• Title/Summary/Keyword: Building Heights

Search Result 164, Processing Time 0.02 seconds

Earthquake induced structural pounding between adjacent buildings with unequal heights considering soil-structure interactions

  • Jingcai Zhang;Chunwei Zhang
    • Earthquakes and Structures
    • /
    • v.24 no.3
    • /
    • pp.155-163
    • /
    • 2023
  • The purpose of this paper is to investigate the coupled effect of SSI and pounding on dynamic responses of unequal height adjacent buildings with insufficiently separation distance subjected to seismic loading. Numerical investigations were conducted to evaluate effect of the pounding coupling SSI on a Reinforced Concrete Frame Structure system constructed on different soil fields. Adjacent buildings with unequal height, including a 9-storey and a 3-storey reinforced concrete structure, were considered in numerical studies. Pounding force response, time-history and root-mean-square (RMS) of displacement and acceleration with different types of soil and separations were presented. The numerical results indicate that insufficient separation could lead to collisions and generate severe pounding force which could result in acceleration and displacement amplifications. SSI has significant influence of the seismic response of the structures, and higher pounding force were induced by floors with stiffer soil. SSI is reasonable neglected for a structure with a dense soil foundation, whereas SSI should be taken into consideration for dynamic analysis, especially for soft soil base.

Moment ratio considering composite beam action for steel special moment frames

  • Sang Whan Han;Soo Ik Cho;Taeo Kim;Kihak Lee
    • Steel and Composite Structures
    • /
    • v.47 no.4
    • /
    • pp.489-502
    • /
    • 2023
  • The strong column-weak beam (SCWB) moment ratio is specified in AISC 341 to prevent an abrupt column sway in steel special moment frames (SMFs) during earthquakes. Even when the SCWB requirement is satisfied for an SMF, a column-sway can develop in the SMF. This is because the contribution of the composite beam action developed in the concrete floor slab and its supporting beams was not included while calculating the SCWB moment ratio. In this study, we developed a new method for calculating the SCWB moment ratio that included the contribution of composite beam action. We evaluated the seismic collapse performance of the SMFs considering various risk categories and building heights. We demonstrated that the collapse performance of the SMFs was significantly improved by using the proposed SCWB equation that also satisfied the target performance specified in ASCE 7.

Influence of roadside buildings on the noise in the backside blocks in city area (도시내 가로변 빌딩이 도로 이면지역의 소음에 미치는 영향)

  • Kim, Yong-Seong;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.352-362
    • /
    • 2019
  • The old residences and shops in the backside blocks are affected by the traffic noises from the main road. The noise of the backside roads is affected by the following factors such as the height of the roadside buildings, the distance between the road and the backside streets, distance among adjacent roadside buildings, and the difference of the adjacent building heights. The both noise levels on the road and the backside street were measured simultaneously in 15 urban blocks of a city which can be categorized into two types of roadside building plans ; 1) one single building along the street, 2) buildings arranged on one axis beside the road. As the results, there is no significant noise reduction due to the width of the buildings in general. However, in the cases of buildings arranged on one axis beside the road, it was found that the average noise reduction was 12 dB(A) on the basis of the building height of 4 m. Also, it was analysed that for each 4 m increase in the building height, noise reduction occurred by 2 dB(A) beyond building height of 4 m. In general, it was proved that the noise of the back streets is mainly affected by the lowest height of the roadside buildings. It was found that noise is increased by 1 dB(A) for each 4 m increase of the height difference between adjacent buildings. Also, It was revealed that for each 0.5 m increase in the distance between roadside building, noise reduction decreased by 1 dB(A).

Soil arching analysis in embankments on soft clays reinforced by stone columns

  • Fattah, Mohammed Y.;Zabar, Bushra S.;Hassan, Hanan A.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.507-534
    • /
    • 2015
  • The present work investigates the behavior of the embankment models resting on soft soil reinforced with ordinary and stone columns encased with geogrid. Model tests were performed with different spacing distances between stone columns and two lengths to diameter ratios (L/d) of the stone columns, in addition to different embankment heights. A total number of 42 model tests were carried out on a soil with undrianed shear strength $${\sim_\sim}10kPa$$. The models consist of stone columns embankment at s/d equal to 2.5, 3 and 4 with L/d ratio equal 5 and 8. Three embankment heights; 200 mm, 250 mm and 300 mm were tested for both tests of ordinary (OSC) and geogrid encased stone columns (ESC). Three earth pressure cells were used to measure directly the vertical effective stress on column at the top of the middle stone column under the center line of embankment and on the edge stone column for all models while the third cell was placed at the base of embankment between two columns to measure the vertical effective stress in soft soil directly. The performance of stone columns embankments relies upon the ability of the granular embankment material to arch over the 'gaps' between the stone columns spacing. The results showed that the ratio of the embankment height to the clear spacing between columns (h/s-d) is a key parameter. It is found that (h/s-d)<1.2 and 1.4 for OSC and ESC, respectively; (h is the embankment height, s is the spacing between columns and d is the diameter of stone columns), no effect of arching is pronounced, the settlement at the surface of the embankment is very large, and the stress acting on the subsoil is virtually unmodified from the nominal overburden stress. When $(h/s-d){\geq}2.2$ for OSC and ESC respectively, full arching will occur and minimum stress on subsoil between stone columns will act, so the range of critical embankment height will be 1.2 (h/sd) to 2.2 (h/s-d) for both OSC and ESC models.

Inter-story pounding between multistory reinforced concrete structures

  • Karayannis, Chris G.;Favvata, Maria J.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.5
    • /
    • pp.505-526
    • /
    • 2005
  • The influence of the inter-story structural pounding on the seismic behaviour of adjacent multistory reinforced concrete structures with unequal total heights and different story heights is investigated. Although inter-story pounding is a common case in practice, it has not been studied before in the literature as far as the authors are aware. Fifty two pounding cases, each one for two different seismic excitations, are examined. From the results it can be deduced that: (i) The most important issue in the inter-story pounding is the local effect on the external column of the tall building that suffers the impact from the upper floor slab of the adjacent shorter structure. (ii) The ductility demands for this column are increased comparing with the ones without the pounding effect. In the cases that the two buildings are in contact these demands appear to be critical since they are higher than the available ductility values. In the cases that there is a small distance between the interacting buildings the ductility demands of this column are also higher than the ones of the same column without the pounding effect but they appear to be lower than the available ductility values. (iii) It has to be stressed that in all the examined cases the developed shear forces of this column exceeded the shear strength. Thus, it can be concluded that in inter-story pounding cases the column that suffers the impact is always in a critical condition due to shear action and, furthermore, in the cases that the two structures are in contact from the beginning this column appears to be critical due to high ductility demands as well. The consequences of the impact can be very severe for the integrity of the column and may be a primary cause for the initiation of the collapse of the structure. This means that special measures have to be taken in the design process first for the critically increased shear demands and secondly for the high ductility demands.

Building Change Detection Methodology in Urban Area from Single Satellite Image (단일위성영상 기반 도심지 건물변화탐지 방안)

  • Seunghee Kim;Taejung Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_4
    • /
    • pp.1097-1109
    • /
    • 2023
  • Urban is an area where small-scale changes to individual buildings occur frequently. An existing urban building database requires periodic updating to increase its usability. However, there are limitations in data collection for building changes over a wide urban. In this study, we check the possibility of detecting building changes and updating a building database by using satellite images that can capture a wide urban region by a single image. For this purpose, building areas in a satellite image are first extracted by projecting 3D coordinates of building corners available in a building database onto the image. Building areas are then divided into roof and facade areas. By comparing textures of the roof areas projected, building changes such as height change or building removal can be detected. New height values are estimated by adjusting building heights until projected roofs align to actual roofs observed in the image. If the projected image appeared in the image while no building is observed, it corresponds to a demolished building. By checking buildings in the original image whose roofs and facades areas are not projected, new buildings are identified. Based on these results, the building database is updated by the three categories of height update, building deletion, or new building creation. This method was tested with a KOMPSAT-3A image over Incheon Metropolitan City and Incheon building database available in public. Building change detection and building database update was carried out. Updated building corners were then projected to another KOMPSAT-3 image. It was confirmed that building areas projected by updated building information agreed with actual buildings in the image very well. Through this study, the possibility of semi-automatic building change detection and building database update based on single satellite image was confirmed. In the future, follow-up research is needed on technology to enhance computational automation of the proposed method.

Near-ground wind and its characterization for engineering applications

  • Crandell, Jay H.;Farkas, William;Lyons, James M.;Freeborne, William
    • Wind and Structures
    • /
    • v.3 no.3
    • /
    • pp.143-158
    • /
    • 2000
  • This report presents the findings of a one-year monitoring effort to empirically characterize and evaluate the nature of near-ground winds for structural engineering purposes. The current wind engineering practice in the United States does not explicitly consider certain important near-ground wind characteristics in typical rough terrain conditions and the possible effect on efficient design of low-rise structures, such as homes and other light-frame buildings that comprise most of the building population. Therefore, near ground wind data was collected for the purpose of comparing actual near-ground wind characteristics to the current U.S. wind engineering practice. The study provides data depicting variability of wind speeds, wind velocity profiles for a major thunderstorm event and a northeaster, and the influence of thunderstorms on annual extreme wind speeds at various heights above ground in a typical rough environment. Data showing the decrease in the power law exponent with increasing wind speed is also presented. It is demonstrated that near-ground wind speeds (i.e., less than 10 m above ground) are likely to be over-estimated in the current design practice by as much as 20 percent which may result in wind load over-estimate of about 50% for low-rise buildings in typical rough terrain. The importance of thunderstorm wind profiles on determination of design wind speeds and building loads (particularly for buildings substantially taller than 10 m) is also discussed. Recommendations are given for possible improvements to the current design practice in the United States with respect to low-rise buildings in rough terrain and for the need to study the impact of thunderstorm gust profile shapes on extreme value wind speed estimates and building loads.

Comparison on Flexural Behaviors of Architectural Precast Prestressed Rectangular and Inverted-tee Concrete Beams (건축용 프리캐스트 프리스트레스트 역티형 보와 직사각형 보의 휨거동 비교)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.75-82
    • /
    • 2000
  • Flexural behaviors of two typical architectural precast beam sections ; inverted tee and rectangular - were compared and investigated. The heights of web in inverted tee beams are generally less than half of beam depth in building structures to accomodate the nib of double-tee where the total building height limited considerably. The inverted-tee beams are designed for parking live load - 500kgf/$\m^2$ and market - 1,200kgf/$\m^2$ according to the currently used typical shape in the domestic market building site in Korea. The bottom dimension and area of rectangular beams are same to those of inverted tee beams to compare the flexural behaviors of two beams. These two beams are also reinforced for similar strength. Four flexural tests are performed on two beams. Following results are obtained from the tests; 1) The rectangular beam is simpler in production, transportation, and election, and more economic than the inverted tee beam for these two beams with same dimension and similar strength. 1) The estimations of flexural strength of two beams by Strength Design Method and Strain Compatibility Method is fully complied with the result of tests. However, Strain Compatibility Method is slightly ore accurate than Strength Design Method. 2) Overall deflections of two type beam under the service loads are less than those of the allowable limit in ACI Code provision. 3) The rectangular beam is failed in large deflection (average 12.56mm large) than those of inverted tee beams. 4) The rectangular and inverted tee beams with 6m span develop initial flexural crackings under the 88% of full service loading even though they designed to satisfy the ACI tensile stress limit provisions.

A Study on the Front Elevation Proportion System in Traditional Housing 'An-Chae' - Focused on the Middle-High Classes' Housing in Jeonnam District - (전통주거안채의 정면비례체계에 관한 연구 - 전남지방 중.상류 주택을 중심으로 -)

  • Park, Ji-Min;Cheon, Deuk-Youm
    • Journal of architectural history
    • /
    • v.14 no.4 s.44
    • /
    • pp.73-86
    • /
    • 2005
  • The purpose of this study is to prove the correlations among various factors what determined to formation of front elevation proportion system through making an actual survey and investigating. According to the analysis of them, we make conclusions as follows; 1, On the assumption that average distance of 1Kan(間) is 1, the height of foundation is 0.21, the height of floor from foundation is 0.24, the height of normal column from floor is 0.85, the height of eaves from foundation is 1.10. 2. Southeast faced buildings are wider than southwest faced buildings in the distance of 1Kan (間) in the range of $110{sim}220mm$. The height of foundation and floor in the southeast faced buildings are higher than those in southwest faced buildings beside the height of normal column, eaves, high column in the southwest faced buildings are higher than those in southeast faced buildings. 3. As number of front Kan(間) increases, the distance of 1Kan(間) decrease and the height of eaves and high column(高柱) increases. This is cause of making a maximum needed inner space by increasing the distance of 1Kan(間). This is an wisdom for living from ancestors. 4. As number of Dori(道里) increases, the distances of 1Kan are nearly same but the height of eaves and high column(高柱) increases about 300mm, This is a natural result from an increasing of building scale. 5. The distance of 1Kan(間) in later 19C building is most wide but, the unit heights are minimal average values at year 1900 as a reference mark. After this, the height of normal column, eaves, high column are higher about $170{sim}330mm$. 6. The number of Kan in front elevation, Dori(道里), and direction of building have correlations each other in proportion system of traditional housing An-Chae with significant level, p<0.05.

  • PDF

A Study on the Reproduction of 3-Dimensional Building Model from Single High Resolution Image without Meta Information (메타정보 없는 단일 고해상도 영상으로부터 3차원 건물 모델 생성에 관한 연구)

  • Lee, Tae-Yoon;Kim, Tae-Jung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.3
    • /
    • pp.71-79
    • /
    • 2009
  • We expanded the 3D building information extraction method using shadow and vertical line from single high resolution image with meta information into the method for single high resolution image without meta information. Our method guesses an azimuth angle and an elevation angle of the sensor and the sun using reference building, selected by user, on an image. For test, we used an IKONOS image and an image extracted from the Google Earth. We calculated the Root Mean Square (RMS) error of heights extracted by our method using the building height extracted from stereo IKONOS image as reference, and the RMS error from the IKONOS image and the Google Earth image was under than 3 m. We also calculated the RMS error of horizontality position by comparison between building position extracted from only the IKONOS image and it from 1:1,000 digital map, and the result was under than 3 m. This test results showed that the height pattern of building models by our method was similar with it by the method using meta information.

  • PDF