
  • From January, 1982, to December, 1990, 15 patients underwent pericardiectomy for chronic constrictive pericarditis on Department Of Thoracic and Cardiovascular Surgery, School of Medicine, Pusan National University. There were 9 male and 6 female patients [male to female ratio was 1.5: 1] ranging from 15 years to 63 years old [mean age 35.0]. All patients underwent pericardiectomy through a median sternotomy, partial cardiopulmonary bypass was performed on two patients. There were 3 postoperative death [20%]. Six cases [40%] were tuberculous origin 5 cases [34%] were Idiopathic [nonspecific chronic inflammatory change was considered to idiopathic], 2 cases [13%] were malignant origin, 2 cases [13Yo] were pyogenic origin. Dyspnea on exertion was evident in all patients and abdominal distention, general weakness, palpitation, peripheral edema were found. Eleven patients showed low voltage of QRS wave, 7 patients showed diffuse ST-T wave change, 2 patients showed atrial fibrillation on EKG. There were 6 patient showed pericardial thickening, 5 patients showed evidence of restriction, 5 patients showed pericardial effusion, 4 patients showed low cardiac output on preoperative echocardiogram. Hemodynamic response to pericardiectomy were observed; preoperative CVP 26.8 cmH2O declined to 15.0 cmH2O. Preoperative NYHA Functional class showed class II - 1, class III - 10, class IV - 4, postoperative NYHA functional class showed class I - 7, class II - 4, class Ill - l.

  • PDF

일회용 각종 송혈관의 관류압차에 대한 비교실험 (An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas)

  • 김요한;김형묵
    • Journal of Chest Surgery
    • /
    • 제19권1호
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF