• 제목/요약/키워드: Building Structure Standards

검색결과 146건 처리시간 0.025초

A Study on the Method of Blasting Demolition of Reinforced Concrete Structures (RC구조물 발파해체공법 연구)

  • 최영천
    • Explosives and Blasting
    • /
    • 제20권3호
    • /
    • pp.83-96
    • /
    • 2002
  • Reconstruction and redevelopment of old and dilapidated apartment and housing have been increasing to provide more housing accommodation and to secure the safety of building structures since the middle of 1990's. Since, however, little researches on the demolition technique have been made, conventional mechanical demolition method were applied to the most of works that resulted in flooding in small demolition companies. Problems associated with mechanical demolition method are increase not only in working days and costs, but also in public claims, particularly for high-rise building structures. This is to contribute the demolition industries bt providing the concept, standards, and technique of demolition engineering while maximizing working efficiency and minimizing public claims.

Foundation Research for Reinforced Concrete Substitution Grounding Electrode (철근콘크리트 대용접지극에 관한 기초 연구)

  • Kim, Sung-Sam;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2004
  • There are ground facility of maintenance in house electric facility of infra maintenance electric home appliances having used multifariousness in house, that use electric energy of common source for equipment. The body of building such as the reinforced concrete construction is structurally united, and the electric resistance is also small. It is possible that those foundations have contacted the ground at large surface area and that it substitutes the building construction body for the earth electrode. This is called "the structure earthing". This method has been defined at electrical facilities technical standards and KS in our country, and it has been used in various quarters practically. However, in our country, there is no example of using the foundation of the house as substitution earth electrode practically, and the means of the evaluation as electrode has not been established either. Then, in this paper, basic research for utilizing foundation of the house as substitution earth electrode is carried out.

  • PDF

A Study on the Changed by Spatial Structure Element for the Space Planning of Apartment Complex (아파트 단지 계획을 위한 공간구성요소의 변화 분석)

  • 오진안
    • Journal of the Korean housing association
    • /
    • 제7권2호
    • /
    • pp.91-98
    • /
    • 1996
  • View From the point of change of the land of the land of the nation. The advancement in the modern civilization has led to building many apartments characterized by high buildings and building complexes due to population concentration into big cities. This tendency not only causes serious problems in terms of city images but also produces considerable discords in the matter of harmonized beauty of the complex itself.At the stage of space planning for the apartment complexes only economic and functional aspects were considered. So in many cases the space, which dose not contribute to environmental improvement which must go in parallel with the quantity increase of apartments and improvements of welfare and living standards of the apartment inhabitants.

  • PDF

Strength Properties of Multi-layered Insulation according to the Type of Configuration (다층형 단열재의 구성 형식에 따른 강도 특성 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2019
  • As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.

  • PDF

(A)Study on Apartment Insulation Status and Insulation reinforcement Application (공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구)

  • Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

Chemically Resistant Characteristic Analysis of the Liquid-Applied Membrane Waterproofing Materials of Rapid Hardening Spray Type Applied on the Concrete Structure (콘크리트 구조물에 적용되는 초속경 분사시공 도막 방수재료의 내화학 특성 분석 -폴리우레아, 폴리우레탄·우레아, 폴리우레탄 수지계 방수재료를 중심으로-)

  • Kim, Yun-Ho;Choi, Eun-Kyu;Park, Jin-Sang;Kim, Su-Ryun;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.168-169
    • /
    • 2013
  • In this study, the chemical resistance of polyurea resin waterproofing and anti-corrosion materials that is applied to the social infrastructure was analyzed. The result in this study will be utilizing as a basic data for establishing the quality standards which are able to judge the chemically resistant characteristic of polyurea resin waterproofing and anti-corrosion materials.

  • PDF

Establishment of Korea-China joint quality standards and improvement the performance of Non-hardening Waterproofing Material (비경화 방수재의 한·중 공동품질기준 마련 및 성능개선 연구)

  • Choi, Su-Young;An, Hyun-Ho;Choi, Young Hyun;Park, Wan-Goo;Kim, Dong-Bum;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.224-225
    • /
    • 2019
  • The purpose of this study was to develop a technology to prevent leakage of construction structures for the Chinese market. The first key development factor is to establish a joint quality standard that corresponds to all performance criteria set out in Chinese Standard JC / T 2428-2017. The second key development factor is to develop a product capable of exhibiting performance in a low temperature environment of $-30^{\circ}C$ and coping with 15mm structure behavior.

  • PDF

A Study on the Improvement Plan of Reusable Pipe Support Certification System (재사용 파이프서포트 인증제도의 개선방안 연구)

  • Moon, Seong-Oh;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2020
  • Pipe support is a representative structure that supports slab formwork, and it is a representative temporary equipment that has been systematically managed since the 1990s when the domestic temporary equipment performance test system was introduced. Nevertheless, it is also a reality that many of the products in circulation are used products that are reused and do not meet the performance of the initial manufacturing stage. However, if only new products are insisted, it could lead to delays in the process due to an increase in construction costs and difficulties in timely delivery. On the contrary, it is not acceptable for the safety of the construction site to use products of low quality without verification procedures or standards. Therefore, this study attempts to grasp the management system such as safety certification for temporary equipment and the actual condition of quality control to maintain performance, and propose improvement plans.

  • PDF

An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses- (건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 -)

  • Lee, Su-In;Kim, Jeong-Gook;Kim, Seo-Hun;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results (방수재료 및 공법의 내구성 평가를 위한 복합열화분석용 3차원 거동대응 시험결과)

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.189-190
    • /
    • 2018
  • KS standards mostly relate to single component material evaluation, so in cases of underground structure environments, most cannot predict the existing composite forms of deterioration, resulting in the applied waterproofing materials becoming unable to respond to these damaging factors. Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material.

  • PDF