• Title/Summary/Keyword: Building Facades

Search Result 81, Processing Time 0.023 seconds

Cooling Energy Saving System using Solar Heat Protection Dvices (일사차단용 설비를 이용한 냉방 에너지 절약 방안)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

Development of analytical modeling for an energy-dissipating cladding panel

  • Maneetes, H.;Memari, A.M.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.5
    • /
    • pp.587-608
    • /
    • 2009
  • Modern earthquake-resistant design aims to isolate architectural precast concrete panels from the structural system so as to reduce the interaction with the supporting structure and hence minimize damage. The present study seeks to maximize the cladding-structure interaction by developing an energy-dissipating cladding system (EDCS) that is capable of functioning both as a structural brace, as well as a source of energy dissipation. The EDCS is designed to provide added stiffness and damping to buildings with steel moment resisting frames with the goal of favorably modifying the building response to earthquake-induced forces without demanding any inelastic action and ductility from the basic lateral force resisting system. Because many modern building facades typically have continuous and large openings on top of the precast cladding panels at each floor level for window system, the present study focuses on spandrel type precast concrete cladding panel. The preliminary design of the EDCS was based on existing guidelines and research data on architectural precast concrete cladding and supplemental energy dissipation devices. For the component-level study, the preliminary design was validated and further refined based on the results of nonlinear finite element analyses. The stiffness and strength characteristics of the EDCS were established from a series of nonlinear finite element analyses and are discussed in detail in this paper.

Multi-Dimensional Hybrid Design and Construction of Skyscraper Cluster -Innovative Engineering of Raffles City Chongqing-

  • Wang, Aaron J.
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.261-269
    • /
    • 2017
  • Designed by star architect of Moshes Safdie, Raffles City Chongqing includes a total of 6 mega high-rise towers 250 to 380 m tall, a sky conservatory, a 5-storey high shopping mall and a 3-storey basement car parking. Located at the confluence of the Yangtze and Jailing Rivers, the site for the project is imbued with a significance that is immediately symbolic, both as a sign of Chongqing's important past and as a vivid indicator of the city's thriving present and future. The design for the project to be situated at this gateway takes as its governing idea the image of powerful sails upon the water. The outer facades of the project's eight towers - the transparent surfaces that will face the water to the north - are meant to recall a fleet of ancient Chinese ships, with their huge rectangles of white canvas filled by the wind. This is a $1.13million\;m^2$ mega scale integrated project of office, retail, hotel, service residence and high-end residence with the transportation hub and traffic circulation at various levels of the project. This paper presents the multi-dimensional hybrid design, engineering and construction of this mega scale project. The innovations and the cutting-edge technology used in this project are introduced and discussed benchmarking the design and construction of the skyscraper cluster in a major city like Chongqing of China.

A Study on cognition Characteristics about the Landscape in Apartments at the Street - Focused on Apartments in Namak Newtown - (가로변 공동주택 경관의 인지 특성에 관한 연구 - 남악신도시 공동주택을 대상으로 -)

  • Lee, Jae-Min;Kim, Yun-hag
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.2
    • /
    • pp.9-21
    • /
    • 2011
  • This study aims to examine and research the characteristics of apartment landscape at the street from a view that apartments are the major element of a cityscape and many apartments form a street today. Then, the subjects of this study were three sections consisting of streets in Namak New Town and the results were as follows. A streetscape is necessary to have identity under the unity(context) of parts which orient to "one as a whole". However, the subject apartments were not united(contextual) in layouts, roofs, and walls, whereas their facades appeared too united(contextual). Accordingly, to make a united(contextual) streetscape, the wall located in a boundary(a buffer zone) with public space which consists of a streetscape, building layout, building height, and roof forms need a design guideline which can have unity as a whole to connect with architectural design. On the other hand, the facade which was found too uniform should have a more active design guideline to elicit identity at unity.

An Experimental Study of Solar fir Roof Heating System With PVT Collector (공기식 집열 지붕 난방시스템의 실험 연구)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF

Extraction of Three-Dimensional Hybrid City Model based on Airborne LiDAR and GIS Data for Transportation Noise Mapping (교통소음지도 작성을 위한 3차원 도시모델 구축 : 항공 LiDAR와 GIS DB의 혼용 기반)

  • Park, Taeho;Chun, Bumseok;Chang, Seo Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.933-938
    • /
    • 2014
  • The combined method utilizing airborne LiDAR and GIS data is suggested to extract 3-dimensional hybrid city model including roads and buildings. Combining the two types of data is more efficient to estimate the elevations of various types of roads and buildings than using either LiDAR or GIS data only. This method is particularly useful to model the overlapped roads around the so called spaghetti junction. The preliminary model is constructed from the LiDAR data, which can give wrong information around the overlapped parts. And then, the erratic vertex points are detected by imposing maximum vertical grade allowable on the elevated roads. For the purpose of efficiency, the erratic vertex points are corrected through linear interpolation method. To avoid the erratic treatment of the LiDAR data on the facades of buildings 2 meter inner-buffer zone is proposed to efficiently estimate the height of a building. It is validated by the mean value (=5.1%) of differences between estimated elevations on 2 m inner buffer zone and randomly observed building elevations.

  • PDF

Fashion retail store facades and the creation of store image and store attitude (파사드가 의류브랜드 점포이미지와 점포태도에 미치는 영향)

  • Seo, Joo-Hyun;Lee, Kyu-Hye
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.3
    • /
    • pp.400-411
    • /
    • 2015
  • Successful use of displays in stores arouses consumers' curiosity, and induces them to purchase a product after a visit. Facade is a word meaning an external front wall of a building, and is usually the first point of visual contact for the consumers. The present study is an empirical investigation of external appearance of a clothing store, with a $2{\times}2{\times}2$ factorial design of facade, show window, and wall surface material designed for the purpose of the study. Dependent variables were store image variables and attitude toward store. A total of 320 questionnaires from male and female consumers were used for the analysis. Facade type and material had significant main and interaction effects, while show window type had no meaningful effects overall. A facade of irregular design prompted significantly higher levels of perceived 'elegance', 'uniqueness', and 'attractiveness' of the store. Material itself did not have significant influence but did have significant interaction effect with facade design. The interaction effect was found in store attitude as well. In order to create a positive store attitude, a concrete material facade should have an irregular design. Companies owning fashion brands should carefully select facade type and wall surface material in the visual merchandising strategies of a store.

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

A Study on Non-western modernity of Surface Phenomena in Korean Commercial Architecture (한국 상업건축 입면현상의 비서구적 근대성에 대한 연구)

  • Lee, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.218-227
    • /
    • 2011
  • Korean commercial architecture is based on two distinctive characteristics of western modern architecture: grid frame structure and free facade. However, the original facade of the building disappears as numbers of commercial advertisements and signboards representing inner programs cover up the original facade. This is a unique feature of commercial architecture in Korea which I would call the surface phenomena of Korean commercial architecture. Common criticism on this type of building is that too many and too big signboards infringe upon the original pure facade of the architecture. Underlying assumption here is that signboards and commercial ads are inessential and decorative elements simply attached to the original pure facade of modern architecture. However, in this paper, I argue that commercial decorations is an essential aspect of korean commercial architecture rather than an inessential decorative element attached later to the essential facade of architecture and that it reflects the historical specificity of cultural and architectural modernity of Korea And thus, the surface phenomena of Korean commercial architecture should not be judged based upon the aesthetic paradigms of either western modern or postmodern architecture. Rather, it can be argued that surface phenomena of Korean commercial architecture is a reflection of a modernity beyond the paradigm of western modernism and postmodernism. The agenda of Korean commercial architecture is then not simply to restrict or to control signboards on the building facades with the intention to clean up facade of the building but rather to integrate the signs and commercial ads with the structure of architectural surface.

Measurement and Evaluation of the Acoustic Performance in the Royal Palace Buildings of Joseon Dynasty - Focused on Pyeonjeon and Chimjeon - (조선 궁궐 건축물의 음향성능 측정 및 평가 - 편전 및 침전을 중심으로 -)

  • Kim, Nam-Wook;Kim, Myung-Jun;Han, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1269-1280
    • /
    • 2009
  • This study was performed to construct sound performance DB of royal palace buildings and to examine the special quality more scientifically. Research target of royal palace were Changdeokgung and Gyeongbokgung. Sound insulation performance between the adjacent room and facade, room acoustics of Pyeonjeon and Chimjeon which is representative building in royal palace were examined through field measurement. Measured values of RT($T_{mf}$) at Pyeonjeon were 0.78 sec. and 1.03 sec. in Seonjeongjoen and Sajeongjoen, respectively. The RTs of both Pyeonjeon buildings were estimated suitable for speech and lecture considering their volume. The RT($T_{mf}$)s at Chimjeon were measured in range of 0.29~0.55 sec. This meant that the acoustic energy in rooms was decreased by sound transmission through mulberry paper(Hanji) of traditional windows and doors. As a sound insulation performance, the single-number quantities($D_{ls,2m,nT,w}$) of the building facades in Pyeonjeon and Chimjeon were measured 4~20 dB. Also the single-number quantities($D_{p,w}$) between the adjacent rooms in Chimjeon were measured 3~18 dB. Sound insulation performance of traditional building elements such as window and door depended strongly on their layers and area.