• Title/Summary/Keyword: Building External

Search Result 824, Processing Time 0.028 seconds

An Analytic Study on Structural Stability according to Boundary Conditions and H-section Column Lengths Made of An Ordinary Grade Structural Steels (SS 400) at High Temperatures (일반구조용 강재(SS 400)기둥부재의 경계조건과 부재 길이변화에 따른 고온 내력의 해석적 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • Steel column is very important an structural element in steel framed building and plays a key role in sustataining the applied external load. Generally, the fire resistance performance of steel column has been executed by application of fire standard and vertical furnace having a limitation in height. Therefore, the fire resistance test was conducted with a H-section column having 3500 mm in length and hinge to hinge boundary condition. And the fire protective material derived from the fire test can be applied to any kind of boundary conditions and lengths. However, it is hard to determine the fire resistance. In this paper, to make sure the structural stability of them at high temperature according to various boundary conditions and lengths of H-section column, an analysis was done by using the mechanical properties and an heat transfer theory.

A Study on Revitalization of Library Service for the Alienated Class (정보취약계층을 위한 도서관 서비스 활성화 방안에 관한 연구)

  • Nam, Young-Joon
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.41 no.4
    • /
    • pp.49-68
    • /
    • 2007
  • To promote information service and to encourage active participation from the group categorized as the alienated class(group of people) this study suggests the basic concepts and strategy for the information services to alienated class who does not have full public library services. The paper classifies three separate groups of alienated groups, handicapped. poor(economically unfortunate group) and elderly group. The service shall consider their needs from their own Point of concern and interests. There are three distinctive considerations, infra structure(facility building, space. place). administrative consideration, and equipments. Infra-structure includes the planning of the space to facilitate the equipments and reference materials which will be control)ed and moderated by a librarian. Administrative service includes the development for the educational system between the end users and external experts. It also includes the individualized education system for each group Material and equipment consideration should include the each group's specific needs such as the infra-structures which is provided for the handicapped person.

Development of Hypertension Predictive Model (고혈압 발생 예측 모형 개발)

  • Yong, Wang-Sik;Park, Il-Su;Kang, Sung-Hong;Kim, Won-Joong;Kim, Kong-Hyun;Kim, Kwang-Kee;Park, No-Yai
    • Korean Journal of Health Education and Promotion
    • /
    • v.23 no.4
    • /
    • pp.13-28
    • /
    • 2006
  • Objectives: This study used the characteristics of the knowledge discovery and data mining algorithms to develop hypertension predictive model for hypertension management using the Korea National Health Insurance Corporation database(the insureds' screening and health care benefit data). Methods: This study validated the predictive power of data mining algorithms by comparing the performance of logistic regression, decision tree, and ensemble technique. On the basis of internal and external validation, it was found that the model performance of logistic regression method was the best among the above three techniques. Results: Major results of logistic regression analysis suggested that the probability of hypertension was: - lower for the female(compared with the male)(OR=0.834) - higher for the persons whose ages were 60 or above(compared with below 40)(OR=4.628) - higher for obese persons(compared with normal persons)(OR= 2.103) - higher for the persons with high level of glucose(compared with normal persons)(OR=1.086) - higher for the persons who had family history of hypertension(compared with the persons who had not)(OR=1.512) - higher for the persons who periodically drank alcohol(compared with the persons who did not)$(OR=1.037{\sim}1.291)$ Conclusions: This study produced several factors affecting the outbreak of hypertension using screening. It is considered to be a contributing factor towards the nation's building of a Hypertension Management System in the near future by bringing forth representative results on the rise and care of hypertension.

A Control Room Dose Assessment for a 1300 MWe PWR Following a Loss of Coolant Accident (냉각재(冷却材) 상실사고시(喪失事故時) 1300 MWe 급(級) PWR원전(原電) 주제어실(主制御室)의 선량평가(線量評價))

  • Chang, Si-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.34-45
    • /
    • 1989
  • The habitability of a reactor control room in a French 1300 MWe P'4 type PWR has been evaluated through the exposure dose assessment for the reactor operator following a Loss of Coolant Accident. The main hypotheses adopted in this evaluation are based on the French Standard Safety Analysis Report. A simple computer program, named COREX(Control Room EXposure), was developed to calculate : the time-integrated radioactivities released from the reactor building, the volume factors for radionuclides concerned and the resulting time-integrated external whole body and internal thyroid doses to the reactor operators staying in the control room up to 30 days following the LOCA. The results obtained in this study, on the whole, well agreed with those proposed by the EDF(Electricite de France) except for the case of the whole body exposure, which was attributed to the differences in the volume factors for the radionuclides concerned.

  • PDF

A Study on the Condensation Performance of The Curtain-walls (커튼월 결로 성능평가에 관한 연구)

  • Lee, Sang-Jin;Ock, Jong-Ho;Kim, Sung-Keun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.808-812
    • /
    • 2008
  • Recently, the buildings have been likely to shape Super Tall trend. Therefore, the exterior parts of the buildings come to be changed. Instead of early heavy wall structure, it is changed to light wall concept of curtain wall system. However, the curtain wall system causes lots of loads due to the external surrounding factors of building. In particular, due to the densely built-up condition in Korea, the generation of dew condensation is getting severer Since there has been no standardized process that reviews this generation of dew condensation, it is very urgent for us to prepare the reviewing process for the dew condensation for construction business managers. The purpose of this study is to assess dew condensation function of the curtain wall and provide the basic data for the provision of the future dew condensation review process by comparing and analyzing the range of generation of dew condensation as well as temperature distribution according to the change of relative humidity at the identical temperature by selecting the Unitized system and Stick system which are the representative types of curtain wall system.

  • PDF

An Experimental Study on Individual Difference in Reaction to Mild Environment in Adult Males - On the Perspective of Sasang Constitution (온열 환경 반응에 대한 사상체질간 차이에 대한 실험적 연구)

  • Kim Seon-Ho;Lee Eun-Seon;Kim Ji-Eun;Park Kyung-Mo;Lee Ju-Youn;Choi Ho-Seon
    • The Journal of Korean Medicine
    • /
    • v.26 no.1 s.61
    • /
    • pp.123-133
    • /
    • 2005
  • Objective : We investigated the sasang constitutional difference of physiological and psychological response in various thermal environmental conditions. Methods: Among 210 volunteers, 30 healthy subjects were selected through the QSCC II (a questionnaire for constitutional discrimination) and the manual examination of a specialist in sasang constitution. Subjects consisted of 10 each Soyang(少陽), Soeum(少陰), and Taeum(太陽). Experimental environments were set by six different conditions to be $23^{\circ}C,\;50\%\;RH,\;0.lm/s;\;25^{\circ}C,\;25\%\;RH,\;0.lm/s;\;25^{\circ}C,\;50\%\;RH,\;0.lm/s;\;25^{\circ}C,\;50\%\;RH,\;0.4m/s;\;25^{\circ}C,\;75\%\;RH,\;0.1m/s;\;and\;27^{\circ}C,\;50\%\;RH,\;0.1m\s$ (respectively temperature, relative humidity, and wind velocity). Skin temperature, core temperature, heart rate variability (HRV), and galvanic skin response (GSR) were measured for each subject Additionally, subjects were asked about comfort through the questionnaire. Results: From the viewpoint of external temperature sensibility, in all experimental environments, generally the Taeum type feels hotter and the Soeum feels colder than other types. In relative comfort, Soeum types were most sensitive to wind velocity change. From the viewpoint of body temperature, Taeum type was lower and Soyang was higher than other types. The measurements of HRV and GSR showed no difference between the types. Conclusion : The four sasang constitution types showed different responses to various thermal environmental conditions. Accordingly, our research could provide basic data for building the optimal thermal conditions for individuals based on sasang constitution. Consequently, it will help to build a healthy environment for everyday life.

  • PDF

An Experimental Study on the Automatic Interlinking of Meaning for the LOD Construction of Record Information (기록정보 LOD 구축을 위한 의미 상호연결 자동화 실험 연구)

  • Ha, Seung-rok;An, Dae-Jin;Yim, Jin-hee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.17 no.4
    • /
    • pp.177-200
    • /
    • 2017
  • In a new technological environment such as big data and AI, LOD will link record information resources with various data from both inside and outside. At the heart of this connection is the interlinking technology, and interlinked LOD will realize the opening of record information as the highest level of open data. Given the ever-increasing amount of records, automation through interlinking algorithms is essential in building LODs. Therefore, this paper analyzed the structure of record information interlinking with the external data and characteristics of the record information to be considered when interconnecting. After collecting samples from the CAMS data of the National Archives, we constructed a record information's LOD. After that, we conducted a test bed that automatically interlinks the personal information of the record metadata with DBPedia. This confirms the automatic interlinking process and the performance and accuracy of the automation technology. Through the implications of the testbed, we have identified the considerations of the record information resources of the LOD interlinking process.

A Study on Course Stability in Accordance with Configuration of Ships (선형에 따른 선박의 침로 안정성에 관한 연구)

  • 권종호
    • Journal of the Korean Institute of Navigation
    • /
    • v.10 no.2
    • /
    • pp.97-114
    • /
    • 1986
  • Ship's maneuverability is very important factor in safe ship handling and economical ship operation. Steering characteristics are consisted of course stability and maneuverability. Today in many advanced ship-building countries, they study ship's course stability, using model ship tests, such as straight line tests, rotating arm tests and Planar Motion Mechanism (PMM) etc., in tow in tanks. It is the purpose of this paper to provide ship's handlers with better understanding of steering characteristics and to help them in safe controlling and manevering . In this paper, the author simulated response of various vessels, running straight course with constant speed, and they are disturbed by small external disturbance of one degree yaw angle with no angular velocity . The author used the hydrodynamic derivtives resulted at tests of Davidson's laboratory in Stevens Institute of Technology, New Jersey, U.S.A. Course stability was evaluated and analyzed in various respects, such as block coefficient, ratio of ship's length to beam, draft and rudder area ratio etc. The obtained results are as follows : (1) The ship's course stability is affected by magnitude of block coefficient greatly. In case that the block coefficient is more than 0.7, the deviation varies at nearly same rate but the requistite time to reach the steady course is different. (2) The ship's course stability is affected by magnitude of L/B. When the dimensionless time reaches about 3, the deviation and requisite time to reach the steady course are influenced nearly same. After the dimensionless time is about 3, they change on invariable ratio. (3) The effect to course stability by L/T and RA' can be neglected. (4) The reason why thy VLCC and container feeder vessel are unstable on their course is that their block coefficient is generally more than 0.8 and the ratio of ship's length to beam is about 6.0.

  • PDF

A Study on the Effect of Open and Closed Room Doors on Apartment Ventilation Characteristics (공동주택에서 각 실 문의 개폐에 따른 환기 특성 연구)

  • Choi, Im-Kyoo;Kim, Young-Il;Chung, Kwang-Seop
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.469-474
    • /
    • 2008
  • The objective of this study is to propose basic design guidelines for more effective air ventilation system in apartments. It is well known that ventilation depends on whether the room doors are open or closed as well as people's living patterns. This study considers 84 ㎡-sized apartment which has extended living room without balcony. Ventilation of bathroom and kitchen is not considered. The height of the building, external air pressure and air infiltration through the windows are also neglected. The regulation on indoor air quality made it mandatory that the air change per hour be more than 0.7. Four models are suggested to study the effect of open and closed doors. Models 1 and 3 are open door types and models 2 and 4 are closed door types. The open types have 50 mm hole near the top of the door to substitute exhaust outlet. The ventilation effectiveness was evaluated by 3-dimensional numerical simulation using finite volume method by a commercial software. This work compares air flow, temperature of air, age of air and the efficiency of ventilation of apartments with wooden doors of bedroom 1 and 2, which are open or closed.

  • PDF

A Basic Study on the Effect of the Wind Pressure according to Form on the Flat Roof mounted PV System (평지붕 PV거치 시스템의 형태에 따른 풍압영향에 관한 기초연구)

  • Yun, Doo-Young;Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.105-112
    • /
    • 2013
  • The new renewable energy became popular as a clean and sustainable alternative energy under the circumstances that the entire world is facing severe abnormal climate due to the use of fossil fuel, and among which, solar energy can be obtained anywhere and is not difficult to apply it into the existing buildings, which makes it possible to be widely distributed. However, as PV module is installed into a single plate system, it shows structural weaknesses which are vulnerable to wind load and give loss to design elements in external appearance. Accordingly, this study planned one-step parallel system to complement the problems occurring from a single plate system and used STAR-CCM+ V.8 made by CD-Adapco, a computational fluid dynamics(CFD) simulation tool to measure wind load stability and support based on the design standards for a single plate system and one-step parallel system. Building height was limited to less than 10m and wind speed was given when increasing from 35m/s to 50m/s by 5m/s on PV system installed into the flat roof. In this case, our analysis suggested that step-one parallel system was in class 7-9 according to Beaufort's wind power classification, which did not have an impact on the fixed PV system, and the single plate system is considered to cause risks in designing wind speed in central districts because it is more than wind power class 12.