• 제목/요약/키워드: Building damages

검색결과 352건 처리시간 0.023초

Observational failure analysis of precast buildings after the 2012 Emilia earthquakes

  • Minghini, Fabio;Ongaretto, Elena;Ligabue, Veronica;Savoia, Marco;Tullini, Nerio
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.327-346
    • /
    • 2016
  • The 2012 Emilia (Italy) earthquakes struck a highly industrialized area including several thousands of industrial prefabricated buildings. Due to the lack of specific design and detailing for earthquake resistance, precast reinforced concrete (RC) buildings suffered from severe damages and even partial or total collapses in many cases. The present study reports a data inventory of damages from field survey on prefabricated buildings. The damage database concerns more than 1400 buildings (about 30% of the total precast building stock in the struck region). Making use of the available shakemaps of the two mainshocks, damage distributions were related with distance from the nearest epicentre and corresponding Pseudo-Spectral Acceleration for a period of 1 second (PSA at 1 s) or Peak Ground Acceleration (PGA). It was found that about 90% of the severely damaged to collapsed buildings included into the database stay within 16 km from the epicentre and experienced a PSA larger than 0.12 g. Moreover, 90% of slightly to moderately damaged buildings are located at less than 25 km from the epicentre and were affected by a PSA larger than 0.06 g. Nevertheless, the undamaged buildings examined are almost uniformly distributed over the struck region and 10% of them suffered a PSA not lower than 0.19g. The damage distributions in terms of the maximum experienced PGA show a sudden increase for $PGA{\geq}0.28g$. In this PGA interval, 442 buildings were collected in the database; 55% of them suffered severe damages up to collapse, 32% reported slight to moderate damages, whereas the remaining 13% resulted undamaged.

교량공사 제3자 피해 손실에 의한 리스크 분석 연구 (A Study on Bridge Construction Risk Analysis for Third-Party Damage)

  • 안성진;남경용
    • 한국건축시공학회지
    • /
    • 제20권2호
    • /
    • pp.137-145
    • /
    • 2020
  • 최근 교량은 장대화, 신공법의 도입에 따른 위험요인의 증가로 교량공사에서의 철저한 안전 및 리스크 관리 체계가 필요하다. 공사 현장 주변에 있는 발주자 건설공사 관련자 및 공사와 관련이 없는 제 3자의 기존 재산에 손해를 발생시킬 수 있어 제3자 피해 손실로 인한 리스크가 명확히 분석되어야 함에도 불구하고 연구가 미비한 실정이다. 본 연구는 교량건설 사업에 대한 국내 주요 보험사의 과거 보험료 지급 실적을 토대로 실제 교량 건설에서 제3자 피해 손실로 인한 손실에 대한 교량건설 특성에 따른 리스크 요인을 분석하고, 정량화된 예측 손실 모델을 개발하고자 하였다. 정량적 교량건설 손실모형 개발을 위해 사고 건당 보험지급액을 총공사비로 나눈 손실비율을 종속변수로 선정하였고, 상부구조, 하부구조, 홍수 및 도급순위가 교량건설 중 제3자 피해에 의한 손실비율에 영향을 미치는 지표로 나타났다. 도출된 결과는 건설프로젝트에 대한 손실 평가 모델 개발에 기존의 프로젝트 내부에서 발생한 손실과 더불어 제3자 피해손실을 고려함으로써 더불어 균형 있는 리스크 평가에 필수적인 지침으로 활용할 수 있다.

Enhanced remote-sensing scale for wind damage assessment

  • Luo, Jianjun;Liang, Daan;Kafali, Cagdas;Li, Ruilong;Brown, Tanya M.
    • Wind and Structures
    • /
    • 제19권3호
    • /
    • pp.321-337
    • /
    • 2014
  • This study has developed an Enhanced Remote-Sensing (ERS) scale to improve the accuracy and efficiency of using remote-sensing images of residential building to predict their damage conditions. The new scale, by incorporating multiple damage states observable on remote-sensing imagery, substantially reduces measurement errors and increases the amount of information retained. A ground damage survey was conducted six days after the Joplin EF 5 tornado in 2011. A total of 1,400 one- and two-family residences (FR12) were selected and their damage states were evaluated based on Degree of Damage (DOD) in the Enhanced Fujita (EF) scale. A subsequent remote-sensing survey was performed to rate damages with the ERS scale using high-resolution aerial imagery. Results from Ordinary Least Square regression indicate that ERS-derived damage states could reliably predict the ground level damage with 94% of variance in DOD explained by ERS. The superior performance is mainly because ERS extracts more information. The regression model developed can be used for future rapid assessment of tornado damages. In addition, this study provides strong empirical evidence for the effectiveness of the ERS scale and remote-sensing technology for assessment of damages from tornadoes and other wind events.

해인사의 흰개미 모니터링 및 방제 방안 (Monitoring of Termite in Haeinsa Temple and Control method)

  • 정소영;이규식;정용재
    • 보존과학연구
    • /
    • 통권23호
    • /
    • pp.77-93
    • /
    • 2002
  • There are several methods of pest control for the prevention of wooden cultural properties from damages caused by insects, especially termites. Those are as follows; physical control, chemical control, biological control, and integrated pest management. In Korea, we primarily use mvestigation of monitoring, fumigation, treatment of insecticidal and antiseptic chemicals, soil termiticide treatment, and termite colony elimination system. As damages by termites were detected at Eunghyanggak and Saundang of Haeinsa temple in June, 1998, we carried out monitoring with wooden device, in order to investigate damages of wooden building by termite and paths of termite invasion. According to the result of investigation of monitoring from1999 to 2002, we found that termites were inhabiting continually at forests around Haeinsa and that wooden buildings such as Saundang, Cheonghwadang were damaged by termites. So we thought that control methods such as soil termiticide treatment and termite colony elimination system would be effective. Especially, to investigate efficacy of termite colony elimination system, we carried out efficacy test of termite colony elimination system in Jongmyo during 17 months(2000.7.~2001.11.). The result of efficacy test showed that termite colony elimination system eliminated termite colonies gradually(over 12 months from installation of colony elimination system to elimination of termite colony).

  • PDF

Seismic assessment of a R/C strategic existing building

  • Mehani, Youcef;Kibboua, Abderrahmane
    • Structural Engineering and Mechanics
    • /
    • 제26권6호
    • /
    • pp.617-634
    • /
    • 2007
  • Algeria is a country with a high seismic activity. During the last decade, many destructive earthquakes occurred, particularly in the northern part, causing enormous losses in human lives, buildings and equipments. In order to reduce this risk in the capital and avoid serious damages to the strategic existing buildings, the government decided to invest into seismic upgrade, strengthening and retrofitting of these buildings. In doing so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed on the basis of site investigation (inspection of the building, collecting data, materials, general conditions of the building, etc), and existing drawings (architectural plans, structural design, etc). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper will provide insight to the vulnerability assessment and strengthening of the telecommunication centre, according to the new code RPA 99/version 2003. Both, static equivalent method and non linear dynamic analysis are performed in this study.

비래염분 전송 및 RC조 구조물 부착과정에 관한 분석 모델링 제안 (A Proposal of Analysis Modeling on the Transfer and Adhesion of Incoming Salt to RC Structure)

  • 조규환;김우재;안재철;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2012
  • RC structure which is located at shoreline has more serious damages compared with inland structure, because it is directly exposed to chlorine ion which is called incoming salt. In the transmission of incoming salt, differences in transmitted volume of incoming salts could occur according to the influences of local shoreline topography which includes surrounding weather conditions, types of building placements, obstacles of wind tunnel etc. And therefore, for the application of boundary conditions for durable offshore structure design against the salt attack, comparative analysis through wind tunnel test and fluid value simulation are executed in order to investigate the moving and adhesion process of incoming salt to offshore structure.

  • PDF

Damage detection of multistory shear buildings using partial modal data

  • Shah, Ankur;Vesmawala, Gaurang;Meruane, V.
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.1-11
    • /
    • 2022
  • This study implements a hybrid Genetic Algorithm to detect, locate, and quantify structural damage for multistory shear buildings using partial modal data. Measuring modal responses at multiple locations on a structure is both challenging and expensive in practice. The proposed method's objective function is based on the building's dynamic properties and can also be employed with partial modal information. This method includes initial residuals between the numerical and experimental model and a damage penalization term to avoid false damages. To test the proposed method, a numerical example of a ten-story shear building with noisy and partial modal information was explored. The obtained results were in agreement with the previously published research. The proposed method's performance was also verified using experimental modal data of an 8-DOF spring-mass system and a five-story shear building. The predicted results for numerical and experimental examples indicated that the proposed method is reliable in identifying the damage for multistory shear buildings.

팽창줄눈의 이론적 산정 (Theoretical Evaluation on Spacings of Expansion Joint)

  • 이홍재;이차돈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.455-458
    • /
    • 1999
  • It has been known that buildings having inappropriate expansion joints in their spacings may be subject to exterior damages due to extensive cracks on the outer walls under service loads, and structural damages due to excessive moment induced by temperature changes at ultimate load conditions. Rather inconsistent code provisions are available regarding spacings of expansion joints from different foreign structural codes and even worse, no quantiative measure on spacings is given in our codes for building structures. In order to establish a rational measure on the spacing of expansion joints, theoretical approaches are taken in this study. The developed theoretical formula is, then, converted to design chart for structural designer's convenience in its use. The chart considers both service and ultimate load stages.

  • PDF

Theoretical Development and Design Aids for Expansion Joint Spacings

  • Lee, Hong-Jae;Lee, Cha-Don
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.101-111
    • /
    • 2000
  • It has been a well known fact that buildings having inappropriate expansion joints in their spacings may be subject to exterior damages due to extensive cracks on the outer walls under service loads and structural damages due to excessive moment induced by temperature changes at ultimate load conditions. Unfortunately, consistent code provisions are unavailable regarding spacings of expansion joints from different foreign structural codes. And a more serious problem is that no quantitative measurements on spacings is given in our codes for building structures. In order to establish a rational guideline on the spacing of expansion joints, theoretical approaches are taken in this study. The developed theoretical formula is, then, converted to a design chart for structural designers' convenience in its use. The chart considers both service and ultimate load stages.

  • PDF

Proposing a Method for Robustness Index Evaluation of the Structures Based on the Risk Analysis of Main Shock and Aftershock

  • Abdollahzadeh, Gholamreza;Faghihmaleki, Hadi
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1710-1722
    • /
    • 2018
  • Investigating remained damages from terrible earthquakes, it could be concluded that some events including explosion because of defect and failure in the building mechanical facilities or caused by gas leak, firing, aftershocks, etc., which are occurred during or a few time after the earthquake, will increase the effects of damages. In this paper, by introducing a complete risk analysis which included direct and indirect risks for earthquake (the main shock) and aftershock, the corresponding robustness index was created that called as "robustness index sequential critical events risk-based". One of the main properties of the intended robustness index is using progressive collapse percentage in its evaluation. Then, in a numerical example for a 4-storey moment resisting steel frame structure, a method is presented for obtaining all effective parameters in robustness index evaluation based on the intended risk and at last its results were reported.