• 제목/요약/키워드: Building application

검색결과 3,361건 처리시간 0.037초

GIS 데이터에 기반한 건물인구 가중치 적용 ERAM 모델에 관한 연구 (A Study on the Application of Building Population Weighting to ERAM Model Based on GIS Data)

  • 문성훈;박근송;최재필
    • 대한건축학회논문집:계획계
    • /
    • 제35권1호
    • /
    • pp.47-54
    • /
    • 2019
  • This study proposes a new ERAM model with building population weighting. Previous studies of applying weightings on ERAM model on the scale of urban space were focused on the relationship between the street and the human behavior. However, this study focuses on the influences that buildings give to human behavior and develops a building population weighted ERAM model. This research starts by analyzing ERAM model to its basic compositions, which are adjacency matrix and row vector. It applies building population weighting to the row vector, while previous studies put weightings in the adjacency matrix. Building population weighted ERAM model calculates the building population weighting based on GIS data, which provides objective and massive data of buildings in the urban scale. For the verification of the model, Insa-dong and Myeong-dong were analyzed with both ERAM model and building population weighted ERAM model. The results were analyzed through the correlation test with actual pedestrian population data of the two districts. As a result, the explanation ability of building population weighted ERAM model for the pedestrian population turned out to be higher than the ERAM model. Since building population weighted ERAM model has the structure that can be combined with other weighted ERAM models, it is expected to develop a multi-weighted ERAM model with better explanation ability as a further study.

Building structural health monitoring using dense and sparse topology wireless sensor network

  • Haque, Mohammad E.;Zain, Mohammad F.M.;Hannan, Mohammad A.;Rahman, Mohammad H.
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.607-621
    • /
    • 2015
  • Wireless sensor technology has been opened up numerous opportunities to advanced health and maintenance monitoring of civil infrastructure. Compare to the traditional tactics, it offers a better way of providing relevant information regarding the condition of building structure health at a lower price. Numerous domestic buildings, especially longer-span buildings have a low frequency response and challenging to measure using deployed numbers of sensors. The way the sensor nodes are connected plays an important role in providing the signals with required strengths. Out of many topologies, the dense and sparse topologies wireless sensor network were extensively used in sensor network applications for collecting health information. However, it is still unclear which topology is better for obtaining health information in terms of greatest components, node's size and degree. Theoretical and computational issues arising in the selection of the optimum topology sensor network for estimating coverage area with sensor placement in building structural monitoring are addressed. This work is an attempt to fill this gap in high-rise building structural health monitoring application. The result shows that, the sparse topology sensor network provides better performance compared with the dense topology network and would be a good choice for monitoring high-rise building structural health damage.

오픈 하우징 시스템을 적용한 소규모 아파트먼트 디자인에 관한 연구 - 가족형태에 대응하는 가변형 아파트먼트 평면계획 - (A Study on the Application of Open Housing System in Small-Size Apartments in Korea)

  • 김진희
    • 한국실내디자인학회논문집
    • /
    • 제14권1호
    • /
    • pp.73-80
    • /
    • 2005
  • Open Housing System ideas were developed in Korea in the 1980s to satisfy the demand for variety indwelling spaces. This domestic attempt to apply open building principles was highly restricted and was applied only in support of middle-large size apartments rather than small size apartments. One of the problems was the conventional design of building structures. It was difficult to effectively satisfy the various lifestyles and transformation of dwellings because existing apartments were designed using a concrete wall structure approach, in which room sizes and arrangements were fixed by the placement of structural concrete walls. This was the result not only of structural analysis (other structural designs were possible) but also the result of the idea that the standard plan was suitable for a stable society and was easier to implement, and that change in social standards and technical upgrading was not going to happen. This study presents an apartment concept in which open building design methods were applied to satisfy the problem of various lifestyles and household sizes and preferences for small apartments. This concept also helps to create a more effective and long lasting building which decreases construction waste, saves resources and protects the environment by enabling the building to accommodate combining, increasing / decreasing, changing location or changing usage of rooms.

냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구 (A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy)

  • 심세라;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

통계적 방법에 의한 건물 부하 산정 (Building Energy Load Estimation by a Statistical Method)

  • 정모;박화춘;임용훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.342-347
    • /
    • 2008
  • A Microsoft $Access^{(R)}$ application that estimates hourly building energy load is developed based on statistical field measurements. Hourly patterns of heating, hot water, cooling, and electricity loads are evaluated for an energy consuming community composed of various types of buildings. Popular building types such as apartments, offices, hotels and accomodations, stores, churches, schools and educational institutes are included in the model. For each type of buildings, hourly patterns for a month are measured and compiled to derive a 24-hour load distributions. Daily sum of heating, hot water, cooling, and electricity loads are also measured for the building types. The annual energy need profiles are generated by combining the 24-hour distribution and 365-day consumption patterns. The annual maximum values of the 8760 hours of a year for each load type serves as a guide for selecting a device capacity. A user-friendly interface that ushers users throughout the whole process is provided.

  • PDF

The Research and Application of Innovative High Efficient Construction Technologies in Super High Rise Steel Structure Building

  • Dai, Lixian;Liao, Biao
    • 국제초고층학회논문집
    • /
    • 제3권3호
    • /
    • pp.205-214
    • /
    • 2014
  • The super high rise building construction is characterized by a large quantity of engineering works and structural components, high demanding of construction technology and complex cross operations. As the height of super high rise building increases, the construction difficulties increase, it is challenging the steel structural building construction technology. In this paper, the key technologies in the construction of Chinese modern super high rise steel structure building have been studied. The innovative tower crane supporting frame suspension disassembly technology has been developed to allow the crane supporting frame to turnover in the air without occupying materials stockyard. A new self-elevating platform technique which is capable of striding over structural barriers has been developed. This new technology allows the platform to be self-elevated along variable cross section column with a maximum 600 mm size change. A new automatic submerged arc welding technology has also been developed to ensure the process continuity and quality stability of welding job on the construction site.

Application of meta-model based parameter identification of a seismically retrofitted reinforced concrete building

  • Yu, Eunjong
    • Computers and Concrete
    • /
    • 제21권4호
    • /
    • pp.441-449
    • /
    • 2018
  • FE models for complex or large-scaled structures that need detailed modeling of structural components are usually constructed using commercial analysis softwares. Updating of such FE model by conventional sensitivity-based methods is difficult since repeated computation for perturbed parameters and manual calculations are needed to obtain sensitivity matrix in each iteration. In this study, an FE model updating procedure avoiding such difficulties by using response surface (RS) method and a Pareto-based multiobjective optimization (MOO) was formulated and applied to FE models constructed with a commercial analysis package. The test building is a low-rise reinforced concrete building that has been seismically retrofitted. Dynamic properties of the building were extracted from vibration tests performed before and after the seismic retrofits, respectively. The elastic modulus of concrete and masonry, and spring constants for the expansion joint were updated. Two RS functions representing the errors in the natural frequencies and mode shape, respectively, were obtained and used as the objective functions for MOO. Among the Pareto solutions, the best compromise solution was determined using the TOPSIS (Technique for Order of Preference by Similarity to Ideal Solution) procedure. A similar task was performed for retrofitted building by taking the updating parameters as the stiffness of modified or added members. Obtained parameters of the existing building were reasonably comparable with the current code provisions. However, the stiffness of added concrete shear walls and steel section jacketed members were considerably lower than expectation. Such low values are seemingly because the bond between new and existing concrete was not as good as the monolithically casted members, even though they were connected by the anchoring bars.

건축물 에너지 시뮬레이션 적용을 위한 목재 열전도율 데이터베이스 구축 (Wood Thermal Conductivity Database Construction for the Application of Building Energy Simulation)

  • 서정기;강유진;김수민
    • 한국가구학회지
    • /
    • 제27권2호
    • /
    • pp.122-127
    • /
    • 2016
  • The increasing interest in the environment and climate change around the globe, while the importance of building energy saving is increasing. The building energy simulation program is used for evaluating of energy performance of buildings. However, an input value of wood thermal conductivity in the programs is different from each other. Therefore, in this study, wood thermal conductivity was measured according to species. Through construction database by species of wood, the error of simulation program are able be decreased. In addition, if used as a structural and interior of buildings, the thermal conductivity and moisture of the wood is difficult to apply to the program because they were changed according to the occupant's lifestyle. In this paper, thermal conductivity and moisture content.of wood confirmed changes in the constant temperature and relative humidity ($25^{\circ}C$, 50% R.H.) condition.

보일러빌딩 내부 환기현상에 관한 수치적 연구 (Numerical Study on the Ventilation Effect in the Boiler Building)

  • 김철환;유근종;최훈기
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.239-249
    • /
    • 2005
  • Ventilation effect is analyzed for boiler building with multiple heat sources. Air flow inside the boiler building is characterized as turbulent mixed convection. Analysis methodology is set up with two different $k-{\varepsilon}$ type models (standard $k-{\varepsilon}$, RNG $k-{\varepsilon}$). Two different cases with high and low outside temperature are analyzed. In case of high outside temperature condition, mixed convection is well realized inside the boiler building. With different upper louver opening rate, air flow is also well established and proper opening rate is found to meet design limit in case of low outside temperature condition. Difference of analysis results for two different turbulence models are not significant. Therefore, analysis methodology with simple $k-{\varepsilon}$ turbulence model is found to be reliable for the boiler building ventilation analysis. However, more simplified geometrical model is desired to expand its application.

개방형BIM기반의 건축법규검토를 위한 법규유형화 및 적용방안 (Building Code Typology and Application for Open BIM based Code Checking)

  • 김인한;김용하;최중식
    • 한국CDE학회논문집
    • /
    • 제19권3호
    • /
    • pp.224-235
    • /
    • 2014
  • Recently, Productivity of the construction industry has been decreasing than other industries. Because of this, BIM is being spread in the construction industry. However, quality criteria for BIM data is insufficient. Regulation information is an important factor for initial architectural design evaluations. However, building code and related regulation are numerous. National building code structure in Korea is much more complex than other countries. The purpose of this study is to suggest the typology method of building code and apply to real regulations. To achieve this purpose, the authors have extracted required information to from original regulation for code checking and suggested mapping methods between extracted information and information of IFC scheme. In addition, the authors have represented EXPRESS-G diagram for extracting information from IFC scheme and suggested code checking method through stair case. Output of this study can be used as a base line data for automated code checking system based on open BIM. Automated code checking system will be utilized in architectural design evaluations and supported to increase design quality. It can be used to mount in SEUMTER that is the construction administration system of Ministry of Land, Infrastructure and Transport (MOLIT).