• Title/Summary/Keyword: Building boundary

Search Result 549, Processing Time 0.027 seconds

The Expressional Principles of Wooden Brackets in Jusimpo Style - Focusing on Temple building - (주심포식 공포의 표현원리 - 사찰건축과 그 지붕형태를 중심으로 -)

  • Choi, Go-Eun
    • Journal of architectural history
    • /
    • v.14 no.3 s.43
    • /
    • pp.103-118
    • /
    • 2005
  • This study is about the meaning of wooden brackets that are distinctive elements of wooden architecture in Korea, Japan, and China. Existing studies about wooden brackets have been limited to the boundary of formalism, so the object of this study is to make a breakthrough in the field of those studies. The Wooden brackets in this study are considered to be decorative elements, and the principles of their design are examined. The specific subject of the study is wooden architecture with Jusimpo-styled brackets that have brackets only on pillars. The definition of Jusimpo is reexamined first, and ChulMok-Ikkong which has not been regarded as a Jusimpo-styled wooden bracket is interpreted as Jusimpo-styled one in this study. Categorized into three types, Jusimpo is examined how it is expressed according to the type of the roof in a building. In view of the results, the wooden bracket system is an effective technique to express the formality, and two designing principles can be seen in Jusimpo; one that wooden brackets observed externally are standardized and regarded as the same ones, and the other that the style of wooden brackets used in the most formal building is Yi-ChulMok. These designing principles mean that the carpenter who was in charge of building the architecture had certain principles when expressing wooden brackets as well as the roofs according to the class of the architecture. In addition, although the styles of wooden brackets that were used in the most formal architecture during the Chosun period were mostly Dapo, Jusimpo in the form of Yi-ChulMok was also adopted in some temples depending on their scale, and that means Jusimpo-styled wooden brackets were never considered to be inferior to Dapo-styled ones. And this point leaves the argument that the reexamination of Jusimpo-styled wooden brackets which have been regarded as the style used in the attached building or small structures since the Choun dynasty should be conducted.

  • PDF

Large eddy simulation of wind effects on a super-tall building

  • Huang, Shenghong;Li, Q.S.
    • Wind and Structures
    • /
    • v.13 no.6
    • /
    • pp.557-580
    • /
    • 2010
  • A new inflow turbulence generation method and a combined dynamic SGS model recently developed by the authors were applied to evaluate the wind effects on 508 m high Taipei 101 Tower. Unlike the majority of the past studies on large eddy simulation (LES) of wind effects on tall buildings, the present numerical simulations were conducted for the full-scale tall building with Reynolds number greater than $10^8$. The inflow turbulent flow field was generated based on the new method called discretizing and synthesizing of random flow generation technique (DSRFG) with a prominent feature that the generated wind velocity fluctuations satisfy any target spectrum and target profiles of turbulence intensity and turbulence integral length scale. The new dynamic SGS model takes both advantages of one-equation SGS model and a dynamic production term without test-filtering operation, which is particular suitable to relative coarse grid situations and high Reynolds number flows. The results of comparative investigations with and without generation of inflow turbulence show that: (1) proper simulation of an inflow turbulent field is essential in accurate evaluation of dynamic wind loads on a tall building and the prescribed inflow turbulence characteristics can be adequately imposed on the inflow boundary by the DSRFG method; (2) the DSRFG can generate a large number of random vortex-like patterns in oncoming flow, leading to good agreements of both mean and dynamic forces with wind tunnel test results; (3) The dynamic mechanism of the adopted SGS model behaves adequately in the present LES and its integration with the DSRFG technique can provide satisfactory predictions of the wind effects on the super-tall building.

Noise and Vibration Characteristics of Floor Impact in a Test Building (표준실험동에서의 소음.진동 특성)

  • Jeong, Young;Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.92-95
    • /
    • 2005
  • In this study, Heavy-weight floor impact sound and vibration in concrete structures with different slab thickness have been measured in a test building. It was found that natural frequency increased according to increases of slab thickness, and acceleration level decreases. Results also show that the measurements in the 210 and 240mm slab structures are complied with the result from finite element analysis but the In and 180mm slab structures are not because the structures are constrained to the ground. Therefore, in modelling process the condition of sub-structures should be examined in relation to the boundary conditions.

  • PDF

A Study on the Applicability of Shrinkage Reduction Effect of Light-weight Aggregate Concrete (경량골재 콘크리트의 수축 저감효과에 관한 적용성 연구)

  • Lim, Sang-Jun;Bang, Chang-Joon;Park, Jong-Hyok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.175-176
    • /
    • 2011
  • Applying previous studies performed in the moisture transportation characteristics and shrinkage of lightweight concrete application of shrinkage reduction is to discuss. Applicability of shrinkage reduction effect of lightweight concrete applies for the analysis of PSC girder bridge beam placed on the construction site. Stress of the concrete bridge deck, rebar quantity is calculated by effective elastic modulus method and crack risk is assessed by moisture transport and differential shrinkage analysis. After approximately 10 days maximum tensile stress occurs 6MPa, similar to the case of normal concrete, a maximum tensile stress occurs 3MPa in lightweight concrete and comparing to normal concrete stress was reduced to approximately 50%. Normal and lightweight concrete crack index, respectively, is reduced 1.6 to 1.2, 1.2 to 0.9 in surface and boundary region. Therefore, reduction in shrinkage of concrete were able to confirm reduction of crack risk.

  • PDF

STUDY ON X-RAYS AND NEUTRONS LEAKED FROM A 45 MeV ELECTRON LINAC FACILITY

  • Sawamura, Sadashi;Kitaichi, Masatoshi;Nojiri, Ichiro;Yamada, Takuma;Kaneko, Junichi;Sawamura, Teruko
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.133-137
    • /
    • 2001
  • Spatial and time distributions of x-rays and neutrons from Hokkaido University 45 MeV electron linac facility were measured and compared with the calculation. In the calculation, x-rays in a Pb-target were evaluated using the EGS-code. The x-rays and the neutrons from the target to the facility building boundary and skyshine process outside the facility building were simulated with the EGS and the MCNP respectively.

  • PDF

Hot- Fire Injector Test for Determination of Combustion Stability Boundaries Using Model Chamber

  • Sohn Chae Hoon;Seol Woo-Seok;Shibanov Alexander A.;Pikalov Valery P.
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1821-1832
    • /
    • 2005
  • This study realizes the conceptual method to predict combustion instability in actual full-scale combustion chamber of rocket engines by experimental tests with model (sub-scale) chamber. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions, and hot-fire test procedures were followed to obtain stability boundaries. From the experimental tests, two instability regions are presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio, which are customary for combustor designers. It is found that instability characteristics in the chamber with the adopted jet injectors can be explained by the correlation between the characteristic burning or mixing time and the characteristic acoustic time: In each instability region, dynamic behaviors of flames are investigated to verify the hydrodynamically-derived characteristic lengths of the jet injectors. Large-amplitude pressure oscillation observed in upper instability region is found to be generated by lifted-off flames.

The coupling of complex variable-reproducing kernel particle method and finite element method for two-dimensional potential problems

  • Chen, Li;Liew, K.M.;Cheng, Yumin
    • Interaction and multiscale mechanics
    • /
    • v.3 no.3
    • /
    • pp.277-298
    • /
    • 2010
  • The complex variable reproducing kernel particle method (CVRKPM) and the FEM are coupled in this paper to analyze the two-dimensional potential problems. The coupled method not only conveniently imposes the essential boundary conditions, but also exploits the advantages of the individual methods while avoiding their disadvantages, resulting in improved computational efficiency. A hybrid approximation function is applied to combine the CVRKPM with the FEM. Formulations of the coupled method are presented in detail. Three numerical examples of the two-dimensional potential problems are presented to demonstrate the effectiveness of the new method.

Design Guidelines of Elevated Buildings for Antarctic Environment (I)-Wind Load (남극환경을 위한 고상식 건물의 Design Guideline에 관한 연구(I)-풍하중)

  • Kim, D. H.;Kwon, K.C.S.;Rohde H.F.
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.22-34
    • /
    • 1990
  • 남극환경은 남극의 거센 바람 및 이에 수반되는 적설현상을 피하기 위해 땅에서 띄우는 고상식 및 지하에 설치하는, 두가지의 형태를 취하고 있다. 고상식의 경우 건물밑으로 바람을 통하게 함으로써 적설현상을 피하는데 효과적이기는 하나 남극의 거센 바람에 대응하기 위하여 구조적인 문제를 해결해야 하는 취약점을 지니고 있다. 본 연구는 경계층난류풍하를 이용하여 고상식 남극건물에 가해지는 풍하중을 파악함으로서 남극건물의 design guide line을 제시하였다.

  • PDF

Corrosion Characteristics of hot rolled and thermo-mechanically treated steel rebar in concrete pore solution (콘크리트 기공 솔루션에서의 열간 압연 및 열 기계 처리 철근의 부식 특성)

  • Lee, Han-Seung;Singh, Jitendra Kumar
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.202-203
    • /
    • 2018
  • Chemistry and microstructure of steel reinforcement bars play an important role to control the corrosion in concrete environments. In present study, we have chosen two different microstructure of steel rebars produced from companies and assessed their corrosion characteristics in simulated concrete pore (SCP) solution with prolonged exposure periods. Hot rolled steel rebar showed more corrosion resistance compare to thermo-mechanically treated (TMT) one. The growth of passive is greater in hot rolled (A) than TMT (B) due to orientation of microstructure. TMT steel rebar exhibit distorted microstructure with many micro cells which enhances the galvanic coupling and induce the deterioration while on the other hand hot rolled rebars exhibit fine grain boundary which responsible in growth of uniform, adherent and protective passive film resultant improved impedance was observed.

  • PDF

Attachment Rate Analysis of Airborne Chlorides by Construction Finish Material to Measure the Amount of Chlorides on the Surface (표면염화물량 산정을 위한 건축마감재별 비래염분 부착율 분석)

  • Cho, Gyu-Hwan;Ji, Dong-Hun;Jung, Jae-Min;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.57-58
    • /
    • 2014
  • For durability design to protect against chloride-induced corrosion, it is important to estimate the amount of chlorides on the surface. However, it is difficult to estimate the airborne chlorides, a boundary condition, due to the difference between the amount of chlorides attached to a surface of an actual structure and that in the air. Therefore, in this study the attachment rate analysis of airborne chlorides was evaluated for 13 types of finish materials. As a result, despite differences in the amount of airborne chlorides according to the finishing type, it was found that 60 percent of airborne chlorides were attached to mortar, 30 percent were attached to steel, and 25 percent were attached to tiles compared with the amount of chlorides in the air.

  • PDF