• Title/Summary/Keyword: Burst

Search Result 1,586, Processing Time 0.031 seconds

Consideration on Design and Management of Flexible Hose through the Case Study of Chlorine Leak (염소 누출 사고사례연구를 통한 Flexible hose 설계 및 관리 방안 고찰)

  • Park, Suyoul;Yim, Ji-pyo
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • This research was performed to propose domestic standard for design and management of flexible hose by analyzing chlorine leak caused by breakage of the hose in Ulsan, 2018. The leak had multiple causes but this paper focuses on analyzing the cause of breakage of flexible hose, the direct cause. According to the analysis, flexible hose that the company of the accident used for chlorine transfer was inappropriate in several aspects including material and wall thickness. And even pressure test had been conducted below operating pressure. Upon investigation on five companies that handle chlorine in Ulsan, four companies were using inappropriate flexible hose for chlorine transfer. Since there is no domestic standard for the design of flexible hose for chlorine transfer at present, it is hard to examine its design adequacy. Design standard of flexible hose used in chlorine transfer that is applicable domestically is proposed based on this research. It will contribute to the reduction in risk of breakage of the hose if the proposed standard could be applied in design and examination of flexible hose.

Comparative Study of Mechanical and VOC Properties According to Manufacturing Conditions of Glass Fiber/Bamboo Fiber/PP Composites (유리섬유/대나무섬유/PP 복합재의 제조 조건에 따른 기계적 및 VOC 특성 비교 연구)

  • Lee, Su-kyoung;Park, Tae-sung;An, Seung-kook
    • Textile Coloration and Finishing
    • /
    • v.33 no.3
    • /
    • pp.153-160
    • /
    • 2021
  • In this study, composite materials were prepared by varying the content of glass fiber and bamboo fiber in PP/glass fiber/bamboo fiber. Experiments were conducted to confirm the mechanical properties(tensile, impact and burst strength) and volatile organic compound content of the bamboo fiber composite prepared under these conditions. An improvement in the main properties was observed at a fiber content of 30wt%. When the fiber fraction was increased above 30wt%, the mechanical properties tended to decrease due to the agglomeration of fibers at higher load fractions. In addition, the content of volatile organic compounds increased as the content of bamboo fibers increased, which is thought to be due to the volatile organic compounds generated during the manufacturing process of the composite material being present in the composite material without escaping from the pores of the bamboo fibers and volatilizing at a certain temperature. As a result of confirming the physical properties of the composite, it is considered that the optimal mixing condition is 30wt% of bamboo fiber for the composite produced by varying the amount of bamboo fiber composite. In the future, it is thought that follow-up experiments to confirm and improve the pre-treatment conditions for reducing the content of volatile organic compounds in the manufactured composite material are possible.

A Study of Critical Items and Related Standards on Designing for Passive Apartments (패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구)

  • Lee, Myoung-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

An Analysis on Japanese Recession Between 1993 and 2002 (1993~2002년 일본불황에 대한 연구)

  • Yoon, Hyung-Mo
    • International Area Studies Review
    • /
    • v.13 no.2
    • /
    • pp.168-188
    • /
    • 2009
  • Japanese economy suffered from a great recession for one decade between 1993 and 2002, because of the bubble bursting. Recently, a similar situation broke out in the USA and spread throughout the world. This paper investigated the effects of economic policy on the Japanese depression in order to find out how the recession, caused by financial crisis, can be reasonably removed. The analysis of documentary records indicate that there exists an optimum rate in government debt and the point in time of economic policy is decisive. Statistical studies with a VAR model and a State Space Model suggest that government expenditures affect the growth rate of national product but with a short term and it has a time lag of a half year. Income tax has a grievous negative effect on the growth rate with a long term and it works without a time lag. Therefore the increasing of taxation should be put into force very carefully. However private investment is a determinate factor for the recovery of depression.

Visible light-cured glycol chitosan hydrogel dressing containing endothelial growth factor and basic fibroblast growth factor accelerates wound healing in vivo

  • Yoo, Youngbum;Hyun, Hoon;Yoon, Sun-Jung;Kim, So Yeon;Lee, Deok-Won;Um, Sewook;Hong, Sung Ok;Yang, Dae Hyeok
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.365-372
    • /
    • 2018
  • Wounds that heal with excessive scar formation result in poor functional and aesthetic outcomes. To address this, in our study, visible light cured glycol chitosan (GCH) hydrogels containing endothelial growth factor (EGF) and basic fibroblast growth factor (bFGF) were prepared (GCH-EGF, GCH-FGF and GCH-EGF/FGF) and evaluated their efficacies on the improvement of wound healing in vivo. In vitro release test showed that the growth factors were released in a sustained manner along with initial burst for 24 h. In vitro cell proliferation assay of L-929 mouse fibroblast cell line resulted in the superior ability of GCH-EGF/FGF on the rate. In vivo results demonstrated that the growth factor loaded GCHs further enhanced wound healing compared with GCH. In particular, GCH-EGF/EFG showed the most remarkable wound healing effect among the samples.

Performance Evaluation of Smoothing Algorithm for Efficient Use of Network Resources in IoT environments (IoT 환경에서 네트워크 자원의 효율적인 사용을 위한 스무딩 알고리즘의 성능평가)

  • Lee, MyounJae
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.2
    • /
    • pp.47-53
    • /
    • 2021
  • In order to transmit video data stored in servers with limited bandwidth in IoT environments to many clients, a transmission plan must be established by considering factors such as the number of transmission rate changes, peak transmission rate, and transmission rate changes. This transmission plan is called smoothing, and includes CBA that minimizes the number of transmission rate increases, MCBA that minimizes the number of transmission rate changes, and MVBA to minimize the transmission rate changes. In this work, to evaluate the performance of the proposed algorithm[16], we compare the proposed algorithm with the existing smoothing algorithms with the peak rate, the number of transmission rate changes, the rate increase, the peak rate utilization, and the average transmission rate with various video data and buffer sizes. The evaluation results show that the proposed algorithm helps to efficiently use the server's finite network resources by establishing a transport plan with the lowest average transfer rate.

Does transcutaneous electrical nerve stimulation affect pain, neuropathic pain, and sympathetic skin responses in the treatment of chronic low back pain? A randomized, placebo-controlled study

  • Yaksi, Elif;Ketenci, Aysegul;Baslo, Mehmet Baris;Orhan, Elif Kocasoy
    • The Korean Journal of Pain
    • /
    • v.34 no.2
    • /
    • pp.217-228
    • /
    • 2021
  • Background: The purpose of this study was to assess the effectiveness of transcutaneous electrical nerve stimulation (TENS) in chronic low back pain and neuropathic pain. Methods: Seventy-four patients aged 18-65 with chronic low back pain were included in the study. Baseline measurements were performed, and patients were randomized into three groups. The first group received burst TENS (bTENS), the second group conventional TENS (cTENS), and the third group placebo TENS (pTENS), all over 15 sessions. Patients' visual analogue scale (VAS) scores were evaluated before treatment (preT), immediately after treatment (postT), and in the third month after treatment (postT3). Douleur Neuropathique 4 Questions (DN4), the Modified Oswestry Low Back Pain Disability Questionnaire (MOS), the Beck Depression Inventory (BDI), and sympathetic skin response (SSR) values were also evaluated preT and postT3. Results: A statistically significant improvement was observed in mean VAS scores postT compared to preT in all three groups. Intergroup comparison revealed a significant difference between preT and postT values, that difference being assessed in favor of bTENS at multiple comparison analysis. Although significant improvement was determined in neuropathic pain DN4 scores measured at postT3 compared to preT in all groups, there was no significant difference between the groups. No statistically significant difference was also observed between the groups in terms of MOS, BDI, or SSR values at postT3 (P > 0.05). Conclusions: bTENS therapy in patients with low back pain is an effective and safe method that can be employed in short-term pain control.

Deformation and permeability evolution of coal during axial stress cyclic loading and unloading: An experimental study

  • Wang, Kai;Guo, Yangyang;Xu, Hao;Dong, Huzi;Du, Feng;Huang, Qiming
    • Geomechanics and Engineering
    • /
    • v.24 no.6
    • /
    • pp.519-529
    • /
    • 2021
  • In coal mining activities, the abutment stress of the coal has to undergo cyclic loading and unloading, affecting the strength and seepage characteristics of coal; additionally, it can cause dynamic disasters, posing a major challenge for the safety of coal mine production. To improve the understanding of the dynamic disaster mechanism of gas outburst and rock burst coupling, triaxial devices are applied to axial pressure cyclic loading-unloading tests under different axial stress peaks and different pore pressures. The existing empirical formula is use to perform a non-linear regression fitting on the relationship between stress and permeability, and the damage rate of permeability is introduced to analyze the change in permeability. The results show that the permeability curve obtained had "memory", and the peak stress was lower than the conventional loading path. The permeability curve and the volume strain curve show a clear symmetrical relationship, being the former in the form of a negative power function. Owing to the influence of irreversible deformation, the permeability difference and the damage of permeability mainly occur in the initial stage of loading-unloading, and both decrease as the number of cycles of loading-unloading increase. At the end of the first cycle and the second cycle, the permeability decreased in the range of 5.777 - 8.421 % and 4.311-8.713 %, respectively. The permeability decreases with an increase in the axial stress peak, and the damage rate shows the opposite trend. Under the same conditions, the permeability of methane is always lower than that of helium, and it shows a V-shape change trend with increasing methane pressures, and the permeability of the specimen was 3 MPa > 1 MPa > 2 MPa.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.