• 제목/요약/키워드: Bypass control

검색결과 259건 처리시간 0.02초

Performance optimization control of supersonic variable cycle engines

  • Tagashira, Takeshi;Sugiyama, Nanahisa
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.779-783
    • /
    • 2004
  • First this paper introduces an advanced FADEC (Full Authority Digital Electric Control) for current and future jet engines.It is designed to realize not only stable thrust control, but also performance improvement, reliability enhancement, service life extension, etc. It can be built by using current micro-processor with high computational power and there exists no difficulties but reliability problem of the micro- processor. Next, the simulation results of SFC minimization control are shown. The target engine is a supersonic, low-bypass ratio, 2-spool, combined cycle turbofan, designated as HYPR90T, which consists of a turbo engine for under Mach 3 flight and a ram engine for over Mach 3 flight. he results can then be used for performance optimization of the engine, which plays important role in the advanced FADEC.

  • PDF

운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 (Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions)

  • 백승문;손창효;허정호;최인수;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1021-1026
    • /
    • 2014
  • 본 논문에서는 hot-gas를 이용한 다양한 바이패스 제어 방식 중에서 증발기 흡입부 방식에 대해 각각의 성능에 영향을 미치는 외기온도, 출수온도, 과열 및 과냉도 등에 대해서 알아보았다. 그 주요 결과를 요약하면 다음과 같다. 우선, 증발기 흡입부로 hot-gas를 바이패스 하였을 경우에 냉동장치의 성능은 외기온도, 출수온도, 과열 및 과냉도 등에 영향을 받는 것을 알 수 있었다. 따라서 이러한 변수에 대한 최적화를 통해 본 냉동장치의 기초 설계 자료를 제공할 수 있다. 그리고 증발기 흡입부 hot-gas 바이패스 방식의 운전특성을 고찰하여 본 논문에서 제안하는 냉동장치에 대한 적용 가능성을 확인할 수 있었다.

Change of Blood Magnesium Level in Diabetes Patients Undergoing Off-pump Coronary Artery Bypass Grafting

  • Seo, Si-Young;Moon, Seong-Min;Hyun, Kyung-Yae;Kim, Chong-Rak;Choi, Seok-Cheol
    • 대한의생명과학회지
    • /
    • 제15권3호
    • /
    • pp.207-215
    • /
    • 2009
  • We carried out this study to investigate differences of physiological variables between patients with (DM group) and without type II diabetes mellitus (Non-DM group) undergoing off-pump coronary artery bypass grafting (OPCABG). Postoperative $Mg^{++}$ and $Ca^{++}$ levels were lower, whereas $Na^+$ level was higher in DM group than those in Non-DM group. ICU (intensive care unit) stay time in DM group was longer than that of Non-DM group. Postoperative platelet counts tended to decrease, whereas C-reactive protein (CRP) and cardiac troponin-I (cTNI) levels tended to increase in DM group compared with Non-DM group. Postoperative albumin level was lower, while blood urea nitrogen (BUN) and creatinine levels were greater in DM group than those in Non-DM group. DM group had higher incidence of post-operative arrhythmias than Non-DM group. These results reveal that type II DM patients undergoing OPCAB may have higher incidences of postoperative hypomagnesemia, hypocalcemia and arrhythmias, and increases of CRP, cTNI, BUN, and creatinine levels than in Non-DM patients undergoing OPCAB. The perioperative check and control (supplement) of $Mg^{++}$ levels should be considered in cardiovascular surgery combined with DM.

  • PDF

Effects of Ulinastatin on Postoperative Blood Loss and Hemostasis in Atrioventricular Valve Surgery with Cardiopulmonary Bypass

  • Park, Jae Bum;Kim, Seong Hyop;Lee, Song Am;Chung, Jin Woo;Kim, Jun Seok;Chee, Hyun Keun
    • Journal of Chest Surgery
    • /
    • 제46권3호
    • /
    • pp.185-191
    • /
    • 2013
  • Background: Cardiopulmonary bypass (CPB) induces variable systemic inflammatory reactions associated with major organ dysfunction via polymorphonuclear neutrophils (PMNs). Ulinastatin, a urinary trypsin inhibitor, inhibits PMN activity and reduces systemic inflammatory responses. The aim of this study is to evaluate the effect of ulinastatin on postoperative blood loss and laboratory changes in patients undergoing open heart surgery. Materials and Methods: Between January 2008 and February 2009, 110 patients who underwent atrioventricular valve surgery through right thoracotomy were divided into two groups. Patients received either 5,000 U/kg ulinastatin (ulinastatin group, n=41) or the equivalent volume of normal saline (control group, n=69) before aortic cross clamping. The primary end points were early coagulation profile changes, postoperative blood loss, transfusion requirements, and duration of intubation and intensive care unit stay. Results: There were no statistically significant differences between the two groups in early coagulation profile, other perioperative laboratory data, and postoperative blood loss with transfusion requirements. Conclusion: Administration of ulinastatin during operation did not improve the early coagulation profile, postoperative blood loss, or transfusion requirements of patients undergoing open heart surgery. In addition, no significant effect of ulinastatin was observed in major organs dysfunction, systemic inflammatory reactions, or other postoperative profiles.

박리성 대동맥류(DeBakey Type III)의 외과적 치험 -2예보고- (dissecting aortic aneurysm (DeBakey Type III) -Report of two cases-)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • 제19권3호
    • /
    • pp.443-448
    • /
    • 1986
  • Aortic dissection is a serious disease that mortality does not approach to zero despite of medical and surgical improvement. Recently two cases of aortic dissection were treated with good results by the two other methods. Case 1 [57-Y-0-Male]; Chief complaint was chest pain radiating to the back. Preoperatively he was controlled by Minipress, dichlotride, & sodium nitroprusside. Aortography showed DeBakey Type III aortic dissection extending from just below the Lt. subclavian artery to the proximal portion of the origin of the renal artery. Through the midline long incision Flow reversal & Thrombo-exclusion method was used, and bypass course was proximal anastomosis at the ascending aorta - through the Rt. thoracic cavity - midportion of the diaphragm - posterior to the liver, stomach, & pancreas - distal anastomosis at the abdominal aorta proximal to its bifurcation. Bypass graft was preclotted 20 mm Dacron Woven Graft, and the aortic arch between the Lt. subclavian artery & Lt. common carotid artery was divided and meticulously sutured. Control aortogram which was done at 4th postoperative month revealed obstruction of the false lumen by thrombosis, and complications were not noticed. Case 2 [53-Y-0-Male]; Chief complaint was chest pain radiating to the abdomen. DeBakey Type III aortic dissection which was similar to the case 1 was detected by the aortography, and involvement of the Lt. subclavian & common carotid arteries was suspicious. Through the Lt. posterolateral thoracotomy the Ringed Intraluminal Sutureless Graft, No. 22 mm, was inserted from just below the Lt. common carotid artery to the midportion of the descending thoracic aorta under total circulation arrest using a F-F bypass, and the Lt. subclavian artery was ligated. Postoperatively hospital course was uneventful with antihypertensive drugs, and any specific complications were not noticed.

  • PDF

입원 기간 중 관상동맥 우회술 환자를 위한 심장재활 교육의 효과 (Effect of Cardiac Rehabilitation Education for Coronary Artery Bypass Grafting Patients during Their Hospitalization)

  • 최명애;김금순;이명선;최스미;이정숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제10권1호
    • /
    • pp.69-79
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of cardiac rehabilitation education for CABG patients on anxiety & depression, self-esteem, general health status, health related quality of life, body mass index, serum lipid concentration (high density lipoprotein, low density lipoprotein, total cholesterol), heart rate and blood pressure. The subjects of the study consisted of 36 patients who underwent CABG at A hospital in Seoul, from January 1, 2006 to June 30, 2007. The experimental group (20 patients) received the individual education during the hospitalization. The control group (16 patients) received routine discharge education by ward nurses. Psychological variables, general health status and health related quality of life (QOL) after cardiac rehabilitation education were determined by self-reported questionnaire at 1st week, 3rd week and 6th week after the discharge. Physiological variables were measured in out patient visiting at 4th week after discharge. Score of anxiety & depression and health related QOL in the experimental group showed a significant decrease at 1st week, 3rd week and 6th week after the discharge compared with the control group. Score of self-esteem, general health status and physiological variables in the experimental group showed no significant difference from the control group.

  • PDF

바이패스용 3-Way 밸브를 장착한 온수 난방시스템의 압력 및 유량 특성 평가 (Performance Test of Pressure and Flow Rate in a Hot-Water Heating System with 3-Way Valves for Flow Bypass)

  • 허전;이석종;성재용;이명호;윤재동
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.269-274
    • /
    • 2007
  • A 3-way valve has been applied to a distributor in a hot-water heating system and the performance of the system was evaluated in view of the variations of pressure drop and flow rate. The 3-way valve has been designed to bypass overplus hot-water when a control valve is closed. Note that the flow goes through heating pipeline in normal operation. In the present study, the measured pressure drops in each part of the flow paths show that the contribution to the total pressure drop is in the order of the supply header with control valves, piping system of each room and return header of the distributor, even though the amount of it is different according to the flow paths. As a result of performance test by sequential closing of the control valves, the variations of pressure drop and flow rate in the distributor with 3-way valves is much lower than those with previous 2-way valves, which prevent noises induced by pressure fluctuations.

DBMS WAS 우회접속의 쿼리정보 역추적 연구 (A Study on Traceback by WAS Bypass Access Query Information of DataBase)

  • 백종일;박대우
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권12호
    • /
    • pp.181-190
    • /
    • 2009
  • 초고속 인터넷의 웹 서비스를 사용하여 WAS를 통한 DBMS 접근이 늘어나고 있다. 불특정 다수에 의한 DBMS에 대한 3-Tier와 우회접속에 대한 접근 및 권한제어를 위해서는 DB보안 기술의 적용이 필요하다. WAS를 통해 DBMS에 우회접속을 하면 DBMS는 우회접속 사용자의 IP정보를 저장하지 못하고, 직전 시스템에 접속한 사용자인 WAS의 정보를 저장하게 된다. 본 논문에서는 WAS를 통해 DBMS에 우회접속하는 쿼리정보를 역추적하여 보안감사기록과 포렌식자료를 연구한다. 통신 경로에서 MetaDB를 구축해 웹을 통해 login한 사용자에 대한 세션과 쿼리 정보를 저장하고, DBMS에도 로그 되는 쿼리 정보를 저장해서 time stamp쿼리를 비교 매핑 하여 실제 사용자를 식별한다. 보안 신뢰성의 향상 방법으로, log을 받아 Pattern분석 후에 Rule을 만들어 적용하고, Module을 개발해 정보의 수집 및 압축을 통해 데이터 저장소에 보관한다. 보관된 정보는 지능형 DB보안 클라이언트를 이용한 분석과 정책 기반 관리 모듈의 통제를 통해 역추적의 오탐률을 최소화할 수 있게 한다.

Effect of Feeding Bypass Protein with Urea Treated Grass on the Performance of Red Kandhari Calves

  • Wankhede, S.M.;Kalbande, V.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권7호
    • /
    • pp.970-973
    • /
    • 2001
  • An experiment was carried out to assess the effect of feeding concentrate mixtures varying in bypass protein levels with urea-treated or untreated grass on the performance of twelve Red Kandhari calves (14 months of age and 78.15 kg body weight) for a period of 75 days. Dry grass was treated with 4 percent urea solution and ensiled for 30 days. The CP ($N{\times}6.25$) content in urea treated grass increased from 3.96 to 8.89 percent. Two iso-caloric and iso-nitrogenous concentrate mixtures (CM-I and CM-II) varying in RDP to UDP ratio viz., 65:35 and 55.45 were prepared. The calves in control group ($T_1$) were fed concentrate mixture-I with ad libitum untreated dry grass and those in experimental group ($T_2$) were fed concentrate mixture-II with ad libitum urea treated dry grass. The dry matter consumption in group $T_2$ was significantly (p<0.01) higher as compared to group $T_1$. The total DMI in $T_1$ and $T_2$ was 146.92 and 166.95 kg respectively, whereas the DMI per day and per 100 kg body weight was 1.94 and 2.22 and 1.90 and 2.35 kg, respectively. The average total gain in body weight (kg) and average daily gain (g) of calves in $T_2$ was significantly (p<0.01) higher as compared to those in $T_1$ the values being 28.66, 18.33 and 382.16, 244.44, respectively. Feed efficiency in terms of kg DM per kg gain in body weight was significantly (p<0.01) lower in group $T_1$ than in $T_2$. The cost of feed per kg gain in body weight for $T_2$ and $T_1$ group was Rs. 21.14, 28.22, respectively. The digestibility coefficients of DM, CP, EE, CF, NFE, NDF and ADF were 59.60, 57.50, 53.00, 65.04, 45.82, 48.48, 52.48 and 55.73 for $T_1$ group. The coressponding values were 68.78, 67.80, 59.83, 71.41, 49.93, 53.37 and 57.81, respectively for $T_2$ group. The digestibility coefficients for all the proximate principles in $T_2$ were significantly (p<0.01) higher as compared to $T_1$. However, NDF and ADF digestibilities were not significantly different. Nutritive value determined in terms of DCP and TDN for The experimental ration was significantly (p<0.01) higher than control ration, the values being 7.32 and 47.34 and 9.39 and 52.40% respectively. The blood urea nitrogen levels at 0, 3 and 6 h interval after feeding were significantly (p<0.01) lower in calves fed experiment ration as compared to control. The overall results indicated that in Red Kandhari calves an optimum growth can be economically achieved by feeding 4 percent urea treated dry and mature grass as basal roughage supplemented with a concentrate mixture containing 20 percent CP, 70% TDN and 45% UDP/bypass protein.

Comparison Study on Power Output Characteristics of Power Management Methods for a Hybrid-electric UAV with Solar Cell/Fuel Cell/Battery

  • Lee, Bohwa;Kwon, Sejin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권4호
    • /
    • pp.631-640
    • /
    • 2016
  • A dual-mode power management for a hybrid-electric UAV with a cruise power of 200W is proposed and empirically verified. The subject vehicle is a low-speed long-endurance UAV powered by a solar cell, a fuel cell, and a battery pack, which operate in the same voltage bounds. These power sources of different operational characteristics can be managed in two different methods: passive management and active management. This study proposes a new power management system named PMS2, which employs a bypass circuit to control the individual power sources. The PMS2 normally operates in active mode, and the bypass circuit converts the system into passive mode when necessary. The output characteristics of the hybrid system with the PMS2 are investigated under simulated failures in the power sources and the conversion of the power management methods. The investigation also provides quantitative comparisons of efficiencies of the system under the two distinct power management modes. In the case of the solar cell, the efficiency difference between the active and the passive management is shown to be 0.34% when the SOC of the battery is between 25-65%. However, if the SOC is out of this given range, i.e. when the SOC is at 90%, using active management displays an improved efficiency of 6.9%. In the case of the fuel cell, the efficiency of 55% is shown for both active and passive managements, indicating negligible differences.