• Title/Summary/Keyword: Bundle Program

Search Result 40, Processing Time 0.023 seconds

Behaviors of the Spacers on the Galloping of Power Transmission Lines

  • Kim, Hwan-Seong;Nguyen, Tuong-Long;Byun, Gi-Sig
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.128-133
    • /
    • 2003
  • In this paper, we have proposed a method by using virtual simulation to calculate the behaviors of spacers to avoid conductor galloping with the hanging composite polymer spacer between conductors on different phases. We have considered with three types of modeling considerations for the analysis of galloping in power transmission lines, such as iced-single conductors without spacer, iced-single conductors with spacers, and iced-two bundle conductors with spacers. In simulation, the finite element method is used to calculate the structural response with geometric nonlinear behavior. The iced conductor is modeled by two beam-element faces with which it is connected. The ANSYS program is applied too. First, the calculation results show that the two beam-element model is very suitable to make a virtual simulation. Second, the amplitude of conductor galloping is reduced after hanged spacers. Third, when number of spacer is increased, the maximum magnitude of natural frequency of iced conductor will reduce. Final, the behaviors of spacers are verified in viewpoint of standard cases.

  • PDF

A Study on the Performance of Rotary Heat Exchanger using Aluminum Finned Copper Tube Heat Pipe (동관-알루미늄 휜 회전형 히트파이프 열교환기의 성능에 관한 연구)

  • Park, K.H.;Lee, K.W.;Lee, K.J.;Chun, W.P.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.7-12
    • /
    • 2000
  • The purpose of this study is to develop heat transfer analysis program of heat pipe elements and design a revolving heat pipe exchanger by the performance experiment of hot air production by means of middle-temperature waste heat. Experimental variables are the revolution per minute, normal velocity of inlet air and the temperature of waste heat. The revolving heat exchanger has designed as $2^{\circ}$ in inclination angle of heat pipe bundle and as 20% in working fluid quantity and as water in working fluid. Experimental value of the total heat transfer coefficient was $20w/m^2-^{\circ}C$

  • PDF

Study on the Fluid-elastic Instability and Turbulence Excitation for the Steam Generator Tube (증기발생기 전열관의 유체탄성불안정성 및 난류가진 특성 연구)

  • 유기완;박치용;박수기;이종호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1400-1405
    • /
    • 2001
  • In this study, an analysis program to assess the susceptibility of steam generator tubes due to the flow-induced vibration was developed. Analysis of fluid-elastic instability and random turbulence excitation for the U-tube bundle in CE-type steam generator was accomplished. The effective mass distribution along the U-tube was obtained to calculate the natural frequency and dynamic mode shape. Finally, stability ratios and rms vibration amplitude for selected tubes are obtained.

  • PDF

Optimizing the design factors of the head-fed type combine(I) -Estimation of the threshing drum torque curve- (자탈형 콤바인 탈곡부 설계요인(設計要因)의 적정화(適正化)를 위한 연구(I) -급동축(扱胴軸) 토오크 파형의 추정(推定)-)

  • Nam, S.I.;Chung, C.J.;Hosokawa, A.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.3
    • /
    • pp.42-49
    • /
    • 1987
  • The threshing action of the head-fed type threshing unit occurs mainly by the impact between threshing tooth and grains. It may be therefore the most fundamental step to calculate the time and order of the occurrance of impact by the tooth for predicting the performance of threshing unit. The threshing teeth arrangement was defined by length and diameter of threshing dram, number of spiral arrays, number of threshing teeth by kind per one spiral array, number of windings of spiral array around the threshing drum, delay angle of impact line. The linear equations for locus of left and right margin of paddy bundle, spiral array, impact line on the development figure of the threshing drum were expressed by fastors of the threshing teeth arrangement. In the computer program, the teeth which inflict impact were searched successively along the impact line. Searching range and impact condition were defined by the relation between four linear equations. If the impacting tooth was found, time and the kind of threshing tooth was derived from the coordinate of the threshing tooth. At this time the unit torque curve was accumulated on the array of computer memory. At last the completed torque curve of threshing drum shaft was described on the computer screen. Remarkably the peack valae and fluctuation of torque curve was decreased by adopting the delay angle of impact line.

  • PDF

Development of the S/G TSP Clogging Image Analysis Algorithm (증기발생기 유로홈막힘 사진판독 알고리즘 개발)

  • Cho, Nam Cheoul;Kim, Wang Bae;Moon, Chan Kook
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.8-14
    • /
    • 2011
  • The clogging of the flow area at the tube support plates(TSPs), especially at the upper TSPs results in the water level oscillation of a steam generator during normal operation. A reduction of the TSP flow area causes to increase in pressure drop within the two-phase flow zone, which destabilizes the boiling flow through the tube bundle. This phenomenon was occasionally observed at a few domestic and foreign nuclear power plants. One of the methods for defining the flow area clogging is visual inspection, which is the most effective inspection method. The results of the visual inspection for TSPs' flow area are clogging images on TSPs' quartrefoil lobes. These images are complexly distorted due to lens aberration and external factors like the distance to a subject and angle etc. In this work, we developed the analysis algorithm for clogging image of the TSP flow area of steam generators. For this purpose, we designed an image verification device applicable to the camera employed in the field for visual inspection and then, we demonstrated the validity of image analysis algorithm by using this device and commercial autoCAD program.

Comparison of Supraspinatus Muscle Architecture During Three Different Shoulder Strengthening Exercises Using Ultrasonography

  • Moon, Il-young;Lim, One-bin;Cynn, Heon-seock;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Background: Strengthening the supraspinatus is an important aspect of a rehabilitation program for subacromial impingement and tendinopathy. Many authors recommended empty-can (EC), full-can (FC), and prone full-can (PFC) exercises to strengthen the supraspinatus. However, no ultrasonography study has yet investigated supraspinatus muscle architecture (muscle thickness; MT, pennation angle; PA, fiber bundle length; FBL) in relation to supraspinatus strengthening exercises. Objects: The purpose of this study was to compare the architecture (MT, PA, and FBL) of the supraspinatus muscle during three different types of exercises (EC, FC, and PFC) using diagnostic ultrasound. Methods: Participants performed three different exercises: (A) EC; the arm was maintained at $60^{\circ}$ abduction with full internal rotation in the sitting position, (B) FC; the arm was maintained at $60^{\circ}$ abduction with full external rotation in the sitting position, and (C) PFC; the arm was maintained at $60^{\circ}$ abduction with full external rotation in the prone position. Ultrasonography was used to measure the MT, PA and FBL of the supraspinatus. One-way repeated analysis of variance with Bonferroni's post-hoc test was used to compare between the three exercises and the initial position of each exercise. Results: Compared with each initial position, the FC exercise showed the greatest mean difference in muscle architecture properties and the PFC exercise showed the least mean difference. Conclusion: The findings suggest that the FC exercise position may have an advantage in increasing the amount of contractile tissue or producing muscle power and the PFC exercise position may be useful in a rehabilitation program because it offers the advantage of maintaining the muscle architecture properties.

A Study on Environmental Design Method based on Open Narrative Structure - A Case of Designing of Arirang Culture Park - (열린 내러티브 구조를 이용한 환경설계 방법 연구 - 용산 아리랑 문화공원을 설계사례로 -)

  • 이상경;조경진
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.12-27
    • /
    • 2003
  • The purpose of this study is to look for an environmental design method based on open narrative structure, and to promote various experiences and interpretations of space through user's engagements. That is to say, the designer does not lead specific events through separate Boning but using the continuous open composition users are provided with margins for their imaginations. Spatial formulation through open narrative structure gives us various thoughts and it plays an important role in making a sequential space. Like an abstract painting, it is a complex story making or arranging a montage of images containing stories that elicit the reader's engagement through diverse interpretations. Like this, open composition exists in an ambiguous state and it is possible to interpret unfinished‘evolving work’within it. Utilizing open narrative structure, this study attempts to apply the idea of sequencing and open composition in the case of designing Arirang Culture Park. Open composition should induce various engagements by users and could be a medium which organically connects nature, culture and people. The spatial strategies of‘ambiguity’ and‘transparency’are like a bundle of complex and heterogeneous factors. Finally, the study focuses on the ‘integration’of the main ideas that compose multilayered space. ‘Voidness’and‘thickening’are also used for spatial strategies in open narrative structure. As alternative plans for undecided programs of the space, the voidness can be a strategic design program with flexibility about changes of futures. Also, thickening can be a strategic design program for functional reinforcement of the space, for the dramatic effects and for the generation of incidental events. Although both voidness and thickening seem paradoxical, we can see they are similar in the way that both focus on various spatial uses and by how they do not function as one-to-one correspondence, but as multiple correspondences. Therefore, open narrative structure is possible to apply in designing space and it can be an alternative design strategy for inducing multiple interpretations of space.

A Study on the Frame Sensor Modeling Using Standard Interface (표준 인터페이스를 적용한 프레임 센서 모델링에 관한 연구)

  • Kwon, Wonsuk;Choi, Sunyong;Lee, Yongwoong
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • Until recently, photogrammetric applications for processing the satellite images and remotely sensed data have been used in different structure of functions and interfaces for sensor modeling by each developer. Thus, a standardized utilization procedure was necessary to solve the problems, such as expandability, cost, inefficiency of sources which were resulted from different approaches. Therefore, National Geospatial Intelligence Agency (NGA) provided unified interfaces by developing Community Sensor Model (CSM) to sensor models in same way. In this study, we suggested the method of design and analyzed main functions needed modeling for the frame sensor using CSM Application Program Interface (API) provided by NGA. We also applied the designed structure to the modeling. The implemented CSM was verified by groundToImage and imageToGround. In the future, the active R&D is expected with using CSM due to the cost saving effect of software development and remarkable expandability of sensor.

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line (765kV 시험선로를 이용한 전기환경장해 특성연구)

  • Kim, Jeong-Boo;Jo, Seong-Sae;Shin, Goo-Yong;Lee, Dong-Il;Yang, Kwang-Ho;Ahn, Hee-Sung;Bae, Jeong-Hyo;Koo, Ja-Yoon;Min, Seok-Weon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF