Pressure Measurement in Double Inlet Pulse Tube Refrigerator (이중 입구형 맥동관 냉동기에서의 압력 파형 측정)

  • 정제헌;남관우;정상권;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.390-396
    • /
    • 2004
  • A double-inlet pulse tube refrigerator was fabricated as a U-shape with $\Phi$19.0 mm${\times}$125 mm regenerator packed by #200 stainless steel mesh and $\Phi$12.7 mm${\times}$125 mm pulse tube. A pressure sensor was installed at the inlet of the regenerator and a differential pressure sensor was installed across the bypass. Amplitude of the pulsating pressure was independent of the opening of the orifice and the bypass valves. Helium flow through the orifice and the bypass was calculated based on the measured pressure. Energy loss through the orifice and the bypass was evaluated with the measured pressure and the calculated helium flow rate. The energy loss, which is equivalent to the refrigeration capacity at the cold end of the ideal pulse tube refrigerator, was mainly generated through the orifice. It was proportional to the opening of the orifice valve, but the real refrigerator displayed the best performance at the optimized opening of the orifice valve. This optimized performance of the tested pulse tube refrigerator can be explained by additional refrigeration losses. As an example, the shuttle heat transfer loss of the pulse tube was calculated from the measured experimental data.

Experimental Study on Characteristics of Two-Phase Flow through a Bypass Orifice Expansion Device

  • Choi, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2001
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which was a short tube haying a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them. and it would enhance the seasonal energy efficiency ratio of an inverter heat pump system, Based on experimental data, a semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model`s prediction was within $\pm$5%.

  • PDF

Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device (바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구)

  • Choi, J.M.;Kim, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

The effects of cold therapy on pain related to chest tube removal in patients with coronary artery bypass graft surgery (냉요법 적용이 관상동맥 우회술 환자의 흉관 제거시 통증에 미치는 효과)

  • Jeon, Mi-Kyeong;Kim, Keum-Soon
    • Journal of Korean Critical Care Nursing
    • /
    • v.1 no.1
    • /
    • pp.33-45
    • /
    • 2008
  • Purpose: Patients who underwent a coronary artery bypass graft surgery(CABG) experienced the unpleasant emotions and discomfort when their chest tube was removed. The purpose of this study was to evaluate the effects of cold therapy on pain related to chest tube removal(CTR) in CABG patients. Methods: Fifty adult patients undergoing CABG were recruited in a prospective, double blinded study. Subjects were divided into the experimental group and the control group considering their sex and age. The pretest data were obtained 20 minutes before CTR. Patients in the experimental group, received cold therapy for 10 minutes before CTR. Pain sense and intensity were determined immediately after CTR and at 10 minutes after CTR. Results: The total score of pain sense immediately after CTR of the experimental group was significantly lower than that of the control group(t=-3.703, p=.003). And scores of pain intensity immediately after CTR in the experimental group were significantly lower than that of the control group(t=-3.073, p=.001). But, there was no significant difference in the score of pain intensity 10 minutes after CTR between the experimental and the control group(t=1.759, p=.085). Conclusion: The cold therapy would be recommended as an effective and nonpharmacologic nursing intervention for relieving pain in patients undergoing CTR.

  • PDF

Change of End-tidal PCS During Cardiopulmonary Bypass (체외순환시 호기말 이산화탄소압의 변화)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1399-1403
    • /
    • 1992
  • The evaluation of the effectivess of ongoing cardiopulmonary resucitation efforts is dependent on the commonly used methods, such as the presence of femoral or carotid artery pulsations, arterial blood gas determinations, peripheral arterial pressure and intracardiac pressure monitoring. But recent studies suggest that end-tidal carbon dioxide tension serves as a non-invasive measurement of pulmonary blood flow and therefore cardiac output under constant ventilation. A prospective clinical study was done to determine whether end-tidal carbon dioxide monitoring in open heart surgery under cardiopulmonary bypass could be used as a prognostic indicator of bypass weaning. We monitored end-tidal PCO2 values continuously during cardiopulmonary bypass in 30 patients. "Ohmeda 5210 CO-2 monitor" under infrared absorption method were incorperated into the ventilator circuit by means of a side point adaptor between endotracheal tube and ventilator tubing. 18 patients[Group I ] were res-ucitated from partial bypass followed by aorta cross clamp off and 12 patients[Group II ] from aorta cross clamp off followed by partial bypass. But there was no difference between two groups[p>0.05]. The value of end-tidal carbon dioxide tension during ventricular fibrillation or nearly arrest state was 6.6$\pm$2.9 mmHg, and at the time of spontaneous beating was 19.3$\pm$5.6 mmHg[Mean$\pm$Standard deviation], In conclusion end-tidal carbon dioxide tension monitoring provides clinically useful, continous, noninvasive and supplementary prognostic indicator during cardiopulmonary bypass weaning procedures.rocedures.

  • PDF

Tracheal Reconstruction with High Frequency Jet Ventilation in Patients of Tracheal Stenosis (기관 협착 환자에서 고빈도 제트 환기법응 이용한 기관 성형술)

  • 김정택
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.1021-1026
    • /
    • 1990
  • The patients with tracheal stenosis have become more increasing in recent due to the increased use of tracheostomy and assisted ventilation Anesthetic management during tracheal reconstruction is a concern to the anesthetist and the surgeon, who must share the airway as a operation field and at the same time provide good gas exchange. Multiple technique such as the tube ventilation system or C \ulcornerP bypass method have been recommended to achieve this goals. However, these methods have disadvantages of poor surgical exposure and hemorrhagic complication from using C \ulcornerP bypass The technique for HFJV was first described for bronchoscopy, and it involves positive-pressure breathing with high flow[40 \ulcorner60L/min] of oxygen This flow is directed to a semirigid catheter inserted in the endotracheal tube and the tracheal reconstruction can be done without interruption. From Dec. 1986 to July 1990 we have experienced 6 patients of tracheal stenosis necessitating circumferential resection and end to end anastomosis; 5 patients with tracheal stenosis following cuffed tracheostomy or intubation, a patient with tracheal stenosis due to invasive thyroid cancer. The specific advantages during tracheal reconstruction are unobstructed field during surgical reconstruction and good gas exchange through the procedure.

  • PDF

Takayasu`s Arteritis; A Case Report (Takayasu 동맥염;치험 1례)

  • 유웅철
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.245-248
    • /
    • 1993
  • Recently we experienced a case of Takayasu`s arteritis involving the major aortic branches. A 30 year-old female patient admitted with the complaints of dizziness, visual disturbance, headache and tingling sensation of upper extremities. Aortogram revealed nearly complete obstruction of the origin site of both common carotid arteries and right vertebral artery, and irregular luminal narrowing of the origin site of innominate artery and left subclavian artery, but opacification of right subclavian artery and left vertebral artery. Successful surgical treatment was accomplished with a bypass from the ascending aorta to the left common carotid artery using a tube graft. The left subclavian artery and right axillary artery were revascularized distal to the stenosis with tube grafts that extended from the aortic graft. Postoperative complications were atelectasis, lymph leakage and left phrenic nerve palsy. She discharged uneventually at postoperative 22 days and most of symptoms were relieved.

  • PDF

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

Development of a Screw Type Super-Charger for Part Load Control of Passenger Car (승용차의 부분부하제어를 위한 스크류형 과급기 개발)

  • Bea, Jae-Il;Bae, Sin-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1427-1434
    • /
    • 2003
  • Turbo- or Super-charging has been used to boost engine power for Gasoline- and Diesel Engine since beginning of 20th century. So far turbo-charger has enjoyed a high reputation in the charging field for its technical advantages such as no demand of operation power from engine and an excellent charging effect in a static operation at mid- and high engine speed. A mechanically driven super-charger, however, is now popular due to the high engine power at quick change of the driving mode - high engine torque even at low engine speed. Since super-charger needs operation power from engine, it is difficult to improve its relatively higher fuel consumption than that of turbo-charger. This negative point is still an obstacle to the wide use of supercharger. Super-charger using screw-type compressor will fulfill the purpose to reduce fuel consumption by minimizing operation power owing to no charge at idling or part load driving condition. This study aims to develop power control concept to achieve the minimization of operation power. A screw type super-charger was modified in design partially and installed with an internal bypass valve and a bypass tube to control charging pressure at part load. The various control concepts show a possibility to reduce operation power of super-charger.

The Study on the Control Performance of a Screw Type Super-charger for Automotive Use (자동차용 스크류형 과급기의 제어성능에 관한 연구)

  • 배재일;배신철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.21-29
    • /
    • 2003
  • Boosting of engine power by using Turbo- or Super-charger is a solution to comply with $CO_2$-regulation in Europe. Turbo-charger is now playing a major role in the field of charging system thank to its technical advantages such as no demand of operation power from engine. A mechanically driven Super-charger, however, is now popular due to quick speed response to change of the driving mode-high engine torque even at low engine speed. Since Super-charger needs operation power from engine, it is difficult to improve its relatively higher fuel consumption than that of Turbo-charger. This negative point is still an obstacle to the wide use of Super-charger. This study aims to develop power control concept to achieve the minimization of operation power when it is not necessary to charge at idling or part load driving condition. A screw type Super-charger was modified in design partially and adapted an internal bypass valve and a bypass tube to control charging pressure at part load. The various control concepts show a possibility to reduce operation power of Super-charger and result in improvement of fuel consumption.