• 제목/요약/키워드: Bullet-Proof Test

검색결과 4건 처리시간 0.017초

한국형 전술차량 방탄유리 환경 및 방호력 시험 적용 기법 연구 (A Study of Environment & Bullet-Proof Capability Test Method for KLTV's Transparent Armour)

  • 박진원;박영찬;김선진
    • 한국군사과학기술학회지
    • /
    • 제21권1호
    • /
    • pp.69-73
    • /
    • 2018
  • Korean-peacekeeper's transparent armors in Iraq showed delamination, cracking and clouding a decade ago. And there were also similar deterioration recurrences in KLTV during the operational test a few years ago. Also, the differences between operational capability & lab Bullet-proof test condition, and insufficiency of military protection spec resulted in incomplete bullet-proof results. Moreover, although so many ground weapon systems have been developed, there were not secure test & evaluation codes to verify transparent armoured glasses equal to advanced-overseas products. So in this study, first, environmental test codes were established that all tests should be carried out as the application of only one specimen with newly adopted thermal shock test instead of completing each test with different one. Second, protection standards were integrated through the analysis of global developed country's specifications and reinforced as adding to the real mock-up condition if vehicle's glasses are smaller than standard specimen. Hereby, by applying to test-codes which including actual operational & vehicular conditions, the gap between development test and operational environment was minimized.

이원 추진 시스템 고압 시험시의 파열 안전성 고찰 (Rupture Safety Assesment of Bipropellant Propulsion System at High Pressure Testing)

  • 장세명;한조영
    • 한국항공우주학회지
    • /
    • 제38권6호
    • /
    • pp.605-611
    • /
    • 2010
  • 정지궤도위성인 통신해양기상위성은 2010년 발사 예정인데, 관련된 일련의 성능 시험중에는 수백 기압의 헬륨 가스로 채워진 추진계 탱크의 고압 내구 시험도 포함되어 있다. 이 논문에서는 시험 시스템에 최악의 사고가 일어날 경우를 대비하여 그 위험도를 계산하여 보았다. 두 가지 시나리오가 있는데, 첫째는 310 기압의 헬륨 탱크가 현재의 시험챔버에서 일시에 파열하는 경우, 둘째는 116 기압의 감압된 헬륨 탱크가 방탄유리로 보호되고 있는 방에서 파열하는 경우를 가정해 보았다. 폭발파 전파 이론과 전산 수치 모사를 통하여, 제한된 공간에서 반사되는 파동의 역학을 매우 복잡한 비정상 유동 물리에 대하여 분석하였다.

Al합금과 Ti합금의 방탄특성에 관한 실험적 연구 (An Experimental Study on the Characters of Bullet Proof for Al and Ti Alloy)

  • 손세원
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.113-120
    • /
    • 2005
  • In order to investigate the characteristics of penatration and the effect of surface treatment in A15052-H34, Al5082-Hl31 and titanium alloy laminates which were treated by anodizing and PVD(Physical Vapor Desposition) method, ballistic tests were conducted. Thickness of surface membrane in A15052-H34, Al5082-Hl31, were $25{\mu}m$ and that of titanium $0.9{\mu}m$ respectively. Surface hardness test was conducted using micro Vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit(V50), a statistical velocity with $50\%$ probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are observed from the results of V50 test and Projectile Through Plate(PTP) test at velocities greater than protection ballistic limit, respectively. Present experimental results derived from this research help to optimize laminate impact behavior by varing the laminate thickness and surface treated materials.

탄소나노튜브(CNT)를 혼입한 초고성능 콘크리트(UHPC)의 고고도 전자기파(HEMP) 방호성능 평가 (Evaluation on High Altitude Electromagnetic Pulse(HEMP) Protection Performance of Carbon Nanotube(CNT) Embedded Ultra-High Performance Concrete(UHPC))

  • 정명준;홍성걸
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.151-161
    • /
    • 2019
  • In this study, to evaluate the High Altitude Electromagnetic Pulse(HEMP) protection performance of UHPC/CNT composites by the content of Carbon nanotubes(CNTs), Electromagnetic Shielding Effectiveness(SE) test was performed based on MIL-STD-188-125-1. And the results were verified by applying the Antenna theory. In the case of UHPC with a thickness of 200 mm mixed with 1 % CNT of cement weight, the SE was 28.98 dB at 10 kHz and 45.94 dB at 1 GHz. Then the Scabbing limit thickness for bullet proof was computed based on the result of compressive strength test which was 170 MPa, and it was examined whether it satisfied the HEMP protection criteria. As a result, the required HEMP shielding criteria were satisfied in all frequency ranges as well as the scabbing limit thickness was reduced by up to 43 % compared with that of ordinary concrete.