• Title/Summary/Keyword: Built Environment

Search Result 1,982, Processing Time 0.032 seconds

A Study on the Application of As-Built Drawings for Updating Digital Maps (수치지도 수정.갱신을 위한 건설공사 준공도면 활용방안 연구)

  • Shin, Dong-Bin;Yu, Seon-Cheol
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.4
    • /
    • pp.37-45
    • /
    • 2008
  • Increased demand for the latest spatial information, it is necessary to study the complement current map updating systems for responding the diverse environment of the national territory information. This study suggests the way to update 1/5,000 digital maps with the application of as-built drawings based on current systems. This study compares current as-built drawings with digital maps, and consider intra and international related cases and regulations. This study also selects case areas based on different types of as-built drawings and updates digital maps with the application of as-built drawings. After the consideration of systems and regulations related to as-built drawings, the research results, including the improvement and the application of as-built drawings, are presented. It is expected that the foundation to provide more rapid and accurate geographic information can be achieved from the research result.

  • PDF

A Study on the Unification of the Grounding System of SeoulMetro (서울메트로 접지설비 표준화 방안 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1027-1036
    • /
    • 2007
  • Since the opening of the Seoul Metro in 1974, the electric railway passengers have been increased rapidly and as the advanced equipments(OC,PSD) were introduced, additional power facilities were built in a limited area for the comfortable transportation environment. Present grounding system were built according to old Electric equipment standards and all the electric signal, communication and electronic equipments were built only for the purposes of protecting building structure, people and electronic equipments. Grounding system which was additionally built in the limited area caused problems with the building structure and it caused secondary damages when earth fault happens. One of the problems is grounding system of the building structure; grounding system does not work properly since grounding equipments are not separated from each other. So, existing grounding system needs to be improved and unified grounding system in the building should be established. The purposed of this study is to analyze all the grounding systems that had been built in different year and to establish unified grounding system of Seoul Metro.

  • PDF

The method for the classification according to their kinds and the estimation of unit generation rate for promoting recycling of construction and demolition(c&d) debris (건설폐기물 재활용촉진을 위한 종류별 분류 및 발생원단위 산정 방안)

  • Lee, Hi Sun;Kim, Dong Sik
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.86-100
    • /
    • 2008
  • It is needed to classify the kinds of construction and demolition(c&d) debris to 6 catagories of waste concrete, waste asphalt concrete, waste wood, scraps, combustible waste and incombustible waste in order to properly do a separate discharge and to estimate unit generation rate in construction site. Also, in this case, the unit treating cost for mixed wastes should be applied with the unit treating cost for combustible waste. The construction standard materials estimation data is used for basic data for estimating unit generation rate. The mixed wastes in this data should be classified to waste wood, combustible waste and incombustible waste, and their ratio is obtained by using the unit generation rate of Asia Pacific Environment and Management Institute and Seoul Metropolitan Development Institute. The waste amounts generated from newly-built construction can be obtained from multiplying the loss rate by the amount of materials used from construction standard estimation data. Also, those from dismantling construction can be obtained by subtracting waste amount generated during newly-built construction from total input amount of materials in newly-built construction. Those in two cases can be used in construction site. It can be used for estimating the amount generated and establishing the treating plan in the case of setting up the policy of waste management and doing the environment impact assessment.

  • PDF

An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

EFFECT OF TURBULENCE AT INLET BOUNDARY ON AIR MOVEMENT IN A ROOM

  • Lee, Heekwan;Hazim B. Awbi
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.162-164
    • /
    • 2000
  • The numerical simulation of air movement in a room using CFD (Computational Fluid Dynamics) requires a complicated set of input data, This includes physical data, such as space geometry, characteristics of supply air flow and contaminant source, etc. as well as computational domain. Among the input data, the boundary conditions related to the inlet are particularly crucial in order to achieve accurate computation results, although there are many other parameters which may also affect the results. (omitted)

  • PDF

Comparisons and Analysis on Architectural Features of Seven Typical Traditional Dwellings in China

  • Tang, Si-Yi;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.5-13
    • /
    • 2014
  • The ancestors of China created various proper dwellings in the vast Chinese lands, according to distinct geographical environment, climate, and special local products. The purpose of this study is to compare features of 7 typical traditional Chinese dwellings in different areas from historical, geographical, structural and tinctorial aspects, in order to see what the differences are and rearrange them by these 4 different scales as estimate standards. By Comparing features between 7 traditional dwellings, advantages and disadvantages of them were found out. Not only natural terrain but also cultural mentality is an important factor that effected on the changes of regionality. The result showed that historical length in a certain extent reflected the differences between dwellings in different areas; there are more regular type dwellings in the northern China; dwellings in different structural material types following their regions; and, southern dwellings prefer natural and simple exterior colors. Also From construction aesthetics and culture perspective, Different cultures have cultivated and brought out different dwelling styles. Thus, protecting on traditional dwellings is of great necessities and this study will bring benefits in many aspects. For a further research, the result of this study can be utilized as the base data that suggest directions for effective Chinese residence planning in different areas meeting different demands.

A Study on the Development of the User Behavior Simulation Technology Using a Perceived Action Possibilities (내제된 행위 유발 가능성을 활용하는 사용자 행동 시뮬레이션 기술의 개발에 관한 연구)

  • Lee, Yun-Gil;Park, Chang-Hoon;Im, Dong-Hyuk
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.11
    • /
    • pp.1335-1344
    • /
    • 2014
  • In architectural design, the user is one of the most important factors for the design task as well as the standard for evaluating the value of the built environment after its construction. Recently, accidents, such as fires and breakdowns, in huge and complicated buildings have increased the importance of user behavior simulation. The Korean government has tried to establish a regulation for the prevention of accidents in the built environment. This is regarded as a significant step forward for providing a safer and more appropriate environment for users. However, the existing technologies related to analyzing user behavior only simulate simplified situations. Such simulations are not enough to evaluate accurately the designed alternatives because buildings and spaces contain more complicated information than what we have conventionally considered. Thus, we propose that the advanced agent can interact with the architectural context. It can understand not only the physical situation but also how the users affect this situation. In order to realize this, we adopted the concept of affordances as the perceived action possibilities for the simulation environment.

A study on the Measurement and Improving Method of Indoor Air Quality in a Educational Facility (교육시설물의 실내공기질 측정 및 개선방안에 관한 연구)

  • Kim, Sung-Kyum;Kim, Jae-On;Cho, Chang-Yeon;Kim, Jong-Rok;Son, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.4
    • /
    • pp.43-52
    • /
    • 2007
  • People spend more than 90% of their time indoor. Nowadays as they are interested in environment much more than before, indoor air pollution has been regarded as new environmental problems. At present, an air quality check is required prior to the completion of construction. However this study shows that the density level of HCHO and VOCs in a classroom was increased after furnishing the classroom. Thus, to measure the quality of air more effectively and accurately, it should be measured after the indoor space are furnished. Newly-built schools are tested for this study. The building sites were investigated to measure and evaluate the IAQ (Indoor Air Quality) in newly-built schools. The result of this study can be used as a basis to improve the environment air condition of the educational facilities.

Wind loads on T-shaped and inclined free-standing walls

  • Geurts, Chris;van Bentum, Carine
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.83-94
    • /
    • 2010
  • Wind tunnel measurements on T-shaped free-standing walls and inclined free-standing walls have been carried out. Mean net pressure coefficients have been derived and compared with previous research. It was observed that the high loads at the free ends are differently distributed than those derived from the pressure coefficients for free-standing walls in EN 1991-1-4. In addition net pressure coefficients based on extreme value analysis have been obtained. The lack of correlation of the wind induced pressures at windward and leeward side result in lower values for the net pressure coefficients when based on extreme value analysis. The results of this wind tunnel study have been included in Dutch guidelines for noise barriers.

Investigating risk of overheating for school buildings under extreme hot weather conditions

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.277-287
    • /
    • 2017
  • This study examines the risk of overheating of a school building, under extreme hot weather conditions, in 14 locations in the United Kingdom using the overheating criteria defined in Building Bulletin 101 (BB101). The building was modelled as naturally ventilated, mechanically ventilated and in mixed mode and was simulated both for the current and the projected weather conditions of the 2050s. Under the current weather conditions, results of the simulations show that when naturally ventilated, the school building fulfils the BB101 criteria only in the areas of Edinburgh and Glasgow. In the simulations of the building as mechanically ventilated and in mixed mode, mechanical cooling was provided in order for the building to comply with the overheating criteria. A comparison of the required cooling loads between the two scenarios shows that application of mixed mode ventilation results in less cooling loads.