• 제목/요약/키워드: Buildings

검색결과 10,031건 처리시간 0.03초

Investigation of blast-induced ground vibration effects on rural buildings

  • Oncu, Mehmet Emin;Yon, Burak;Akkoyun, Ozgur;Taskiran, Taha
    • Structural Engineering and Mechanics
    • /
    • 제54권3호
    • /
    • pp.545-560
    • /
    • 2015
  • In this paper, blast-induced vibration effects on buildings located in rural areas were investigated. Damages to reinforced concrete, adobe and masonry buildings were evaluated in Çatakk$\ddot{o}pr\ddot{u}$ and Susuz villages in Silvan district of Diyarbakir, Turkey. Blasting of stiff rocks to construct highway at vicinity of the villages damaged the buildings seriously. The most important reason of the damages is lack of engineering services and improper constructed buildings according to the current building design codes. Also, it is determined that, inappropriate blast method and soft soil class increased the damages to the buildings. The study focuses on four points: Blast effect on buildings, soil conditions in villages, building damages and evaluation of damage reasons according to the current Turkish Earthquake Code (TEC).

내진성능평가시 횡보강근이 없는 RC 보-기둥 접합부의 전단내력 평가 (Seismic Assessment of Shear Capacity of RC Beam-Column Joints Without Transverse Re-bars)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.249-259
    • /
    • 2019
  • To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.

지진파 주기특성에 따른 고층건축물의 응답특성 평가를 위한 동적실험 (Dynamic Experiment to Evaluate Response Characteristics of High-Rise Buildings on Period Characteristics of Seismic Waves)

  • 오상훈;김주찬
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.127-133
    • /
    • 2019
  • Damage to high-rise buildings caused by earthquakes is less frequency due to small distribution of high-rise buildings and low transmissibility of seismic motion to high-rise buildings. However, demand for high-rise buildings is increasing for development of construction technology and efficient land use. In addition, if high-rise buildings are constructed on soft ground such as landfill, transmissibility of seismic motion due to long-periodization of seismic waves is likely to increase. Thus, with development of technology, buildings are required to expand range of seismic design such as safety for long-period seismic waves. Therefore, in this study, dynamic experiments were performed to evaluate response characteristics of high-rise buildings according to period characteristics of seismicwaves and time history analysis was performed to verify them.

일제강점기 수원화성의 관아건축 훼손과정에 관한 연구 (A Study on the Process to Demolish Official Buildings in Suwon during Japanese Colonial Period)

  • 안국진;최지해
    • 건축역사연구
    • /
    • 제29권6호
    • /
    • pp.19-28
    • /
    • 2020
  • This study examines the process to demolish official buildings of Joseon Dynasty in Suwon Hwaseong during Japanese colonial period. King Jeongjo built the new Suwon city and constructed the city fortress. Hwaseong Hawnggung and other official buildings were also built in Suwon Hwaseong. However Those buildings were demolished gradually and lost their identity during Japanese colonial period. The official buildings of Hwaseong Haenggung were classified into nine parts. 1) Central area of Hwaseong Haenggung 2)Nangnamheon(落南軒) 3)Uhwaguan(于華館) 4)Namgunyeong(南軍營) 5)Bukgunyeong(北軍營) 6)Gangmudang(講武堂) 7)Yiah(貳衙) 8)Jungyeong(中營) 9) Hoeryungjun(會寧殿). Bukgunyeong was the first demolished building in Suwon Hwaseong. Nangnamheon and Hwaryungjun were not destroyed during Japanese Colonial Period. from 1910s to 1930s most official buildings were demolished and new buildings were rebuilt.

Research on the Enhancement Trend of the Urbanity of High-rise Buildings

  • Huiqiong Tian;Jiaqi Qu;Zhendong Wang
    • 국제초고층학회논문집
    • /
    • 제12권1호
    • /
    • pp.11-18
    • /
    • 2023
  • The urbanity of high-rise buildings does not simply reference their physical characteristics but also encompasses their impact on the overall urban environment and the daily lives of citizens. This involves the economic benefits, social development, urban culture and public activities that high-rise buildings bring to a city. High-rise buildings are an important aspect of urban development and play a crucial role in providing public services in high-density urban habitats. However, to ensure that their contribution to the city is positive, it is essential to take into account their impact on surrounding buildings and the built environment. This paper analyzes their urban attributes and value system and summarizes their current development status. In short, as the demand for public services continues to evolve, it is necessary for high-rise buildings to keep up with these changes by continuously enhancing their urbanity.

Seismic assessment of R/C residential buildings with infill walls in Turkey

  • Korkmaz, Kasim Armagan;Kayhan, Ali Haydar;Ucar, Taner
    • Computers and Concrete
    • /
    • 제12권5호
    • /
    • pp.681-695
    • /
    • 2013
  • In 1999 Marmara and 2011 Van earthquakes in Turkey, majority of the existing buildings either sustained severe damage or collapsed. These buildings include masonry infill walls in both the interior and exterior R/C frames. The material of the masonry infill is the main variant, ranging from natural stones to bricks and blocks. It is demanding to design these buildings for satisfactory structural behavior. In general, masonry infill walls are considered by its weights not by interaction between walls and frames. In this study, R/C buildings with infill walls are considered in terms of structural behavior. Therefore, 5 and 8-story R/C buildings are regarded as the representative models in the analyses. The R/C representative buildings, both with and without infill walls were analyzed to determine the effects of structural behavior change. The differences in earthquake behavior of these representative buildings were investigated to determine the effects of infill walls leading structural capacity. First, pushover curves of the representative buildings were sketched. Aftermath, time history analyses were carried out to define the displacement demands. Finally, fragility analyses were performed. Throughout the fragility analyses, probabilistic seismic assessment for R/C building structures both with and without infill walls were provided. In this study, besides the deterministic assessment methodology, a probabilistic approach was followed to define structural effect of infill walls under seismic loads.

비선형 동적해석을 이용한 소규모 필로티형 철근콘크리트 건축물의 내진성능평가 (Seismic Performance Evaluation of Small-size Pilloti-type Reinforced Concrete Buildings using Nonlinear Dynamic Analysis)

  • 유창환;김태완;추유림
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.191-199
    • /
    • 2016
  • Piloti-type building is one of typical vertical atypical buildings. These buildings can fail by weak-story or flexible-story mechanism on the first story. They should be designed by taking into account the special seismic load, but those less than six stories are not required to confirm the seismic performance from structural engineers in Korea. For this reason, small-size pilloti-type RC buildings need to be checked for seismic performance. Based on this background, this study performed nonlinear dynamic analysis using the PERFORM-3D for small-size pilloti-type RC buildings and assessed their seismic performance. Examples are two through four story buildings with and without walls in the first story. The walls and columns in the first story satisfied the target performance in the basic of flexural behavior due to quite a large size and reinforcement. However, wall shear demands exceed shear strength in some buildings. When designed for KBC2009, wall shear strength exceed shear demand in some buildings, but still does not in others. Consequently, wall shear must be carefully checked in both existing and new small-size pilloti-type RC buildings.

Surface temperatures of public buildings, built in 1880, 1970 and 2002, in Northern Greece

  • Kosmopoulos, P.;Kantzioura, A.
    • Advances in Energy Research
    • /
    • 제1권1호
    • /
    • pp.79-95
    • /
    • 2013
  • The purpose of this paper is to investigate the surface temperatures of the shelter of three public buildings in the city of Xanthi, in northern Greece. The buildings were built in different time periods and consequently they have different technical characteristics. Respectively, we survey the three following buildings that have been built in 1880 (Municipality Hall of Xanthi), in 1970 (Municipality Amphitheatre) and in 2002 (Bank offices building). Data have been gathered by the use of thermal camera and the survey has been conducted from January up to July. The data gathered regard measurements of the surface temperature of the exterior walls of the shelters, both inside and outside. The study aims at the evaluation of the thermal behavior of the shelter of buildings, which built in different time and under different regulations. The gathered data of the surface temperatures compare the different thermal behavior of the shelter. The analysis of the results and diagrams show that the thick masonry of the traditional Municipality Hall offers an insulation that is adequate. The building of 1970, which was constructed with the previous buildings regulation, has thermal losses due to inadequate insulation. The new building of 2002 has low thermal losses.

학교건축물의 내진현황과 내진성능 특성에 관한 연구 (A Study on the Current State of Seismic-Resistance and the Feature of Seismic Performance in School Buildings)

  • 조민주;이주나
    • 교육시설 논문지
    • /
    • 제19권3호
    • /
    • pp.33-40
    • /
    • 2012
  • At present, the problem to secure seismic resistance capacity is one of the most important issue in school buildings. However, the range of facilities to consider retrofit or the proper direction of seismic retrofit haven't provided in details. Therefore in this study, a series of school buildings were chosen as established time, and the structure composition and the seismic performance of the school buildings were investigated to get the comprehensive features of seismic resistance capacity in school buildings. At result, it was presented that the member capacities were less than criteria and structure system was showed the brittle behavior at the collapse prevention level at the school buildings before 1990 year. At the school buildings after 1990 year, though it is hard to get general features for various compositions, it was presented that they have problems for seismic performance evaluation in some buildings at life safety level, specially in the direction of X axis. So, considering the introduction process of seismic criteria in Korea, the school buildings before 2005 year should be examined for seismic resistance capacity and the seismic performance should be examined as well as member capacity to resist seismic.

공동주택에서의 실내환경의 질 평가에 관한 연구 - 미국 공동주택 사례를 중심으로 - (A Study on Indoor Environmental Quality Evaluation in Apartment Buildings - Focus on Apartment Buildings in USA -)

  • 윤성훈
    • 한국실내디자인학회논문집
    • /
    • 제18권4호
    • /
    • pp.79-87
    • /
    • 2009
  • Residential Buildings should provide high-quality, comfortable environments to support the activities of their occupants. The indoor environment of residential buildings, which includes thermal, lighting, acoustic, and indoor air quality, has a significant impact on health and quality of life. The comfortable living environment in residential buildings result from appropriately combining these environmental quality factors, and the performance of building systems must be compatible with the activities of the occupants. The objective of this research is to investigate and analyze the relationship between physical environmental conditions and occupant responses for improving environmental quality (EQ) in apartment buildings with four different building orientations (i.e. E, W, S, N) in two different seasons (i.e. winter and summer). The occupant survey was conducted in actual apartment buildings. The Physical environmental conditions in apartment buildings differed substantially depending on space, outdoor weather conditions and building orientations. Each space within the same apartment building had different environmental conditions. Combinations of unbalanced physical environmental conditions in apartment building decrease occupants' satisfactions and their perceptions of overall residential quality. Occupants' satisfaction and their responses to physical characteristics of their residential environment is related to thermal, lighting, acoustic, and indoor air conditions in their buildings. The result from this research will help designers and researchers to identify problems and develop solutions for improving environmental quality from the occupants' point of view.