• Title/Summary/Keyword: Butterworth

Search Result 124, Processing Time 0.022 seconds

The Forecasting a Maximum Barbell Weight of Snatch Technique in Weightlifting (역도 인상동작 성공 시 최대 바벨무게 예측)

  • Hah, Chong-Ku;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.143-152
    • /
    • 2005
  • The purpose of this study was to predict the failure or success of the Snatch-lifting trial as a consequence of the stand-up phase simulated in Kane's equation of motion that was effective for the dynamic analysis of multi-segment. This experiment was a case study in which one male athlete (age: 23yrs, height: 154.4cm, weight: 64.5kg) from K University was selected The system of a simulation included a multi-segment system that had one degree of freedom and one generalized coordinate for the shank segment angle. The reference frame was fixed by the Nonlinear Trans formation (NLT) method in order to set up a fixed Cartesian coordinate system in space. A weightlifter lifted a 90kg-barbell that was 75% of subject's maximum lifting capability (120kg). For this study, six cameras (Qualisys Proreflex MCU240s) and two force-plates (Kistler 9286AAs) were used for collecting data. The motion tracks of 11 land markers were attached on the major joints of the body and barbell. The sampling rates of cameras and force-plates were set up 100Hz and 1000Hz, respectively. Data were processed via the Qualisys Track manager (QTM) software. Landmark positions and force-plate amplitudes were simultaneously integrated by Qualisys system The coordinate data were filtered using a fourth-order Butterworth low pass filtering with an estimated optimum cut-off frequency of 9Hz calculated with Andrew & Yu's formula. The input data of the model were derived from experimental data processed in Matlab6.5 and the solution of a model made in Kane's method was solved in Matematica5.0. The conclusions were as follows; 1. The torque motor of the shank with 246Nm from this experiment could lift a maximum barbell weight (158.98kg) which was about 246 times as much as subject's body weight (64.5kg). 2. The torque motor with 166.5 Nm, simulated by angular displacement of the shank matched to the experimental result, could lift a maximum barbell weight (90kg) which was about 1.4 times as much as subject's body weight (64.5kg). 3. Comparing subject's maximum barbell weight (120kg) with a modeling maximum barbell weight (155.51kg) and with an experimental maximum barbell weight (90kg), the differences between these were about +35.7kg and -30kg. These results strongly suggest that if the maximum barbell weight is decided, coaches will be able to provide further knowledge and information to weightlifters for the performance improvement and then prevent injuries from training of weightlifters. It hopes to apply Kane's method to other sports skill as well as weightlifting to simulate its motion in the future study.

Evaluation on Motion Features of the World's Second Archer during Back-Tension in Archery (양궁 백 텐션 국면에서 최우수 양궁선수의 동작특성 평가)

  • Yi, Jae-Hun;Hah, Chong-Ku;Ryu, Ji-Seon;Kim, Ki-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.197-207
    • /
    • 2007
  • It has been reported that Back-Tension played a significant role in archery (Lee & Bondit, 2005; Kim, 2007) but there are a few researches related Back-Tension in Korea recently. Therefore, the purpose of this study was to investigate archery back tension technique for the second ranked archer in the World and to find ways to improve performance. A subject(height: 185cm, mass: 82kg, years: 21yrs, careers: 12yrs) who is a number of national team and the second ranked archer in the World authorized by FITA (Federation Internationale de Trial Arc) was perticipated in this experiment. When shooting 60 shots($12{\times}5$), shooting motions were recorded with 7 infrared cameras and 2 ultrahigh-speed cameras. A QTM and an Auto Track were used to acquire raw data. The sampling rates of both cameras were 200 Hz. and 1000 Hz. respectively and data were filtered using a fourth order Butterworth low pass filtering with a cutoff-frequency of 30Hz. The parameters were calculated with Matlab6.5 and analyzed with SPSS11.0. After Pearson's correlations between 8 parameters were analyzed, 5 parameters from 13parameters that affected records were analyzed with multiple regression analysis (Enter order: x1, x2, x3, x4, x5). The results were as follows: 1. Comparing between parameters according to scores, the patterns of horizontal and vertical angular velocity(av.) of scapular relative angle was different between 8 score and 9 or 10 scores. 2. The correlations of parameters that affected records were a horizontal av.(x1, p=.032<.05) and a vertical av.(x3, p=.033<.05) of scapular from release to delivery in KB back-tension (anchoring-delivery). 3. The decision coefficients(R2) of above two parameters and three parameters selected by experts that may affect record, that is, an absolute trunk angle(x4) from in KKC back-tension (anchoring-release) and a horizontal relative scapular angle(x2) and an absolute trunk angle(x5) from release to delivery in KB back-tension were 7.7%(x1), 0.1%(x2), 8.5%(x3), 0.7%(x4) and 0.9%(x5) in sequence. 4. The multiple regression equation was a y= -1.16E-2 x1 + 0.109 x2 + 3.437E-2 x3 + 6.139E-2 x4 + 0.117 x5 + 3.420 In conclusion, a total contribution was low, that is, R2(17.9%) suggested that on the one hand, Lim's motion may not depend on a certain factor because his postural factors affected shooting motion are some stable on the other hand, unknown factors may exist(e.g. psychological, physiological factors etc.). Further study of EMG patterns of muscles and anatomic consideration related to shoulder girdle and scapular bones may help to identify mechanism of Back-Tension.

Analysis of golf swing motion for specific properties of club shaft (클럽 샤프트(Club Shaft) 특성에 따른 골프 스윙(Golf Swing)동작 분석)

  • Kim, Sung-Il;Kim, Ky-Hyoung;Kim, Hyung-Soo;Lee, Hyun-Seob;Kim, Jin-Uk;Ahn, Chan-Gyu;Kim, Hee-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2002
  • The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF