• 제목/요약/키워드: Building energy performance

검색결과 1,428건 처리시간 0.03초

Mock-up실험을 통한 BIPV Module의 외벽 성능평가 (A Experimental Study on Finished Envelope Performance of BIPV Module)

  • 이소미;윤철;이용호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.251-256
    • /
    • 2008
  • Nowaday, The Sustainable Development about global environment is the most important subject. In urban environment, a variety of the nature energy utilization such as the solar energy are the most efficient solution to solve this issue. One of these efficient solutions, a photovoltaic system using sunlight has been introduced to the building with an advantage such as cost-effective, safe for using and good for environment friendly in light with energy utilization. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. Therefore the goal of this study is to get securing the application information of BIPV as finished envelope. The purpose of this study is to investigate the current performance measurement methods of BIPV module and to measure the performance of BIPV module by mock-up tests.

  • PDF

단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능 (Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards)

  • 김세종;박주생
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.876-883
    • /
    • 2015
  • 국립산림과학원에서는 한옥의 전통건축기술을 바탕으로 한국형 기둥-보 목조주택인 ?그린 프로젝트를 2006년부터 진행해오고 있다. 최근에는 에너지 절약 기술요소를 적용하여 건물의 에너지성능을 개선하고자 하였다. 본 연구에서는 강화된 단열기준에 따른 기둥-보 목조벽체의 단열상세를 제시하고 그에 따른 건물 에너지 절감 효과를 평가하고자 하였다. 건물외피의 열관류율은 현행법 수준과 저에너지주택인 패시브하우스 수준인 두 단계로 나누었으며 건물에너지 성능을 평가하기 위하여 건물의 기밀성능은 국내 신축 목조주택 수준인 $3.0h^{-1}$과 패시브하우스 수준이 $0.6h^{-1}$ 두 단계로 나누어 열관류율과 기밀성능의 조합에 따라 4가지 경우에 대한 건물에너지 성능 평가가 이루어졌다. 대상건물은 서울에 위치하였으며 에너지 성능은 상용 건물에너지성능 평가 프로그램인 CE3가 사용되었다. 강화된 열관류율에 따라 시뮬레이션을 진행한 결과 연간 난방에너지 요구량은 $14kWh/(m^2{\cdot}a)$ 절감효과를 나타냈다.

실시간 빌딩 시뮬레이션을 위한 예측 기상 기반의 기상 데이터 파일 작성 기법 (Forecasted Weather based Weather Data File Generation Techniques for Real-time Building Simulation)

  • 곽영훈;정용우;한혜심;장철용;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.8-18
    • /
    • 2014
  • Building simulation is used in a variety of sectors. In its early years, building simulation was mainly used in the design phase of a building for basic functions. Recently, however, it has become increasingly important during the operating phase, for commissioning and facility management. Most building simulation tools are used to estimate the thermal environment and energy consumption performance, and hence, they require the inputting of hourly weather data. A building simulation used for prediction should take into account the use of standard weather data. Weather data, which is used as input for a building simulation, plays a crucial role in the prediction performance, and hence, the selection of appropriate weather data is considered highly important. The present study proposed a technique for generating real-time weather data files, as opposed to the standard weather data files, which are required for running the building simulation. The forecasted weather elements provided by the Korea Meteorological Administration (KMA), the elements produced by the calculations, those utilizing the built-in functions of Energy Plus, and those that use standard values are combined for hourly input. The real-time weather data files generated using the technique proposed in the present study have been validated to compare with measured data and simulated data via EnergyPlus. The results of the present study are expected to increase the prediction accuracy of building control simulation results in the future.

기존 노후 건물의 단열 성능에 따른 옥상 녹화 시스템 설치시 에너지 성능 변화 (Energy Saving Effects of Green Roof in Exiting Buildings according to Different Insulation Levels)

  • 안경아;한승원;문현준
    • 한국생활환경학회지
    • /
    • 제21권6호
    • /
    • pp.959-964
    • /
    • 2014
  • Energy performance of building envelope components, including external walls, floors, roofs, windows and doors, is crutial for determining how much energy is required for heating and cooling in a building. Among various building technologies, a green roof system can be a good option for reducing heat gain and loss in new buildings as well as existing buildings for green remodeling. This paper evaluates the performance of green roof systems according to soil depth and Leaf Area Index (LAI) for existing buildings. It also attempts to quantify the energy saving effects on new and existing buildings with different insulation levels. Thermal performance of green roofs is mainly dependent on soil thickness and LAI. Installation of green roofs in deteriorated existing buildings can lead to improvements in roof insulation, due to the soil layer. An increase in soil depth leads to a decrease in heating load, regardless of conditions of vegetation on the green roof. Larger LAI values may reduce cooling loads in the cooling season. Installation of green roof in deteriorated existing buildings showed bigger energy saving effect in comparison to a case in new buildings. A simulation study showed that the installation of green roof systems in deteriorated existing buildings with low insulation levels, due to low thermal performance requirements when constructed, could improve the energy performance of the buildings similar or better to the peformance on new buildings with the most updated insulation standard. Thus, when remodeling a deteriorated building, green roofs could be a good option to meet the most recent energy requirements.

회귀분석에 의한 건물에너지 사용량 예측기법에 관한 연구 (A Study for Predicting Building Energy Use with Regression Analysis)

  • 이승복
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1090-1097
    • /
    • 2000
  • Predicting building energy use can be useful to evaluate its energy performance. This study proposed empirical approach for predicting building energy use with regression analysis. For the empirical analysis, simple regression models were developed based on the historical energy consumption data as a function of daily outside temperature, the predicting equations were derived for different operational modes and day types, then the equations were applied for predicting energy use in a building. BY selecting a real building as a case study, the feasibilities of the empirical approach for predicting building energy use were examined. The results showed that empirical approach with regression analysis was fairly reliable by demonstrating prediction accuracy of $pm10%$ compared with the actual energy consumption data. It was also verified that the prediction by regression models could be simple and fairly accurate. Thus, it is anticipated that the empirical approach will be useful and reliable tool for many purposes: retrofit savings analysis by estimating energy usage in an existing building or the diagnosis of the building operational problems with real time analysis.

  • PDF

표준부하모델을 이용한 설계 변수에 따른 표준부하량 분석 (A Study on Standard Heating and Cooling Load according to Design Factors using Prototypical Load Model)

  • 김권예;배상무;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권1호
    • /
    • pp.1-13
    • /
    • 2021
  • Before newly-built building and building remodeling, it is important to predict and analyze building energy performance through energy simulation programs. Nevertheless, simulation results widely vary depending on individual user experience and input values. Therefore, this study uses prototypical building model, a versatile tool in building energy modeling, simulation and research for researchers and policy-makers, and ASHRAE standards. Then, it analyzed the changes in design type (roof type, number of floors) for the base case. As the result, it was found that the gap of annual energy demand per between them is maximally 9.1%.

BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석 (A study on the performance of various BIPV modules applied in a real building demonstration)

  • 이상문;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.53-63
    • /
    • 2016
  • Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of $45^{\circ}$ is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.

System Performance with Variation of Outdoor Unit Layouts at Building Re-entrants

  • Koh, Jae-Yoon;Lee, Hyun-Gu;Zhai, John
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권1호
    • /
    • pp.15-21
    • /
    • 2008
  • Air-cooled split-type air conditioners (AC) are very popular in high-rise residential and commercial buildings in Korea. The performance of such AC systems varies significantly with system characteristics and environmental conditions. Particularly, the outdoor condensing unit of the system, if poorly cooled due to high density of AC distribution and restricted outdoor space, will result in large decrease of cooling efficiency and increase of electrical energy consumption and may further jeopardize the system reliability. This paper presents a numerical analysis on the thermal and energy performance of a group of air-cooled air conditioners installed at a courtyard of a high-rise building. The study introduces a series of new energy performance indices to assess the group performance of the AC condensers with different outdoor unit layouts. The results not only indicate the COP of the systems, but also quantify the system capacity and energy consumption. The evaluation method and indices developed are useful for guiding the design of the distribution plan of the AC units at building re-entrants.

발코니 설치식 가동형 차양겸용 BIPV 디자인과 성능연구 (Movable BIPV Shading Device Design for Apartment Building Balcony)

  • 진경일;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.85-92
    • /
    • 2010
  • At the beginning the 21st century, we are interested in renewable energy especially photovoltaic. So, we have been installed PV at the building roofs so that we call it building integrated photovoltaic. But strictly speaking, installing the PV on the roof is not building integrated. There are few BIPV designs especially for balcony. In the apartment building, roof is good installing place for PV, but its area was limited. Now a day, built apartment building's heights are more and more increased so that the performance of installed PV on the roof cannot be enough to use even the public use. Thereby, we need the new space in the building to install the PV except the building roof. This study suggests the building facade balcony as a new space to install the PV with building integrated PV design. Hence, in this study, we are designed the movable BIPV shading device for apartment building balcony, and verified its performance with computer simulation. Developed device in this study can works as an electronic generation device and an overhang on the side balcony. As a result, the electronic generation performance of device contributes 15~30% to each apartment unit. The more unit width increase, the better contributed device generates.

고유가시대에 대비한 건축물의 에너지효율화관련 시책 현황 (The Building Energy Efficient Policy to Tackle Rising High Oil Prices in Korea)

  • 정영선;최경석;김경우;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.959-964
    • /
    • 2006
  • Recently, an international oil price shows fluctuation in 70 dollars per barrel and it is said that this trend is able to continues for much longer. Because energy consumption in buildings accounted for about 25% of the nation's total demand for energy, Energy censervation and efficiency of buildings were very important issues. Main political measures relating to building energy use and saving were 'the system of accrediting green building', 'building energy certification system', 'energy consumption efficiency rating indication system', 'building energy code', 'high efficient energy materials certification system'. This paper presents approaches to improve building energy efficiency policy.

  • PDF