• Title/Summary/Keyword: Building damages

Search Result 354, Processing Time 0.022 seconds

Preliminary Study on the Enhancement of Seismic Performance of Korea Hospital Buildings (우리나라 병원건축물의 내진성능향상을 위한 기초연구)

  • Kim, Namhee;Hong, Sung-Gul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.509-516
    • /
    • 2016
  • Secure operation of hospitals during and right after earthquake is essential. Past lessons from earthquake damages have shown that most of the injured and the death occurred within 30 minutes after earthquake and the portion of nonstructural damage has become significant. However, hospital buildings in Korea have not prepared fully to address such rising issues. This paper is to study what type of damage patterns are related to hospital buildings and how to develop a preparedness plan to keep hospitals operational at all earthquakes if possible. This paper first reviews on past earthquake damages reported as critical to hospital buildings while classifying them into four groups: (1) structural element; (2) architectural-nostructural element; (3) medical equipments and contents; and (4) utility facility. Upon such classification, some detailed concerns can be specified under each group explicitly. Then a hierarchy for hospital building is also developed for the classified groups, which enables us to identify required things for the enhancement of seismic performance of hospital building that consists of heterogeneous elements. To upgrade the level of seismic performance for existing hospital buildings, the concept of performance-based approach can be adopted to address the heterogeneous problems in a systematic and stepwise manner. Finally a conceptual framework for the seismic risk assessment for hospital building is proposed toward the seismic enhancement of hospital buildings using performance-based approach.

Wind pressure characteristics of a low-rise building with various openings on a roof corner

  • Wang, Yunjie;Li, Q.S.
    • Wind and Structures
    • /
    • v.21 no.1
    • /
    • pp.1-23
    • /
    • 2015
  • Wind tunnel testing of a low-rise building with openings (holes) of different sizes and shapes on a roof corner is conducted to measure the internal and external pressures from the building model. Detailed analysis of the testing data is carried out to investigate the characteristics of the internal and external pressures of the building with different openings' configurations. Superimposition of the internal and external pressures makes the emergence of positive net pressures on the roof. The internal pressures demonstrate an overall uniform distribution. The probability density function (PDF) of the internal pressures is close to the Gaussian distribution. Compared with the PDF of the external pressures, the non-Gaussian characteristics of the net pressures weakened. The internal pressures exhibit strong correlation in frequency domain. There appear two humps in the spectra of the internal pressures, which correspond to the Helmholtz frequency and vortex shedding frequency, respectively. But, the peak for the vortex shedding frequency is offset for the net pressures. Furthermore, the internal pressure characteristics indirectly reflect that the length of the front edge enhances the development of the conical vortices.The objective of this study aims to further understanding of the characteristics of internal, external and net pressures for low-rise buildings in an effort to reduce wind damages to residential buildings.

Assumption and Climate-Map Drawing of Ultra Violet Rays Influencing to the Deterioration of Building Exterior Materials (건축물 외장재 열화현상에 영향을 미치는 자외선 발생량 추정 및 기후 맵 작성)

  • Yee, Jurng-Jae
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.19-26
    • /
    • 2006
  • Recently, building requirements have been saturated and residents are demanding a variety of building exterior materials faced with roofs, walls, windows and doors. On the other hand, when building exterior materials are exposed with ultra violet rays during some periods, these will be influenced deterioration effects like discolorations, exfoliations and cracks and will be needed exchange of materials. In this study, main 17-provinces of Korea were collated climate data and counted the computation results with an assumption formula for calculating ultra violet rays amounts. Lastly, ultra violet rays map of Korea was made by the counted data and was considered tendencies. Accordingly, in the phase of design the designer can select the appropriate exterior materials which have durabilities and resistances of ultra violet rays. So hereafter this study can be a foundation study to sustain building exterior materials with ultra violet rays damages. Below is the summary of Korean ultra violet rays tendency. 1. Ultra violet rays during 1 year is from about $180MJ/m^2$ to about $210MJ/m^2$. 2. Southern province ultra violet rays is higher than northern province. 3. Annually counted rays is higher and higher.

An Evaluation of Fire Resistance and Mock-up Test of the Alumino-silicate Fire Resistant Board (알루미노 실리케이트계 내화보드의 내화성능 및 현장적용성 평가)

  • Kim, Doo-Ho;Park, Dong-Cheol;Kim, Woo-Jae;Lee, Sea-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.43-47
    • /
    • 2010
  • The use of high-strength concrete has increased for its excellent structural stability as buildings become higher and bigger than ever before in Korea and overseas recently. The functional requirement of building materials has also been bolstered so for the high -performance, high-quality construction materials to be used more extensively. However, the internal structure of the high-strength concrete is very dense so spalling can be caused during fire. The spalling in turn can cause critical structural damages followed by the fatal consequences, demolition of the building. Therefore, ensuring fire safety for high-rise buildings is assumed to be urgent. Alumino-silicate fire resistant board producing technology has been developed in situations that new materials with excellent fire resistance and easy installation has been sought. The alumino-silicate fire resistant board turned out to exhibit not only fire resistance and excellent physical and dynamical characteristics but also excellent onsite applicability and easy process and transportation after completing Mock-up test. Its excellence as a high-performance building materials was proven.

  • PDF

Necessity of Korean Integrated Life Safety Code and Fire Safety Performance Evaluation Technology (한국형 통합 인명안전코드 및 화재안전 성능평가기술의 필요성)

  • Kwon, Young-Jin;Koo, In-Hyuk;Jin, Seung-hyeon;Lee, Byeong-Heun;Kim, Yun-Seong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, construction projects are gradually becoming high-rise and large-scale, and furthermore, the use of new buildings is emerging through the deepening of the underground. In this situation, a lot of fire damage has occurred in recent years, mainly in buildings and tunnel structures. In particular, damages caused by fires during large-scale construction projects such as freezing warehouse accidents are increasing. In this situation, in Korea, it is still trying to secure safety from human fire through the administrative system divided into the building law and the fire law, but it is being developed in a negative direction rather than a positive direction. The fire risk is getting bigger even when the road is not maintained. In this current situation, it is considered that the development of a Korean integrated life safety code centering on the consciousness base of Koreans will be necessary, and in particular, the ease of revision will also be needed by promoting the integrated safety code rather than current laws and regulations. This is a summary of the future tasks.

  • PDF

Development of a disaster index for quantifying damages to wastewater treatment systems by natural disasters (하수처리시설의 자연 재해 영향 정량화 지수 개발 연구)

  • Park, Jungsu;Park, Jae-Hyeoung;Choi, June-Seok;Heo, Tae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.1
    • /
    • pp.53-61
    • /
    • 2021
  • The quantified analysis of damages to wastewater treatment plants by natural disasters is essential to maintain the stability of wastewater treatment systems. However, studies on the quantified analysis of natural disaster effects on wastewater treatment systems are very rare. In this study, a total disaster index (DI) was developed to quantify the various damages to wastewater treatment systems from natural disasters using two statistical methods (i.e., AHP: analytic hierarchy process and PCA: principal component analysis). Typhoons, heavy rain, and earthquakes are considered as three major natural disasters for the development of the DI. A total of 15 input variables from public open-source data (e.g., statistical yearbook of wastewater treatment system, meteorological data and financial status in local governments) were used for the development of a DI for 199 wastewater treatment plants in Korea. The total DI was calculated from the weighted sum of the disaster indices of the three natural disasters (i.e., TI for typhoon, RI for heavy rain, and EI for earthquake). The three disaster indices of each natural disaster were determined from four components, such as possibility of occurrence and expected damages. The relative weights of the four components to calculate the disaster indices (TI, RI and EI) for each of the three natural disasters were also determined from AHP. PCA was used to determine the relative weights of the input variables to calculate the four components. The relative weights of TI, RI and EI to calculate total DI were determined as 0.547, 0.306, and 0.147 respectively.

Development of Decision Support System for Flood Forecasting and Warning in Urban Stream (도시하천의 홍수예·경보를 위한 의사결정지원시스템 개발)

  • Yi, Jaeeung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.743-750
    • /
    • 2008
  • Due to unusual climate change and global warming, drought and flood happen frequently not only in Korea but also in all over the world. It leads to the serious damages and injuries in urban areas as well as rural areas. Since the concentration time is short and the flood flows increase urgently in urban stream basin, the chances of damages become large once heavy storm occurs. A decision support system for flood forecasting and warning in urban stream is developed as an alternative to alleviate the damages from heavy storm. It consists of model base management system based on ANFIS (Adaptive Neuro Fuzzy Inference System), database management system with real time data building capability and user friendly dialog generation and management system. Applying the system to the Tanceon river basin, it can forecast and warn the stream flows from the heavy storm in real time and alleviate the damages.

Implications of the effects of gravity load for earthquake resistant design of multistory building structurtes (고층건물의 내진설계에 미치는 중력하중의 영향)

  • 이동근;이석용
    • Computational Structural Engineering
    • /
    • v.6 no.3
    • /
    • pp.67-80
    • /
    • 1993
  • This paper presents the results of an analytical study to evaluate the inelastic seismic response characteristics of multistory building structures, the effects of gravity load on the seismic responses and its implications on the earthquake resistant design. Static analyses for incremental lateral force and nonlinear dynamic analyses for earthquake motions were performed to evaluate the seismic response of example multistory building structures. Most of considerations are placed on the distribution of inelastic responses over the height of the structure. When an earthquake occurs, bending moment demand is increased considerably from the top to the bottom of multistory structures, so that differences between bending moment demands and supplies are greater in lower floos of multistory structures. As a result, for building structures designed by the current earthquake resistant design procedure, inelastic deformations for earthquake ground motions do not distribute uniformly over the height of structures and those are induced mainly in bottom floors. In addition, gravity load considerded in design procedure tends to cause much larger damages in lower floors. From the point of view of seismic responses, gravity load affects the initial yield time of griders in earlier stage of strong earthquakes and results in different inelastic responses among the plastic hinges that form in the girders of a same floor. However, gravity load moments at beam ends are gradually reduced and finally fully relaxed after a structure experiences some inelastic excursions as a ground motion is getting stronger. Reduction of gravity load moment results in much increased structural damages in lower floors building structures. The implications of the effects of gravity load for seismic design of multistory building structures are to reduce the contributions of gravity load and to increased those of seismic load in determination of flexual strength for girders and columns.

  • PDF

Interference Effects of Change in Wind Passage of a Building Group on Wind Loads and Wind Environments (건축물군의 바람길변화로 인한 풍하중 상호간섭 및 풍환경)

  • Cho, Kang-Pyo;Hong, Sung-Il;Kim, Mu-Hwan;Lee, Ok-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.402-409
    • /
    • 2008
  • Wind loads and environments in realistic situations surrounded by neighboring buildings may be considerably different from those in idealized or simplified situations such as codes and standards. Interference effects of change in wind passage of a building group on wind loads and wind environments are reviewed. Wind-induced interference effects depend mainly on the building geometry and arrangement of these structures, their orientation and upstream terrain conditions. The most important factor among them may be the arrangement of building structures which can change the wind direction directly. Interference effects regarding wind loads are discussed with examples of window damages by typhoon and of pressure measurements in the boundary layer wind tunnel. Wind environment problems are also discussed, specially underlined on pedestrian comfort and safety. Various evaluation techniques or standards of wind environment are introduced. The change of wind velocity between the panel-type apartment buildings is examined, depending on the distance each other.

  • PDF

Hurricane vulnerability model for mid/high-rise residential buildings

  • Pita, Gonzalo L.;Pinelli, Jean-Paul;Gurley, Kurt;Weekes, Johann;Cocke, Steve;Hamid, Shahid
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.449-464
    • /
    • 2016
  • Catastrophe models appraise the natural risk of the built-infrastructure simulating the interaction of its exposure and vulnerability with a hazard. Because of unique configurations and reduced number, mid/high-rise buildings present singular challenges to the assessment of their damage vulnerability. This paper presents a novel approach to estimate the vulnerability of mid/high-rise buildings (MHB) which is used in the Florida Public Hurricane Loss Model, a catastrophe model developed for the state of Florida. The MHB vulnerability approach considers the wind pressure hazard exerted over the building's height as well as accompanying rain. The approach assesses separately the damages caused by wind, debris impact, and water intrusion on building models discretized into typical apartment units. Hurricane-induced water intrusion is predicted combining the estimates of impinging rain with breach and pre-existing building defect size estimates. Damage is aggregated apartment-by-apartment and story-by-story, and accounts for vertical water propagation. The approach enables the vulnerability modeling of regular and complex building geometries in the Florida exposure and elsewhere.