• Title/Summary/Keyword: Building IT Convergence

Search Result 648, Processing Time 0.029 seconds

A study on improving self-inference performance through iterative retraining of false positives of deep-learning object detection in tunnels (터널 내 딥러닝 객체인식 오탐지 데이터의 반복 재학습을 통한 자가 추론 성능 향상 방법에 관한 연구)

  • Kyu Beom Lee;Hyu-Soung Shin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.2
    • /
    • pp.129-152
    • /
    • 2024
  • In the application of deep learning object detection via CCTV in tunnels, a large number of false positive detections occur due to the poor environmental conditions of tunnels, such as low illumination and severe perspective effect. This problem directly impacts the reliability of the tunnel CCTV-based accident detection system reliant on object detection performance. Hence, it is necessary to reduce the number of false positive detections while also enhancing the number of true positive detections. Based on a deep learning object detection model, this paper proposes a false positive data training method that not only reduces false positives but also improves true positive detection performance through retraining of false positive data. This paper's false positive data training method is based on the following steps: initial training of a training dataset - inference of a validation dataset - correction of false positive data and dataset composition - addition to the training dataset and retraining. In this paper, experiments were conducted to verify the performance of this method. First, the optimal hyperparameters of the deep learning object detection model to be applied in this experiment were determined through previous experiments. Then, in this experiment, training image format was determined, and experiments were conducted sequentially to check the long-term performance improvement through retraining of repeated false detection datasets. As a result, in the first experiment, it was found that the inclusion of the background in the inferred image was more advantageous for object detection performance than the removal of the background excluding the object. In the second experiment, it was found that retraining by accumulating false positives from each level of retraining was more advantageous than retraining independently for each level of retraining in terms of continuous improvement of object detection performance. After retraining the false positive data with the method determined in the two experiments, the car object class showed excellent inference performance with an AP value of 0.95 or higher after the first retraining, and by the fifth retraining, the inference performance was improved by about 1.06 times compared to the initial inference. And the person object class continued to improve its inference performance as retraining progressed, and by the 18th retraining, it showed that it could self-improve its inference performance by more than 2.3 times compared to the initial inference.

CFD Simulation of Changesin NOX Distribution according to an Urban Renewal Project (CFD 모델을 이용한 도시 재정비 사업에 의한 NOX 분포 변화 모의)

  • Kim, Ji-Hyun;Kim, Yeon-Uk;Do, Heon-Seok;Kwak, Kyung-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.3
    • /
    • pp.141-154
    • /
    • 2021
  • In this study, the effect of the restoration of Yaksa stream and the construction of an apartment complex by the urban renewal project in the Yaksa district of Chuncheon on air quality in the surrounding area was evaluated using computational fluid dynamics (CFD) model simulations. In orderto compare the impact of the project, wind and pollutant concentration fields were simulated using topographic data in 2011 and 2017, which stand for the periods before and after the urban renewal project, respectively. In the numerical experiments, the scenarios were set to analyze the effect of the construction of the apartment complex and the effect of stream restoration. Wind direction and wind speed data obtained from the Chuncheon Automated Synoptic Observing System (ASOS) were used as the inflow boundary conditions, and the simulation results were weighted according to the frequencies of the eight-directional inflow wind directions. The changes in wind speed and NOX concentration distribution according to the changes in building and terrain between scenarios were compared. As a result, the concentration of NOX emitted from the surrounding roads increased by the construction of the apartment complex, and the magnitude of the increase was reduced as the result of including the effect of stream restoration. The concentration of NOX decreased around the restored stream, while the concentration increased significantly around the constructed apartment complex. The increase in the concentration of NOX around the apartment complex was more pronounced in the place located in the rear of the wind direction to the apartment complex, and the effect remains up to the height of the building. In conclusion, it was confirmed that the relative arrangement of apartment complex construction and stream restoration in relation to the main wind direction of the target area was one of the major factors in determining the surrounding air quality.

A Study of Introducing Virtual Reality for Fire Disaster Preparedness Training (화재재난 대비훈련을 위한 가상현실의 도입방안 연구)

  • Kim, Jong Kouk;Han, Dong-Ho
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.299-306
    • /
    • 2018
  • As recent Jecheon and Milyang fire cases show, the need for fire disaster training to prepare for a fire disaster continues to grow. In the event of a disaster, people become mentally confused and are called disaster personalities. In order to survive in a disaster, it is necessary to develop the power to overcome the disaster personality by experiencing the disaster situation in advance. Therefore, training to overcome disaster personality is needed, and virtual reality can be a good training means in that it can experience without physical space. In addition, periodic actual disaster evacuation drills should be carried out to compensate for the shortcomings of virtual reality. In order to introduce fire disaster drill using virtual reality and to spread it to the public, the Korea National VR project should be introduced which benchmarked national PC project which succeeded in the past informatization project. Besides, the Korea National Safety Point system should be integrated to cover disaster preparedness training and building reinforcement. If the national VR project and the national safety point system are introduced successfully, Korea will be the basis for escaping the disgraceful nickname of 'disaster republic'.

A Study on CPPS Architecture integrated with Centralized OPC UA Server (중앙 집중식 OPC UA 서버와 통합 된 CPPS 아키텍처에 관한 연구)

  • Jo, Guejong;Jang, Su-Hwan;Jeong, Jongpil
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.73-82
    • /
    • 2019
  • In order to build a smart factory, building a CPPS (Cyber Physical Product System) is an important system that must be accompanied. Through the CPPS, it is the reality of smart factories to move physical factories to a digital-based cyber world and to intelligently and autonomously monitor and control them. But The existing CPPS architectures present only an abstract modeling architecture, and the research that applied the OPC UA Framework (Open Platform Communication Unified Architecture), an international standard for data exchange in the smart factory, as the basic system of CPPS It was insufficient. Therefore, it is possible to implement CPPS that can include both cloud and IoT by collecting field data distributed by CPPS architecture applicable to actual factories and concentrating data processing in a centralized In this study, we implemented CPPS architecture through central OPC UA Server based on OPC UA conforming to central processing OPC UA Framework, and how CPPS logical process and data processing process are automatically generated through OPC UA modeling processing We have proposed the CPPS architecture including the model factory and implemented the model factory to study its performance and usability.

A Case Study on the Islanding Detection Protection of PV System and ESS System (태양광 발전과 ESS 시스템의 연계운전시 단독운전 방지 사례 연구)

  • Lim, Jong Rok;Hwang, Hye-Mi;Shin, Woo Gyun;Ju, Young-Chul;Jung, Young Seok;Kang, Gi-Hwan;Ko, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.59-66
    • /
    • 2019
  • BIPV or BAPV installation applied to building is increasing through public utility mandates enterprise. Solar PV energy generates only during the day, but if it is operated in convergence with ESS, which stores electrical energy, it can restrain the fossil energy used in buildings throughout the day. A solution is to converge with PV system and ESS. However, PV systems and ESS connected to the power grid in parallel can cause problems of electrical stability. A study was conducted on the case of failure to detect islanding operation under the parallel operation of PV generation and ESS that are connected in parallel to power grid. Experiments conducted various non-islanding detections under the operating conditions. In the experiment results, when one PCS - PV inverter or ESS inverter - was operating under the islanding condition, it stopped working within 0.5 seconds of the Korean grid standard. However, when both of PV inverter and ESS inverter were operating at the same time under the islanding situation, the anti-islanding algorithm did not operate normally and both inverters continuously supplied power to the connected RLC loads. islanding detection Algorithm developed by each inverter manufacturer has caused this phenomenon. Therefore, this paper presented a new test standard for islanding detection.

A study on the selection of candidates for public bases according to the spatial distribution characteristics Automated External Defibrillator in Daegu City (대구시 자동심장충격기 공간분포 특성에 따른 공공 거점후보지 선정 연구)

  • Beak, Seong Ryul;Kim, Jun Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.599-610
    • /
    • 2020
  • The AED (Automated External Defibrillator) is not evaluated for spatial accuracy and temporal availability even if it is located within a building or a specific area that needed necessary to partition by spatial analysis and location allocation analysis. As a result of the analysis, the spatial analysis was performed using the existing public data of AED with applied the GIS location analysis method. A public institution (119 safety center, police box) was selected as a candidate for a public AED base that can operate 24 hours a day, 365 days a year according to the characteristics of each residential area. In addition, Thiessen Polygons were created for each candidate site and divided by regions. In the analysis of the service was analyzed regional in terms of accessibility to emergency medical services in consideration of the characteristics of AED, that emergency vehicles could arrive within 4 minutes of the time required for emergency medical treatment in most areas of the study area, but it did not areas outside of the city center. As a result, It was found that the operation of the AED base service center centered on vehicles of public institutions is effective for responding to AED patients at night and weekend hours. 19 Safety Center under and police box the jurisdiction of Daegu City to establish an AED service center for public institutions, location-based distance, attribute analysis, and minimization of overlapping areas that the method of using a vehicle appeared more efficient than using the existing walking type AED.

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.

A Study on Success Factors of Global Strategy of Cultural Content Company: Focusing on Iconix (문화콘텐츠기업 글로벌전략의 성공 요인에 관한 연구: 아이코닉스를 중심으로)

  • Han, JooHee;Choi, MyeongCheol;Zhang, MengTian
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.337-342
    • /
    • 2021
  • The purpose of this study is to analyze the environment and strategic behaviors of cultural contents companies with a focus on Iconix, and to derive strategic recommendations for Iconix to pursue in order to create a sustainable competitive advantage. As a result of the analysis, Iconix is a vertically integrated development-business system from content planning to business in line with their mission to develop into an all-weather entertainment content provider that can confidently compete with the major players in the US and Europe that are already leading the global market. It is building a strong global business network covering both domestic and overseas markets in stages, taking a high-level global strategy. However, depending on Pororo's success or due to various problems within the organizational structure, it is facing limitations. Therefore, if the various strategic suggestions presented in this study are implemented based on the One Source Multi Channel/Multi Use strategy that can maximize the added value of contents through the participation and business linkage of leading companies in each sector of the entertainment industry, the total entertainment will be stabilized. It will establish itself as a leader in the contents industry.

A Study on Ways to Improve Safety Management through Analysis of Fire Cases in Multiple-user Buildings (다중이용업소의 화재사례 분석을 통한 안전관리 개선방안 연구)

  • Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.191-201
    • /
    • 2022
  • In this study, we are going to derive problems for fire and safety management in multiple-user Buildings and suggest improvement measures to prevent recurrence through analysis of legal operation status for safety management of multiple-user Buildings and case studies of large-scale fires in multiple-user Buildings. For this study, first, the current state of the industry and fire occurrence status were investigated through theoretical considerations of the multi-use industry, and then the previous research on the multi-use industry was analyzed. and by analyzing the legal and institutional status of multiple-user Buildings, problems were derived through cases such as the Jecheon fire in Chungcheongbuk-do, the Inhyeon-dong fire in Incheon, and the Songpa-gu fire in Seoul. As a result, first, the necessity of strengthening the initial fire response capability. Second, thorough maintenance and management of emergency exits. Third, the need for rational regulation of upholstery. Fourth, reinforcement of fire safety education and training. Fifth, strengthening of installation standards for firefighting and safety facilities. Sixth, we derive the result that it is necessary to raise awareness about safety management, compare and analyze it with legal and institutional contents, and suggest solutions accordingly. When looking at the causes of fires in multi-use buildings, building owners, business owners, and employees think that there is no possibility of a fire occurring in their business premises, so there is a lack of awareness. It is necessary to raise awareness through education and publicity of firefighters and related administrative agencies.

Relationship between Nursing Students' Nursing Competency, Clinical Reasoning Competence and Empathy Ability according to the Enneagram Center of Power (에니어그램 힘의중심에 따른 간호대학생의 간호역량, 임상추론역량 및 공감능력의 관계)

  • Shin Eun Sun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.373-382
    • /
    • 2024
  • This study attempted to identify the relationship between nursing competency, clinical reasoning competence, and empathy ability according to the center of enneagram power for nursing students. The subjects of the study were 218 students enrolled in the department of nursing at two universities located in one region, data collection was conducted from 16 October to 27 October 2023. Data analysis was performed using SPSS/WIN version 26.0 program, descriptive statistics, and difference verification were analyzed by t-test, ANOVA, pearson's correlation coefficient, Results, The enneagram personality type of the subjects of this study was the most common type 9. And in the enneagram center of power, the instinct-centered type had the highest nursing competence, the thought-centered type had the highest clinical reasoning competence, and the emotion-centered type had the highest empathy ability. In addition, nursing competence and clinical reasoning competence showed a significant positive correlation, and clinical reasoning competence and empathy ability were also found to be positively correlated. Therefore, it is important to continue to develop and apply individualized competency building programs that reflect personality type tests to nursing students. In addition, the higher the empathy ability, the higher the clinical reasoning competence, so it is thought that it is necessary to develop a standardized curriculum that can improve nursing competence and clinical reasoning competence and verify its effectiveness.