• 제목/요약/키워드: Building Energy Simulation

검색결과 681건 처리시간 0.028초

Seismic performance of a 10-story RC box-type wall building structure

  • Hwang, Kyung Ran;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1193-1219
    • /
    • 2015
  • The purpose of this study is to evaluate the seismic performance of high-rise reinforced concrete (RC) box-type wall structures commonly used for most residential buildings in Korea. For this purpose, an analytical model was calibrated with the results of the earthquake simulation tests on a 1:5 scale 10-story distorted model. This calibrated model was then transformed to a true model. The performance of the true model in terms of the stiffness, strength, and damage distribution through inelastic energy dissipation was observed with reference to the earthquake simulation test results. The model showed high overstrength factors ranging from 3 to 4. The existence of slab in this box-type wall system changed the main resistance mode in the wall from bending moment to tension/compression coupled moment through membrane actions, and increased the overall resistance capacity by about 25~35%, in comparison with the common design practice of neglecting the slab's existence. The flexibility of foundation, which is also commonly neglected in the engineering design, contributes to 30~50% of the roof drift in the stiff direction containing many walls. The possibility of concrete spalling and reinforcement buckling and fracture under the maximum considered earthquake (MCE) in Korea appears to be very low when compared with the case of the 2010 Concepcion, Chile earthquake.

3차원 Web GIS 기반 풍력에너지 시설물 적지분석 시스템 개발 (Development of a Suitability Analysis System for Wind Energy Facilities Using 3D Web GIS)

  • 김광득;윤창열;조명희;김성재
    • 한국지리정보학회지
    • /
    • 제15권3호
    • /
    • pp.81-90
    • /
    • 2012
  • 최근 신재생에너지 자원에 대한 사회적인 관심 증대와 맞물려 IT(Information Technology) 기술과 공간정보기술의 급속한 발전에 따라 신재생에너지 분야에서도 GIS(Geographic Information System) 공간정보 분석 기술과의 융합을 통하여 체계적이고 과학적인 활용 방법들이 많이 연구되고 있다. 본 연구에서는 정확한 지형, 경제, 문화적 환경 요소들을 종합적으로 고려한 정확하고 정밀한 풍력에너지 시설물 적지분석 시스템 모듈 개발과 동시에 3차원 GIS 등과 같은 최신 공간 정보기술을 활용하여 정밀한 현장정보 구현과 3차원 결과물 표출, 3차원 객체 구현, 모의 등 풍력 신재생에너지 관련 종합정보를 관리할 수 있는 3차원 Web GIS 기반 풍력에너지 시설물 적지분석 시스템을 개발하였다. 이를 통하여 과학적인 신재생에너지 시설물 단지 조성과 함께 정확하고 정량적인 정보 수집, 관리, 분석이 가능할 뿐만 아니라 실시간 정보제공체계 구축의 전환점을 마련할 수 있었으며 3차원 영상기반 신재생에너지 자원정보 관리시스템 구축을 통한 다양한 현장정보 분석이 가능함으로써 합리적 의사결정 지원을 할 수 있게 되었다.

지열을 이용한 공조외기부하저감(空調外氣負荷低減)시스템의 설계 및 도입 효과에 관한 연구 -실측결과 및 열성능 예측을 위한 수치모델의 제안- (Study on Designing and Installation Effect of Fresh Air Load Reduction by using Underground Double Floor Space-Experimental Result and Proposal of Numerical Model for Thermal Performance-)

  • 손원득;최영식
    • 한국산업융합학회 논문집
    • /
    • 제7권3호
    • /
    • pp.233-240
    • /
    • 2004
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space The system was introduced into a real building and was examined by the field measurement Judging from the measurements during three years(1999~2001), the state of the system operation was very stable through this period and it was clear that the system contributes to reduction of energy consumption for air-conditioning. Futhermore, a simulation model used the simple heat diffusion equation Was developed to simulate its thermal characteristics and performances The simulations resulted m air temperature in good agreement with the measurements. Also, from the result of numerical analysis, It is clear that the amount of heat supply by using this system is more than the amount of energy loss to the room above it. Therefore, it is concluded that this systems is very useful and the proposed numerical model can be used for the prediction of system thermal performance.

  • PDF

배터리 에너지 저장 장치를 위한 2단 DC-DC-AC 컨버터의 모델링 방법 (Modeling and Control of a Two-Stage DC-DC-AC Converter for Battery Energy Storage System)

  • 현동엽;정석언;현동석
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.422-430
    • /
    • 2014
  • This study proposes a small-signal model and control design for a two-stage DC-DC-AC converter to investigate its dynamic characteristics in relation to battery energy storage system. When the circuit analysis of the two-stage DC-DC-AC converter is attempted simultaneously, the mathematical procedure of deriving the dynamic equation is complex and difficult. The main idea of modeling the two-stage DC-DC-AC converter states that this topology is separated into a bidirectional DC-DC converter and a single-phase inverter with an equivalent current source corresponding to that of the inverter or converter. The dynamic equations for the separated converter and inverter are then derived using the state-space averaging technique. The procedures of building the small-signal model of the two-stage DC-DC-AC converter are described in detail. Based on the derived small-signal model, the individual controllers are designed through a frequency-domain analysis. The simulation and experimental results verify the validity of the proposed modeling approach and controller design.

표준기상데이터 작성 시 누락된 풍속 데이터의 보간 방법 제안 (A Proposal of an Interpolation Method of Missing Wind Velocity Data in Writing a Typical Weather Data)

  • 박소우;김주욱;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.79-91
    • /
    • 2017
  • The meteorological data of 1 hour interval are required to write a typical weather data for building energy simulation. However, many meterological data are missing and the interpolation method to recover the missing data is required. Especially, lots of meterological data are replicated by linear interpolation method because the changes are not significant. While, the wind velocity fluctuates with the time or locations, so linear interpolation method is not appropriate in interpolation of the wind velocity data. In this study, three interpolation methods, using surrounding wind velocity data, Inverse Distance Weighting (IDW), Revised Inverse Distance Weighting (IDW-r), were analyzed considering the characteristics of wind velocity. The Revised Inverse Distance Weighting method, proposed in this study, showed the highest reliability in restoration of the wind velocity data among the analyzed methods.

RETScreen 모델이용 태양열온수시스템 초기설계단계 설계용량 최적화기법의 TRNSYS 모델과의 비교분석 (Comparative Study on Size Optimization of a Solar Water Heating System in the Early Design Phase Using a RETScreen Model with TRNSYS Model Optimization)

  • 이경호
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.693-699
    • /
    • 2013
  • This paper describes a method for size optimization of the major design variables for solar water heating systems at the stage of concept design. The widely used RETScreen simulation tool was used for optimization. Currently, the RETScreen tool itself does not provide a function for optimization of the design parameters. In this study, an optimizer was combined with the software. A comparative study was performed to evaluate the RETScreen-based approach with the case study of a solar heating system in an office building. The optimized results using the RETScreen model were compared to previously published results with the TRNSYS model. The objective function of the optimization is the life-cycle cost of the system. The optimized design results from the RETScreen model showed good agreement with the optimized TRNSYS results for the solar collector area and storage volume, but presented a slight difference for the collector slope angle in terms of the converged direction of the solutions. The energy cost, life-cycle cost, and thermal performance regarding collector efficiency, system efficiency, and solar fraction were compared as well, and the RETScreen model showed good agreement with the TRNSYS model for the conditions of the base case and optimized design.

복합열원설비 운전온도 최적 설정에 관한 해석적 연구 (An Analytical Study on the Optimal Set-point of the Hybrid Plant)

  • 전종욱;이선일;이태원;김용기;홍대희;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.352-357
    • /
    • 2007
  • The objective of this study is to find the optimal set-point of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Ground Source Heat Pump) and the conventional plant(chiller, boiler). The work presented in this study was carried out by using the EnergyPlus(Version 2.0). In order to validate the simulation model, field data were measured from a building. The GSHP was used as a base plant and the conventional plant as the assistant plant. Various temperatures were controlled (zone summer set-point, zone winter set-point, chilled water temperature, hot water temperature) to find the optimal set-point temperature of the system. The influence of the various set-points were analyzed seasonally.

  • PDF

설계 초기단계용 창호 열성능 및 경제성 평가 프로그램 개발 (Software Development on a Thermal Performance Evaluation and Economic Analysis of Window System for an Early Design Stage)

  • 윤종호;박재완;김효중;이철성;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.24-31
    • /
    • 2009
  • The aim of this study is to develop a software tool of thermal performance and economic analysis of windows, called WEPTools which helps architects, builders, and engineers quickly identify the most cost-effective window system in the very early stages of the design process. This software is suitable for examining middle or Large-sized commercial and residential buildings that are characterized by one thermal zone. To establish the reliability of the simulation results, we adopt TRNSYS algorithm of which verification has already well approved. Therefore it performs whole-building energy analysis for 8760 hours/year, including dynamic thermal calculation.

밀폐형 수배관시스템에서 CFD를 활용한 복합밸브 특성곡선 해석 방법 제안 (Proposal of Analyis Method for PICV Characteristics Curve Using CFD in Hydronic System)

  • 도가현;김진호;박우평;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.20-29
    • /
    • 2021
  • In this study, it is proposed that an analysis method using charatersistics curve of PICV in the CFD simulation for hydronic system. From the results, the pressure drop characteristics appeared in the region of PICV at a specified flow rate. And the CFD results are in good agreement with the experimental results. Proposed analysis method is proved that the characteristics of PICV applied to the hydronic system were properly applied in the flow analysis. This result can be applied to PICV in the complex hydronic systems. Therefore, the optimal selection of PICV in hydronic system contribute the building energy saving.

A Methodology of Optimal Design for Solar Heating and Cooling System Using Simulation Tool

  • Lee, Dongkyu;Nam, Hyunmin;Lee, Byoungdoo
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.540-543
    • /
    • 2015
  • Solar energy is one of the most important alternative energy sources which have been shown to meet high levels of heating and cooling demands in buildings. However, the efficiencies to satisfy these demands using solar energy significantly vary based on the characteristics of individual building. Therefore, this paper is focused on developing the methodology which can help to design optimal solar system for heating and cooling to be in cooperated within the existing buildings according to their load profiles. This research has established the Solar Heating and Cooling (SHC) system which is composed of collectors, absorption chiller, boiler and heat storage tank. Each component of SHC system is analyzed and made by means of Modelica Language and Pistache tool is verified the results. Sequential approximate optimization (SAO) and meta-models determined to 15 design parameters to optimize SHC system. Finally, total coefficient of performance (COP) of the entire SHC system is improved approximately 7.3% points compared to total COP of the base model of the SHC system.

  • PDF