• Title/Summary/Keyword: Built-up T

Search Result 132, Processing Time 0.03 seconds

A Study on the Role of Fire Fighting and Rescue Squad in terms of Fire Investigation (화재조사 측면에서의 화재진압 및 구조대원의 역할에 대한 연구)

  • Lee, Seung-Hun;Lee, Chang-U
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.461-470
    • /
    • 2012
  • Fire scene is mostly destroyed by the flames but fire fighter's fire suppression and rescue activities also destroys a substantail portion. Structures and furnitures which has already become weaken can be easily damaged. Or when structures built up by moving to another location, it's very hard to restore the original state. Also if it is restored, the object has no evidence that it has existed. In all scenes, the scene can't be preserved when quick extinguishment, rescue activities and preventation of fire spread is needed. On this paper, it reviewed the notes about the possibility of field damage by fire suppression and rescue squad's activities. Also it has reviewed the notes how to minimize the field damage by putting out fires and rescue activities by observing the precautions. The reviewed information will help to make guidelines for preserving the scene. By this, it is expected to make a field study exactly by collecting more valid evidence.

  • PDF

A study on Dental Technicians stress (치과기공사의 스트레스 연구)

  • Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.16 no.1
    • /
    • pp.105-113
    • /
    • 1994
  • This study attempted to find out how much stress Dental Technicians of working in Dental Laboratory have built up in the midst of their daily lives are according to their sex, age, duration of work and their kinds of positions. After self-administered questionnaire were distributed by direct to 230 technicians samplely selected from dental laboratories in Seoul and Pusan of whom 163 technicians responded from october 1 through october 13, 1994. Analysis of the data was processed by t-test, $X^2$-test, ANOVA. This results are as follows. 1. Levels of Stress of the total 163 respondents by sex is not higher among male than female(p>.05). 2. Levels of stress - 36.2%(74 Dental technicians) of all Dental technicians were in stress on the whole and 9.2%(15 Dental technicians) of them were in a serious situation by accumulated stress. 3. Realization of stress - 10.1%(16 Dental technicians) of the dental technicians and 89.9%(143 Dental technicians) were found out to be in a dangerous sign or in a situation by accumulated stress. Further studies which a big size and a delicate method of measuring their general characteristics are needed.

  • PDF

Reconstruction of Buildings from Satellite Image and LIDAR Data

  • Guo, T.;Yasuoka, Y.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.519-521
    • /
    • 2003
  • Within the paper an approach for the automatic extraction and reconstruction of buildings in urban built-up areas base on fusion of high-resolution satellite image and LIDAR data is presented. The presented data fusion scheme is essentially motivated by the fact that image and range data are quite complementary. Raised urban objects are first segmented from the terrain surface in the LIDAR data by making use of the spectral signature derived from satellite image, afterwards building potential regions are initially detected in a hierarchical scheme. A novel 3D building reconstruction model is also presented based on the assumption that most buildings can be approximately decomposed into polyhedral patches. With the constraints of presented building model, 3D edges are used to generate the hypothesis and follow the verification processes and a subsequent logical processing of the primitive geometric patches leads to 3D reconstruction of buildings with good details of shape. The approach is applied on the test sites and shows a good performance, an evaluation is described as well in the paper.

  • PDF

Ionic Conductivity by A Complex Admittance Method

  • Chy Hyung Kim;Eung Dong Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.6
    • /
    • pp.495-500
    • /
    • 1989
  • The ionic conductivity of polycrystalline, glass, and glass-ceramic silicates was measured using two-terminal AC method with blocking electrode over a frequency range of 100 Hz to 100 KHz in the temperature range of $200^{\circ}C$ to $320^{\circ}C$. Analysing the capacitance (C), susceptance (B), impedance (Z), and conductance (G) under the given conditions, an equivalent circuit containing temperature and frequency dependent component is proposed. Higher capacitance could be observed in the low frequency region and on the improved ionic migration conditions i.e., at higher temperature in a better ionic conductor. Also the electrode polarization built up at the electrode-specimen interface could be sorted out above 10 KHz. However, grain boundary contribution couldn't be extracted from the bulk resistance over the frequency range measured here.

Numerical Analysis and Experiments for the Stratification of the Hot Water Storage (수축열조의 온도 계층화에 대한 수치해석 및 실험적 연구)

  • Yang, Y.S.;Baek, N.C.;Kim, H.J.;Yoo, J.I.;Lee, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.187-197
    • /
    • 1993
  • In this study, the numerical analysis and experiments of the hot water storage using the thermal stratification techniques were carried out. The CPU time for a typical run of the the thermal stratification up to 900 seconds took one week for a $81{\times}31$ mesh size and 10 days for a $118{\times}31$ mesh size, respectively, for a cylindrical shape of the storage. In the initial stage, the numerical results were in favorable agreement with the experimental results, but it showed that the temperature gradients in the storage decreased gradually with time. It was also found that the increase of ${\delta}t$ decreased the convergent speed due to the intensive fluctuation of the velocity field in every iteration. The increase of numbers of grids is projected to forecast a more accurate result, but it made the computing time longer and woul slow down convergence. At the experiments of the flow visualization, it was confirmed that the thermal stratification was apparently built up due to the installation of diffuser at the lower part of the storage. Thus, the thermal performance of the storage could be improved by installing the diffusers at the inlet and outlet.

  • PDF

Design of Magnetic Systems for SNUT-79 Tokamak (SNUT-79 토카막의 자장 계통 설계)

  • Cheol Hee Nam;Sang Hee Hong;Kie Hyung Chung;Sang Ryul In
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 1984
  • A toroidal-field (TF) coil with a pure tension D-shape curve is designed for the confinement of high-temperature plasmas in the SNUT-79, which is a tokamak being built at Seoul National University. A toroidal assembly of 16 D-shape TF coils is designed to produce the magnetic field of up to 3T, of which ripples appear to be below 4% of the average toroidal field in the plasma region. Exact positions and currents in six equilibrium coils distributed symmetrically in the z=0 plane are found by the solution of a set of linear equations which is transformed from a Fredholm integral equation of the first kind. The decay indices resulted from equilibrium field indicate that the stability condition for vertical and horizontal displacements is satisfied.

  • PDF

Three-dimensional finite element simulation and application of high-strength bolts

  • Long, Liji;Yan, Yongsong;Gao, Xinlin;Kang, Haigui
    • Steel and Composite Structures
    • /
    • v.20 no.3
    • /
    • pp.501-512
    • /
    • 2016
  • High-strength structural bolts have been utilized for beam-to-column connections in steel-framed structural buildings. Failure of these components may be caused by the bolt shank fracture or threads stripping-off, documented in the literature. Furthermore, these structural bolts are galvanized for corrosion resistance or quenched-and-tempered in the manufacturing process. This paper adopted the finite element simulation to demonstrate discrete mechanical performance for these bolts under tensile loading conditions, the coated and uncoated numerical model has been built up for two numerical integration methods: explicit and implicit. Experimental testing and numerical methods can fully approach the failure mechanism of these bolts and their ultimate load capacities. Comparison has also been conducted for two numerical integration methods, demonstrating that the explicit integration procedure is also suitable for solving quasi-static problems. Furthermore, by using precise bolt models in T-Stub, more accurately simulate the mechanical behavior of T-Stub, which will lay the foundation of the mechanical properties of steel bolted joints.

Comparison to Soil Environment of Tricholoma matsutake and Sarcodon aspratus at Uljin Sokwang-ri Pinus densiflora for. erecta Uyeki Forest (울진 소광리 금강소나무림의 송이발생지와 능이발생지의 토양환경 비교)

  • Hur, Tae-Chul;Joo, Sung-Hyun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.20
    • /
    • pp.77-82
    • /
    • 2002
  • This study was carried out in order to produce useful material for the forest multiple use and forest protection by physico-chemical soil analysis of studied area in Sokwang-ri Forest Genetic Resource Protection Forest which was divided into in standard plots include Tricholoma matsutake and Sarcodon aspratus production forest. The result of physico-chemical soil analysis represented as following. The soil type of T. matsutake production forest was Dry brown forest soil(B1), while on the other hand the soil type of S. aspratus production forest was Moderately moist brown forest soil(B3). Between T. matsutake and S. aspratus production forest did not result in significant changes in soil pH(5.22-5.60) and soil depth(47cm), but available phosphorus, carbon, and nitrogen contents were different results. CN ratio of the fairy ring of T. matsutake was quite lower than that in S. aspratus production forests, which indicated that T. matsutake production forest was built up in the relatively immature soils which contain little organic matter. Generally, it was predicted that Pinus densiflora for. erecta forest succeeded to deciduous tree forest in stable soil environments. To conserve these T. matsutake and S. aspratus production forest, the contents of available phosphorous and exchangeable cation should be increased by continuous soil environment management and it should be established the secondary growth forests of old aged Pinus densiflora for. erecta trees as soon as possible.

  • PDF

A Study of Evaluation Indices for Selecting Castle Remains Maintenance and Restoration Sections (성곽유적의 정비복원(整備復元) 대상구간 선정을 위한 평가지표 연구)

  • Kim, Hong-Gon;Choi, Key-Soo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Most of all Castle Remains in Korea were built on an axis of development with a scale of great magnitude. Because of its characteristics, the restoration and conservation plans should be phased in over medium and long term. There is no standards for evaluating the value of Castle Remains to set up the restoration and conservation sections. Some plans were set up through the value evaluation of its Castle Remains but those plans didn't have Evaluation System and different weight depending on different environment between Sanseong(mountain fortress) and Eupsung(fortress built in villages). To solve the limitation of Evaluation System of Castle Remains, this study try to approach in the Evaluation System methodology for selecting restoration sections. The results of its study follow below. First, this study drew the Evaluation Indices for selecting restoration sections of Castle Remains. There are three kinds of Elements(upper Index) and nine kinds of Evaluations(low Index). Second, Calculation of weight index by index on the questionnaire survey from expers through the relative importance analysis of AHP. Third, This study suggests the specific Evaluation System according to types; Sanseong(mountain fortress) and Eupsung(fortress built in villages);. Therefore, this study suggests standards to select the priority list for the restoration and conservation plan process and it can be used one of important standards in future plans.

Radiologic Assessment of Subsidence in Stand-Alone Cervical Polyetheretherketone (PEEK) Cage

  • Ha, Sung-Kon;Park, Jung-Yul;Kim, Se-Hoon;Lim, Dong-Jun;Kim, Sang-Dae;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.6
    • /
    • pp.370-374
    • /
    • 2008
  • Objective : Aim of study was to find a proper method for assessing subsidence using a radiologic measurement following anterior cervical discectomy and fusion (ACDF) with stand-alone polyetheretherketone (PEEK), $Solis^{TM}$ cage. Methods : Forty-two patients who underwent ACDF with $Solis^{TM}$ cage were selected. With a minimum follow-up of 6 months, the retrospective investigation was conducted for 37 levels in 32 patients. Mean follow-up period was 18.9 months. Total intervertebral height (TIH) of two fused vertebral bodies was measured on digital radiographs with built-in software. Degree of subsidence (${\Delta}TIH$) was reflected by the difference between the immediate postoperative and follow-up TIH. Change of postoperative disc space height (CT-MR ${\Delta}TIH$) was reflected by the difference between TIH of the preoperative mid-sagittal 2D CT and that of the preoperative mid-sagittal T1-weighted MRI. Results : Compared to preoperative findings, postoperative disc height was increased in all cases and subsidence was observed only in 3 cases. For comparison of subsidence and non-subsidence group, TIH and CT-MR ${\Delta}TIH$ of each group were analyzed. There was no statistically significant difference in TIH and CT-MR ${\Delta}TIH$ between each group at 4 and 8 weeks, but a difference was observed at the last follow-up TIH (p=0.0497). Conclusion : ACDF with $Solis^{TM}$ cage was associated with relatively good radiologic long-term results. Fusion was achieved in 94.5% and subsidence occurred in 8.1% by the radiologic assessment. Statistical analysis reveals that the subsidence seen later than 8 weeks after surgery and the development of subsidence does not correlate statistically with the change of the postoperative disc space height.