• Title/Summary/Keyword: Building Response

Search Result 1,889, Processing Time 0.026 seconds

Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper

  • Amini, F.;Doroudi, R.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.2
    • /
    • pp.181-195
    • /
    • 2010
  • Coupled building control is a viable method to protect tall buildings from seismic excitation. In this study, the semi-active control of a building complex is investigated for mitigating seismic responses. The building complex is formed of one main building and one podium structure connected through Magneto-Rheological (MR) Dampers and Tuned Mass Damper. The conventional semi-active control techniques require a primary controller as a reference to determine the desired control force, and modulate the input voltage of the MR damper by comparing the desired control force. The fuzzy logic directly determines the input voltage of an MR damper from the response of the MR damper. The control performance of the proposed fuzzy control technique for the MR damper is evaluated for the control problem of a seismically-excited building complex. In this paper, a building complex that include a 14-story main building and an 8-story podium structure is applied as a numerical example to demonstrate the effectiveness of semi-active control with Magneto-Rheological dampers and its comparison with the passive control with the Tuned Mass Damper and two uncoupled buildings and hybrid semi-active control including the Tuned Mass Damper and Magneto-Rheological dampers while they are subject to the earthquake excitation. The numerical results show that semi-active control and hybrid semi-active control can significantly mitigate the seismic responses of both buildings, such as displacement and shear force responses, and fuzzy control technique can effectively mitigate the seismic response of the building complex.

Validation of Extended Building Heat Transfer Model (건축전열모델의 확장에 관한 연구)

  • 조민관
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.422-431
    • /
    • 2003
  • Theory of the building heat transfer is generally limited to the heat flux to the surfaces of windows and walls, which influences the indoor climate of a building, in the field of architectural environmental engineering. While the heat flux from the buildings to their environment has been considered in the viewpoint of urban climate, its conventional theory have been rarely examined. The purpose of this study is to propose a building-urban heat transfer model for defining the relation between the building and the urban climate by extending the building heat transfer model. In this study, the extended building heat transfer model, where response factor method is used, is established on the urban space and the indoor space by the boundary of building envelopes. Computer simulation (HASP/ACLD) is conducted on the subjected urban area by the established building-urban heat transfer model. As a result it is logically proved that the short waves of solar radiation, which interact with long Waves of radiation from the buildings and the earth, increase the urban air temperature ana buildings largely influence on the urban climate.

ReliabIlity analysis of containment building subjected to earthquake load using response surface method

  • Lee, Seong Lo
    • Computers and Concrete
    • /
    • v.3 no.1
    • /
    • pp.1-15
    • /
    • 2006
  • The seismic safety of reinforced concrete containment building can be evaluated by probabilistic analysis considering randomness of earthquake, which is more rational than deterministic analysis. In the safety assessment of earthquake-resistant structures by the deterministic theory, it is not easy to consider the effects of random variables but the reliability theory and random vibration theory are useful to assess the seismic safety with considering random effects. The reliability assessment of reinforced concrete containment building subjected to earthquake load includes the structural analysis considering random variables such as load, resistance and analysis method, the definition of limit states and the reliability analysis. The reliability analysis procedure requires much time and labor and also needs to get the high confidence in results. In this study, random vibration analysis of containment building is performed with random variables as earthquake load, concrete compressive strength, modal damping ratio. The seismic responses of critical elements of structure are approximated at the most probable failure point by the response surface method. The response surface method helps to figure out the quantitative characteristics of structural response variability. And the limit state is defined as the failure surface of concrete under multi-axial stress, finally the limit state probability of failure can be obtained simply by first-order second moment method. The reliability analysis for the multiaxial strength limit state and the uniaxial strength limit state is performed and the results are compared with each other. This study concludes that the multiaxial failure criterion is a likely limit state to predict concrete failure strength under combined state of stresses and the reliability analysis results are compatible with the fact that the maximum compressive strength of concrete under biaxial compression state increases.

Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Stair-Installation Kagome Damping System (계단 설치형 카고메 감쇠시스템을 활용한 철근콘크리트 라멘조 공동주택의 지진응답 개선)

  • Hur, Moo-Won;Chun, Young-Soo;Lee, Sang-Hyun;Hwang, Jae-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.23-30
    • /
    • 2018
  • Recently, there are highly interests on structural damping to improve resistance of seismic and wind. It has been frequently used hysteresis damping devices made of steel because of economic efficiency, construction, and maintenance. This paper presents the effective reduction of seismic response by using Kagome damping system(SKDS) in rahmen system apartment building. The proposed system is designed to be activated by the relative displacement between the building and the stairs. It is performed nonlinear dynamic analysis to review the effects of earthquake response reduction for the 20-stories rahmen framed apartment building. In the analysis of the SKDS system, the reduction of maximum response displacement, maximum response acceleration and layer shear force are compared with the seismic design, and the result show that allowable story displacement is satisfied with Korean Building Code (KBC 2016).

Should accidental eccentricity be eliminated from Eurocode 8?

  • Anagnostopoulos, S.A.;Kyrkos, M.T.;Papalymperi, A.;Plevri, E.
    • Earthquakes and Structures
    • /
    • v.8 no.2
    • /
    • pp.463-484
    • /
    • 2015
  • Modern codes for earthquake resistant building design require consideration of the so-called accidental design eccentricity, to account for torsional response caused by several factors not explicitly considered in design. This provision requires that the mass centres in the building floor be moved a certain percentage of the building's dimension (usually 5%) along both the x and y axes and in both positive and negative directions. If one considers also the spatial combinations of the two component motion in a dynamic analysis of the building, the number of required analyses and combinations increases substantially, causing a corresponding work load increase for practicing structural engineers. Another shortcoming of this code provision is that its introduction has been based primarily on elastic results from investigations of oversimplified, hence questionable, one story building models. This problem is addressed in the present paper using four groups of eccentric braced steel buildings, designed in accordance with Eurocodes 3 (steel) and 8 (earthquake design), with and without accidental eccentricities considered. The results indicate that although accidental design eccentricities can lead to somewhat reduced inelastic response demands, the benefit is not significant from a practical point of view. This leads to suggestions that accidental design eccentricities should probably be abolished or perhaps replaced by a simpler and more effective design provision, at least for torsionally stiff buildings that constitute the vast majority of buildings encountered in practice.

Effects of Isolation Period Difference and Beam-Column Stiffness Ratio on the Dynamic Response of Reinforced Concrete Buildings

  • Chun, Young-Soo;Hur, Moo-Won
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.4
    • /
    • pp.439-451
    • /
    • 2015
  • This study analyzed the isolation effect for a 15-story reinforced concrete (RC) building with regard to changes in the beam-column stiffness ratio and the difference in the vibration period between the superstructure and an isolation layer in order to provide basic data that are needed to devise a framework for the design of isolated RC buildings. First, this analytical study proposes to design RC building frames by securing an isolation period that is at least 2.5 times longer than the natural vibration period of a superstructure and configuring a target isolation period that is 3.0 s or longer. To verify the proposed plan, shaking table tests were conducted on a scaled-down model of 15-story RC building installed with laminated rubber bearings. The experimental results indicate that the tested isolated structure, which complied with the proposed conditions, exhibited an almost constant response distribution, verifying that the behavior of the structure improved in terms of usability. The RC building's response to inter-story drift (which causes structural damage) was reduced by about one-third that of a non-isolated structure, thereby confirming that the safety of such a superstructure can be achieved through the building's improved seismic performance.

Feasibility study on using crowdsourced smartphones to estimate buildings' natural frequencies during earthquakes

  • Ting-Yu Hsu;Yi-Wen Ke;Yo-Ming Hsieh;Chi-Ting Weng
    • Smart Structures and Systems
    • /
    • v.31 no.2
    • /
    • pp.141-154
    • /
    • 2023
  • After an earthquake, information regarding potential damage to buildings close to the epicenter is very important during the initial emergency response. This study proposes the use of crowdsourced measured acceleration response data collected from smartphones located within buildings to perform system identification of building structures during earthquake excitations, and the feasibility of the proposed approach is studied. The principal advantage of using crowdsourced smartphone data is the potential to determine the condition of millions of buildings without incurring hardware, installation, and long-term maintenance costs. This study's goal is to assess the feasibility of identifying the lowest fundamental natural frequencies of buildings without knowing the orientations and precise locations of the crowds' smartphones in advance. Both input-output and output-only identification methods are used to identify the lowest fundamental natural frequencies of numerical finite element models of a real building structure. The effects of time synchronization and the orientation alignment between nearby smartphones on the identification results are discussed, and the proposed approach's performance is verified using large-scale shake table tests of a scaled steel building. The presented results illustrate the potential of using crowdsourced smartphone data with the proposed approach to identify the lowest fundamental natural frequencies of building structures, information that should be valuable in making emergency response decisions.

An efficient optimization approach for wind interference effect on octagonal tall building

  • Kar, Rony;Dalui, Sujit Kumar;Bhattacharjya, Soumya
    • Wind and Structures
    • /
    • v.28 no.2
    • /
    • pp.111-128
    • /
    • 2019
  • In this paper an octagon plan shaped building (study building) in presence of three square plan shaped building is subjected to boundary layer wind flow and the interference effects on the study building is investigated using Computational fluid dynamics. The variation of the pressure coefficients on different faces of the octagon building is studied both in isolated and interference conditions. Interference Factors (IF) are calculated for different faces of the study building which can be a powerful tool for designing similar plan shaped buildings in similar conditions. A metamodel of the IF, in terms of the distances among buildings is also established using Response Surface Method (RSM). This set of equations are optimized to get the optimum values of the distances where the IF is unity. An upstream Interference zone for this building setup and wind environment is established from these data. Uncertainty principle is also utilised to determine the optimum positions of the interfering buildings considering the uncertain nature of wind flow for minimum interference effect. The proposed procedure is observed to be computationally efficient in deciding optimum layout at buildings often required in city planning. The results show that the proposed RSM-based optimization approach captures the interference zone accurately with substantially less number of experiments.

A study on nonlinear seismic response analysis of building considering frequency dependent soil impedance in time domain

  • Nakamura, Naohiro
    • Interaction and multiscale mechanics
    • /
    • v.2 no.1
    • /
    • pp.91-107
    • /
    • 2009
  • In order to accurately estimate the seismic behavior of buildings, it is important to consider both nonlinear characteristics of the buildings and the frequency dependency of the soil impedance. Therefore, transform methods of the soil impedance in the frequency domain to the impulse response in the time domain are needed because the nonlinear analysis can not be carried out in the frequency domain. The author has proposed practical transform methods. In this paper, seismic response analyses considering frequency dependent soil impedance in the time domain are shown. First, the formulation of the proposed transform methods is described. Then, the linear and nonlinear earthquake response analyses of a building on 2-layered soil were carried out using the transformed impulse responses. Through these analyses, the validity and efficiency of the methods were confirmed.

Simulation of Artificial Earthquake Wave Compatible with Seismic Design Spectrum and Its Response Characteristics (내진 설계용 스펙트럼에 적합한 인공지진파의 작성과 응답 특성)

  • Jun, Dae-Han;Kang, Pyeong-Doo;Kim, Jae-Ung
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.141-148
    • /
    • 2006
  • This study describes a generation of artificial earthquake wane compatible with seismic design spectrum. In seismic response analysis of building structures, the input ground accelerations have considerable effect on dynamic characteristics of structures. Therefore, it is important to properly select input ground motions for seismic response analysis. In this paper, the artificial earthquake wave are generated according to previously recorded earthquake waves in past earthquake events. The artificial wave have identical phase angles to the recorded earthquake wane, and their overall response spectra are compatible with seismic design spectrum with 5% of critical viscous damping. Each simulated earthquake wave has a identical phase angles to the original recorded ground acceleration, and match to design response spectra in the range of period from 0.02 to 10.0 seconds. It is concluded that the artificial earthquake waves simulated in this paper ate applicable as input ground motions for a seismic response analysis of building structures.

  • PDF