• Title/Summary/Keyword: Building energy performance

Search Result 1,428, Processing Time 0.028 seconds

Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System (주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구)

  • Kang, Eun-Chul;Min, Kyoung-Chon;Lee, Kwang-Seob;Lee, Euy-Joon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2016
  • Heat pump unit performance is represented by the COP(Coefficient of Performance) and expressed by the one point design condition according to KS C 9306. However, when heat pump operated to the real buildings, the simulations are changed continuously according to the actual weather conditions, the building load and heat pump source conditions. The purpose of this paper is to evaluate the APF(Annual performance factor) for a climate dependent building integrated air-to-air heat pump system in major cities in Korea. TRNSYS simulation tool with an international MV standard based IPMVP 4.4.2 was utilized to perform the annual performance analysis. The APF with the multi-performance data based method was calculated as 2.29 for Daejeon residential building case while Busan residential building case appeared as the highest with 2.36.

Comparison Analysis of Building's Heating Energy Consumption in the Apartment Complex - Focused on Apartment in Daejeon - (공동주택 단지 내 동별 난방에너지소요량 비교 분석 - 대전지역 아파트단지를 중심으로 -)

  • Jang, Young-Hye;Kim, Jeong-Gook;Kim, Jonghun;Jeong, Hakgeun;Hong, Won-Hwa;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.37-42
    • /
    • 2015
  • Purpose: Apartment is a typical residential type in Korea. In the past, apartment types were very monotonous. But today, the types of complex are changed because personal needs have been diversified and personalized. In order to meet those needs, construction companies are constructing various types of apartments. The more apartment types are diverse, the more the energy problems are taken place. So, the purpose of this study is to solve the problem of energy gap in the same complex through improving the thermal transmittance of wall. Method: Heating energy consumption of Building Energy Efficiency Rating System and heating energy usage of apartment show a similar trend on the graph. In order to identify the best position of heating energy consumption difference reduction, we change the building's U-value of front, back, side walls. Result: In the A complex, maximum and minimum heating energy consumption building's shapes are flat. the best efficiency is side U-value change and the worst is front change. In the E complex, maximum heating energy consumption building's shape is tower and minimum building shape is flat. Consequently, the front and back wall performance change was little effect to reduce energy gap, while the change of side wall's U-value show the great reduction between building's energy consumptions.

The Feasibility Analysis of Organic Waste Bioenergy System in Apartment Complex (유기성 폐자원 바이오에너지 시스템의 공동주택 적용 타당성 평가에 관한 연구)

  • Ko, Myeong-Jin;Choi, Mi-Young;Choi, Doo-Sung;Kim, Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.474-481
    • /
    • 2010
  • Because international environmental and energy problems such as global warming and ozone depletion, exhausting of fossil energy sources are more serious than before, renewable energy system is attracting people's attention more and more. Organic waste bioenergy system among a variety of renewable energy system is expected to have an effect on building a society which is eco-friendly and recycles resources owing to carbon neutral effects. So this is considered as the role of an energy source of the building. Previous studies on the organic waste bioenergy are mainly bioenergy technology and activation plan of the bioenergy supply. But the performance evaluation studies of bioenergy systems installed in buildings are rarely. This study is to evaluate applicability of the organic waste bioenergy system as the building energy supply system by energy and environmental, economical analysis.

Performance Assessment of Building Envelopes I: Double Skin Facade (외피 친환경 성능평가 I: 이중외피)

  • Kim, Deuk-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.77-82
    • /
    • 2009
  • Many countries have been interested in sustainable development of buildings for environmental preservation. Thus it is significant to assess building envelopes in terms of $CO_2$ emissions owing to Kyoto Protocol. In this paper, a Double Skin Facade(DSF) installed in a general office building was assessed by $CO_2$ emissions(one of the performance-based assessment). To predict $CO_2$ emissions caused by the building energy consumption, the dynamic simulation program(Energy Plus) and $CO_2$ emission factor was used. Because DSF has various airflow regimes, pre-simulation runs were conducted to decide proximate optimal airflow regimes depending on seasonal variation. It is shown that the DSF can achieve 17.1-36.5% of annual energy savings.

  • PDF

Analysis of the Thermal Environment and Natural Ventilation for the Energy Performance Evaluation of the Double Skin System during the Summer (이중외피 시스템의 에너지성능평가를 위한 하절기 열환경 및 자연환기 분석)

  • Eom, Jung-Won;Cho, Soo;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.68-76
    • /
    • 2002
  • This paper discusses thermal and ventilation performance which might be caused by the adoption of one of specific building facade techniques, Double Skin System(DSS). One building with a prototypical DSS was selected and systematically investigated through field monitoring and computer simulation techniques. A network model of ventilation was successfully made using COMIS to evaluate ventilation performance of the system which can hardly be done by field measurements. Various operating conditions of air conditioning on/off and window opening were implemented in this type of building. Through the appropriate operation of the DSS in summer, simulation-based and experimental results implicate that it can lead to cooling energy savings.

A study on analysis of energy consumption of Detached house by U-value and SCs of windows and Building Orientation (창의 종류 및 차폐계수 변화와 건물 향에 따른 단독주택의 에너지요구량 분석)

  • Jeong, Su-Hui;Park, Hyo-Sun;Lee, Byung-Yun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • Annual energy consumption in detached houses are affected mainly by thermal performance of envelope. In particular the performance of glasses are critical due to global wanning and climatic change. Therefore, this research analyzes annual consumption of cooling and heating energy with various combination of U-value, shading coefficient and building orientation. The simulation results shows that shading coefficient of glazing contributes to the changes of proportion of heating and cooling energy demand and the optimized shading coefficient for minimizing energy consumption varies with buildings orientation.

A Study on the Space Boundary Information Interoperability Improvement of IFC Data for Building Energy Performance Assessment (IFC 데이터의 건물에너지 성능평가를 위한 공간경계정보 호환성 향상 연구)

  • Choi, Jungsik;Kim, Inhan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.129-137
    • /
    • 2014
  • Due to the increase of carbon dioxide and building regulations, BIM is considered a way of low-carbon and eco-friendly building development for its many advantages. The advantages can be maximized with Open BIM since it can produce optimal results for various purposes of energy performance assessment. However there are some problems in data interoperability in the process of Open-BIM based energy performance assessment. To solve such problems, this study focuses on space boundary information interoperability between IFC of Open BIM and IDF format of Energy Plus known as the most accurate and diverse energy performance assessment. The study analyzes the analogous study then figures out the problems of IFC based energy performance analysis, and suggests the way of interoperability. Finally, the development of automation program makes this way much more effective. The study of IFC data interoperability is useful for improving the reliability of Open-BIM based energy assessment.

Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster (재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가)

  • Park, Beungyong;Cho, Jinkyun;Jeong, Yongdae;Lee, Wonhak
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

Public Building Value Evaluation Using Contingent Valuation Method Based on Market Value Estimation

  • PARK, Jieun;YU, Jungho
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.367-370
    • /
    • 2015
  • Building deterioration reflects the degradation of basic building performance including structural performance, energy performance, durability, and safety, and it also includes perceived deterioration, which considers a user-based perspective. More than 50% of the existing buildings in Korea are over 15 years old and public buildings compose 2.5% of all buildings domestically. Therefore, there are several different problems, such as poor energy efficiency, structural performance, and safety. To address the challenges of increasing stock in deteriorated buildings, it is necessary to make decisions about reconstruction or renovation. In this study, we propose a new method to evaluate public building value with a contingent valuation method (CVM). By estimating willing-to-pay (WTP) from users of private buildings in similar situation with the public building, it is possible to compare market prices and calculate a correction factor to adjust the WTP data. Finally, we apply the correction factor to the WTP of a public building and estimate market price, willingness to pay (WTP). Finally, we apply the correction factor to willing to pay (WTP) of public building and estimate market price.

  • PDF

Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building (업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측)

  • Sohn, Byonghu;Kwon, Han Sol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.