• Title/Summary/Keyword: Building energy simulation program

Search Result 142, Processing Time 0.025 seconds

Thermal Performance Evaluation of Movable Insulation System in Apartments (공동주택 발코니창에 설치된 가동단열 시스템의 열성능 평가)

  • Yoon, Jong-Ho;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.28-35
    • /
    • 2008
  • The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

Selection of Energy Conservation Measures for Building Energy Retrofit: a Comparison between Quasi-steady State and Dynamic Simulations in the Hands of Users

  • Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.5-12
    • /
    • 2016
  • Purpose: Quasi-steady state simulations have played a pivoting role to expand the user group of simulation to design engineers and architects in Korea. Initially they are introduced in the market as a building energy performance rating tool. In domestic practice, however, quasi-steady state simulations seem to be regarded as a de facto simulation only available for energy retrofit. Selection of ECMs and economic feasibility analysis are being decided through these tools, which implies that running these tools has become a norm step of the Investment-grade Audit. Method: This study aims at identifying issues and problems with the current practice via test cases, analyzing the reasons and opportunities, and then eventually suggesting proper uses of quasi-steady state and dynamic simulations. Result: The functionality of quasi-steady state simulations is more optimized to the rating. If they are to used for energy retrofits, their off-the-shelf functions also need to be expanded for customization and detailed reports. Yet their roles may be limited only to the go/no go decision; because their algorithms are still weak at precisely estimating energy and load savings that are required for making investment decisions compared to detailed simulations.

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.

A Study on the Optimum Slope of the Roof for Minimum Cooling Load (냉방부하 최소화를 위한 지붕의 최적기울기에 관한 연구)

  • Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.119-123
    • /
    • 2005
  • The main purpose of this study is to define an optimum slope of the roof that demands minimum cooling load of the building, when the roof is affected by the solar and wind energy. Two different roof shapes were chosen: hip, gabled. The cooling load of building having those roof shapes was calculated through the computer simulation, using DOE program. For the simulation, the angle of the roof and angle of the orientation was changed. In the conclusion of this paper, an optimum slope of the roof which causes minimize cooling load is presented according to the roof shape and orientation. The result of this study could provide a practical design guideline for determining the roof angle for various climatic conditions.

The Analysis of the Energy Saving Performances of Building Materials using Phase Change Materials (상변화물질을 적용한 건축자재의 에너지절약 가능성 분석)

  • An, Sang-Min;Hwang, Suck-Ho;Kim, Tae-Yeon;Leigh, Seung-Bok
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.162-167
    • /
    • 2011
  • Thermal storage plays an important role in building energy saving, which is greatly assisted by the incorporation of latent heat storage in building materials. A phase change material is a substance with a high heat of fusion which, melting and solidifying at a certain temperature, can be storing and releasing large amount of energy. Heat is stored or released when the material changes from solid to liquid. Integration of building materials incorporating PCMs into the building envelope can result in increased efficiency of the built environment. The aim of this research is to identify thermal performance of PCMs impregnated building materials which is applied to interior of building such as gypsum and red clay. In order to analyze thermal performance of phase change materials, test-cell experiments and simulation analysis were carried out. The results show that micro-encapsulated PCM has an effect to maintain a constant indoor temperature using latent heat through the test-cell experiments. PCM wallboard makes it possible to reduce the fluctuation of room temperature and heating and cooling load by using EnergyPlus simulation program. Phase change material can store solar energy directly in buildings. Increasing the heat capacity of a building is capable of improving human comfort by decreasing the frequency of indoor air temperature swings so that the interior air temperature is closer to the desired temperature for a long period of time.

  • PDF

A Study on Prediction Method of Sky Luminance Distributions for CIE Overcast Sky and CIE Clear Sky (CIE 표준 담천공과 청천공 모델의 천공 휘도분포 예측 방법에 관한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.33-43
    • /
    • 2016
  • Daylight is an important factor which influences building energy efficiency and visual comfort for occupants. It is important to predict precise sky luminance at the early stages of design to reduce light energy in the building. This study predicted sky luminance distributions of standard sky model(CIE overcast sky, CIE clear sky) that was provided from the CIE(Commission internationale de $l^{\prime}{\acute{e}}clairage$). Afterward, result of sky luminance was compared and verified with simulation value of Radiance program. From the CIE overcast sky, zenith and horizon ratio is about 3:1. From the CIE clear sky, luminance value gets most high value around the sun. On the other hand, luminance value is the lowest in the opposite direction of the sun when angle is $90^{\circ}$ between the sun and sky element. As a result of comparing the calculation results with Radiance program, sky luminance prediction error rate is 0.4~1.3% when it is CIE overcast sky. Also, sky luminance prediction error rate is 0.3~1.5% when it is CIE clear sky. When compared with the results of radiance simulation, it was evaluated as fairly accurate.

A Comparative study on the Insulation Performance of the Tilt & Sliding System Window by Actual Survey and Simulation (Tilt & Sliding 시스템창호의 단열성능 실측과 시뮬레이션 비교 분석)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.222-226
    • /
    • 2009
  • The parts of building which has the most influence on thermal load are skins, outer walls and windows. Among them, window is the worst weak point of building even if it has many advantage of solar radiation gain than other parts. The present time, many researches on various performance of window and many types of system-window are being made. This study evaluates thermal performance of tilt & sliding system window by simulation program Therm 5.2 and Window 5.2. After making a sample model improving it's thermal weak point, this study evaluates real thermal performance of system window. As a result, this study understands manufacture ability condition of domestic company and proposes a research plan of system window.

  • PDF

Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings (노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교)

  • Lhee, Sang-Choon;Choi, Young-Joon;Kim, Hyun-Ki;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.