• 제목/요약/키워드: Built-in Refrigerator

검색결과 26건 처리시간 0.02초

혼합냉매의 성분비 조절을 통한 열펌프의 용량조절 (Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures)

  • 김민성;김민수;김용찬
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF

아파트 후면 베란다의 이용실태에 관한 연구 (A Study on Utilization of Apartment Rear Veranda)

  • 김수양
    • 한국실내디자인학회논문집
    • /
    • 제15호
    • /
    • pp.86-93
    • /
    • 1998
  • An Apartment Veranda is a transitive space which is being used for many different purpose. A Rear Veranda which is connected to the kitchen is an important space for the housekeeping work and it should be planned carefully to reflect the rational and functional designs. Therefore the objective of this research is to suggest a systematic basis for the practical space planning of the Rear veranda that meets the varied needs of consumers by examining its usage pattern through the analysis of the apartment occupant's behavior pattern stored item the degree of satisfaction and consumer requirements. The research was conducted mainly on apartments built after 1990. The following are the conclusions from the research : 1. Most of the research respondents were aware of the absolute need for the Rear veranda. But they expressed dissatisfaction with the space usage. This indicates that the Rear Veranda planning does not reflect the functionality of the space and concentrates on the idea of providing consumers a service space based on the size of the apartment instead. 2. Although the Rear veranda is used as the multipurpose housework space it is mainly used as the laundry and storage space. This shows a big deviation from the concept of the utility space. Because the behavior pattern associated with the Rear Veranda is largely influenced by the traditional life pattern the development of the Rear Veranda as an exclusive space for the housekeeping work. 3. According to a high frequency of the storage of the laundry related item in the Rear Veranda indicated by the research the Rear veranda is used as the laundry room as well as a auxiliary storage space by most people. The installation of gas range is expected to increase due to the expansion of the usage function of the Rear Veranda space. The installation of a specialized refrigerator to store the traditional food is demanded. 4. Consumers need more efficient and functional storage device because the temporary shelves are often being used as the storage device. The perception of the storage device is assumed to have been influence by the traditional life style.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

터보 냉동기용 핀튜브에 관한 연구 ( I ) - 응축 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator( I ) -for Condensation Hear Transfer-)

  • 조동현;한규일;김시영
    • 수산해양교육연구
    • /
    • 제5권1호
    • /
    • pp.31-44
    • /
    • 1993
  • Through the early 1900's, the evolution of the surface condenser was closely tied to the development of steam engine and the turbine. As the chemical and petroleum industries evolved in the 1900's, the use of surface condensers in many different processes. Today, industry uses condensers in many shapes and sizes. The actual condensation process occurs on the outside surface of tubes. The nature of this surface geometry affects the condenser's heat transfer performance. The first condensers were built with plain tubes. As tube manufacturing techniques advanced, manufacturers started making tubes with integral fins. In the 1940's, fin densities were limited to about 600 to 700 fins per meter(fpm) because of manufacturing procedure. Today new manufacturing techniques allow production of tubes with fin densities ranging from 750 to 1600 fpm. The integral-fin tubes investigated in this paper are nominally 19 mm diameter. Eight tubes have been used with trapezodially shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. For comparison, tests are made using a plain tube having the same inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Betty and Katz's theoretical modelis is used to predict the R-11 condensation coefficient on horizontal integral-fin tubes having 748, 1024 and 1299 fpm. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken at steady state. The observed heat transfer enhancement for the finned and grooved tubes significantly exceeded that to be expected on grounds of increased area. For the eight fin tubes and one plain tube tested, the best performance has been obtained with a tube having a fin density of 1299 fpm, and a fin bight of 1.2mm and 30 grooves.

  • PDF

한국전통옹기의 통기성에 관한연구 (Study about porous of Korean traditional pottery)

  • 김석호
    • 조형예술학연구
    • /
    • 제9권
    • /
    • pp.5-24
    • /
    • 2006
  • 인류가 살아남기 위해서 수렵과 채취를 하는 동안 저장을 위해 자연스럽게 생겨 난 그릇은 위대한 발명이었다. 현대에 와서 사회의 변화와 과학의 발달로 자연의 순수한 재료로 만들어지던 그릇과 각종 저장용기들이 플라스틱과 철이라는 새로운 재료들로 만들어져 생활의 편리함을 안겨주었다. 하지만 심각하게 늘어나는 환경문제로 인해 인류는 자연으로의 회귀를 추구하려는 경향들이 생겨났다. 그 대표적인 트렌드가 웰빙(well-being)이라고 할 수 있는데 이것은 결국 과학문명이 발달하기 전 우리선조들이 추구해왔던 삶으로 돌아가려는 것이라고 볼 수 있다. 우리선조들은 자연과 더불어 삶을 살았고 자연에 순응하면서 살았다. 집을 지을때도 자연의 일부로서 집을 짓고 자연과 닮은 집을 지었다. 사계절을 지내기 위해 음식을 저장하는 방법을 연구하여 집안 곳곳에 저장창고와 저장용기를 배치하였다. 현재를 살아가는 한국 사람들은 집집마다 냉장고에 김치를 보관한다. 하지만 조상들은 자연을 이용한 저장방법을 연구해 시와 때에 맞춰 음식을 먹을 수 있도록 했다. 웰빙 열풍과 함께 한국의 음식이 세계화 되고 있고, 그에 따라 선조들의 지혜에 대한 관심도 점점 증가하고 있다. 김치의 세계화로 김치를 저장했던 용기에 대한 관심이 그 예라고 할 수 있다. 본 연구는 예부터 발전해온 도기의 일종인 옹기의 발전사를 문헌을 통해 알아보고 과학적인 실험을 통해 선조들의 지혜가 담긴 옹기의 특성을 연구함으로서 옹기 장점과 필요성을 알리고 더 나아가 옹기의 특성을 활용한 친환경적인 기물의 개발에 힘쓰도록 유도함에 그 목적이 있다.론으로 재해석할 수 있는 민족적 표현임을 알 수 있다.다. 이러한 배경 아래 키키스미스의 작품 세계를 고찰하기 위해, 신체를 통해 의미의 지평이 열리는 객관적 방법을 모색한 결과, 기호학과 신체론에 대한 고찰이 필요하다는 사실을 인식하게 되었다. 즉 신체를 객관화하여 가장 기초적인 수준에서 표현적인 부분과 내용적인 부분을 구조적으로 나누어 그 관계에 의해 의미가 발생하게 되는 과정을 기호와 텍스트의 개념에서 시작하였다. 나아가 이 표현면과 내용면의 구조적인 결합방식을 그레마스(A. J. Greimas)의 구조의미론에서 다룸으로써 의미의 확장을 위한 토대론적 작업을 구축하였다. 한편, 신체론에서는 세계와의 관계항으로서 신체를 조망하게 해준 메를로-퐁티(Maurice Merleau-Ponty)의 현상학(Phenomenology)과 애브젝션(abjection)의 개념을 통해 해체와 파편의 신체를 전달하게 해준 줄리아 크리스테바(Julia Kristeva)의 논의가 구조의미론적 분석을 해석으로 확장시키는 데 중요한 기여를 하였다. 키키 스미스는 1980년대 중반 죽음에 대한 서사에서 시작된 이중화와 파편화의 신체로부터 상처받을 수 있는 신체의 비천함이 구체적으로 드러난 1990년대 그리고 상처의 치유에 이르는 종교와 신화로 이어지는 2000년대 이후의 과정을 보여주었다.을 알 수 있었다. 따라서 향후 부작용은 증가시키지 않으면서 국소제어율을 향상시키기 위한 노력이 필요하다. 것을 사료된다./Cip1}(-)/p27^{kip1}(-)$인 경우는 미만형인 경우(87.0%)가 장형(54.9%)

  • PDF

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.