• Title/Summary/Keyword: Building Energy Efficiency

Search Result 736, Processing Time 0.023 seconds

Location Analysis on the Melting System of Waste FRP Ship (폐 FRP선박 용융처리시스템 입지 선정에 관한 연구)

  • Oh, S.W.;Jeon, T.B.;Park, J.M.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.75-82
    • /
    • 2010
  • The economical efficiency and easy ship building have enabled to spread FRP ships in the shipbuilding field. As waste FRP ships have been thrown away at a river or within a harbour, this matter has become issues. For the improvement of this matter, the melting technique and system of waste FRP ships was developed. But, Decision making was required for a location plan of the melting system of waste FRP ships. It's recognized that the location decision of this system is difficult due to the dependence on technical, economical, environmental factors. In this paper, we survey the primary factors of location-economic, life-environment, infrastructure and make up a question for the experts. We also calculate the important weight and related weight using Fuzzy AHP, Limiting probability method and discuss on the calculation results on the proposed sites.

Investigation and Analysis on the Surface Morphology of Roof-Top Photovoltaic System (평지붕 설치 태양광시스템의 표면형태 조사·분석)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.57-65
    • /
    • 2016
  • Domestic photovoltaic system for roof-top is installed towards the south at an angle of 20 to 35 degrees and the shape of PV array is divided into two kinds; a plane shape and a curved shape. This paper aims to understand an actual condition of PV facility and strengths and weaknesses of support structure production and installation and to consider the best PV surface shape by analyzing theoretical logics of these two surface shapes and architectural perspective-based realistic case studies. This study targeted 98 facilities including common houses, public institutions and education institutions. In common houses, all of 59 PV facilities have a plane surface. In public institutions, 7 of 15 PV facilities have a curved array surface and 8 PV facilities have a plane surface. In education institutions, also, 14 of 24 PV facilities have a plane array surface and 10 PV facilities have a curved surface. Most of 98 facilities have a flat roof supporting shape. However, it was found that the curved shape wasn't positive for PV generation due to the change of radial density and it was at least 10 % more expensive to produce its structure. Also, domestic general large single-plate PV facilities have problems of harmony with buildings and wind load. Therefore, it is considered that for fixed-type roof-top PV, a plane PV array shape is good for optimum generation and economic efficiency and a parallel array structure on the roof surface is favorable to wind load and snow load without being a hindrance to the building facade.

A Study on Environment-friendliness in the Chungnam Regional Public Hospitals - Focused on the Sustainable Site and Transportation (충남지역 지방공공의료원의 친환경성 분석 연구 - 토지이용 및 교통부분을 중심으로)

  • Lim, Yeonghwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.2
    • /
    • pp.37-45
    • /
    • 2014
  • Purpose: Numerous researches about healthcare buildings have been performed however, they were mainly focused on convenience or healing condition for medical treatments. The hospitals consume energy and generate $CO_2$ as twice as the residential or commercial buildings do(Lim, et al., 2010a:154). The public regional hospitals are especially in serious conditions. They are more than 20 years old in average. Energy efficiency and environmental friendliness in the public regional hospitals are far behind ones in private sectors. Even though the ministry of health & welfare is supporting renovation of the builidngs and enhancement of the facilities every year, it is not integrated including sustainibility. In this study, we investigates current conditions of the regional public hospital in envrionment-friendly standpoint, especially focused on Chungcheong Province area Hospitals. Methods: we investigates current conditions of the regional public hospital in envrionment-friendly standpoint, especially focused on Chungcheong Province area Hospitals. The study was executed by qualitative and quantitative evaluations with site inspection, drawing analysis and interviews. Results: Through this study, we found that the Chungnam regional public hospitals can be environmentally improved by management plans and programs. Implications: Based on this analysis, Korean Green Building Certification for healthcare facilities will be developed in near future.

An Environment-friendly Analysis of Hong-kong Environment-friendly Reuse Space (홍콩 친환경 재생공간의 친환경성 분석)

  • Kim, Sarah;Nam, Kyoung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.194-202
    • /
    • 2012
  • The purpose of this study is to extract environment-friendly planning elements to apply in Korea by putting together and reclassifying four foreign environment-friendly certification systems related to regeneration spaces - LEED in USA, CASBEE in Japan, BREEAM in England and BEAM in Hong Kong - and analyze and evaluate domestic and foreign spaces which were certified as Environment-friendly spaces in order to offer plan guidelines to raise awareness of the importance of environment-friendly elements in regeneration spaces and to encourage them. The concept and the characteristics of green building were studied through documentary survey. In addition, green certification system of the present domestic new spaces and foreign regeneration spaces was studied and assessment tools for indoor regenerated spaces-related green certification system were developed. With checklists which are developed in this study, level of going green of foreign spaces certified environment-friendly was assessed. Based on the results of this study, conclusions are as follows. As a result of case research of spaces-certified green of Hong-Kong's existing buildings with a developed checklist, application of general assessment part was all alike, but that of detailed assessment part was different. However, Hong Kong showed superiority in lighting energy saving, separate collection of recyclable domestic waste, recycling by-product and management. In addition, Hong Kong applied eco-friendly planning elements maintaining buildings in their condition as possible as it could with management, use of green program, replacement with high efficiency lighting, monitoring system, installation of recycling bins and energy saving by attaching reflective film.

  • PDF

Single Phase 5-level Inverter with DC-link Switches (DC링크 스위치를 갖는 단상 5레벨 인버터)

  • Choi, Young-Tae;Sun, Ho-Dong;Park, Min-Young;Kim, Heung-Geun;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.283-292
    • /
    • 2011
  • This paper proposed a new multi-level inverter topology based on a H-bridge with two switches and two diodes connected to the DC-link. The output voltage of the proposed topology is quite closer to a sinusoidal waveform compared with a typical single phase inverter. The proposed multi-level inverter is applicable to a power conditioning system for renewable energy sources, and it can be also used as a building block of a cascaded multi-level inverter for a high voltage application. In case of conventional H-bridge type or NPC type multi-level inverter, 8 controllable switches are used to obtain a 5 level output voltage, but the proposed multi-level inverter requires only 6 controllable switches. Thus the circuit configuration is quite simple, reliable and cost-effective implementation is possible. The efficiency can be improved owing to the reduction of the switching loss. A new PWM method based on POD modulation is suggested which requires only one carrier signal. The switching sequence to make the capacitor voltage balanced is also considered. The feasibility is studied through simulation and experiment.

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Analysis of Determinants of Carbon Dioxide Emissions in Korea: Considering Cross-sectional Dependence and Heterogeneous Coefficient (우리나라 이산화탄소 배출량 결정요인 분석: 횡단면 의존성과 계수 이질성을 고려하여)

  • Kim, So-youn;Ryu, Suyeol
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.400-410
    • /
    • 2021
  • This study analyzed the determinants of carbon dioxide emissions through the expanded STIRPAT model using panel data from 16 metropolitan cities and provinces in Korea from 2000 to 2019. After testing cross-sectional dependence and coefficient heterogeneity of panel data, we performed analysis using MG, CCEMG, and AMG estimation methods reflected these characteristics. The results of analysis using the AMG estimation method are as follows. The coefficients of income, population, and energy intensity were statistically significant with a positive sign, but urbanization was statistically insignificant. Reduction of carbon dioxide emissions in Korea can be achieved through an increase in energy efficiency and sustainable economic growth. It is necessary to establish a policy that can contribute to sustainable economic growth by inducing productivity improvement through technology innovation reducing carbon dioxide emissions in the long-term as well as building a low-carbon society through active development of carbon dioxide reduction technology.

Experimental Implementation of a Cableless Seismic Data Acquisition Module Using Arduino (아두이노를 활용한 무선 탄성파 자료취득 모듈 구현 실험)

  • Chanil Kim;Sangin Cho;Sukjoon Pyun
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.3
    • /
    • pp.103-113
    • /
    • 2023
  • In the oil and gas exploration market, various cableless seismic systems have been developed as an alternative to improve data acquisition efficiency. However, developing such equipment at a small scale for academic research is not available owing to highly priced commercial products. Fortunately, building and experimenting with open-source hardware enable the academic utilization of cableless seismic equipment with relatively low cost. This study aims to develop a cableless seismic acquisition module using Arduino. A cableless seismic system requires the combination of signal sensing, simple pre-processing, and data storage in a single device. A conventional geophone is used as the sensor that detects the seismic wave signal. In addition, it is connected to an Arduino circuit that plays a role in implementing the processing and storing module for the detected signals. Three main functions are implemented in the Arduino module: preprocessing, A/D conversion, and data storage. The developed single-channel module can acquire a common receiver gather from multiple source experiments.

A Plan for Establishing IOT-based Building Maintenance Platform (S-LCC): Focusing a Concept Model on the Function Configuration and Practical Use of Measurement Data (IOT 기반 건축물 유지관리 플랫폼 구축(S-LCC) 방안 : 기능구성과 계측 데이터 활용을 위한 개념 모델을 중심으로)

  • Park, Tae-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.611-618
    • /
    • 2020
  • The reliability of the results of LCC analysis is determined by accurate analytical procedures and energy data from which the uncertainty is removed. Until now, systems that can automatically measure these energy data and produce databases have not been commercialized. Therefore this paper proposes a concept model of an S-LCC platform that can automatically collect and analyze electric energy consumption data of equipment systems using the IOT, which is the core tool in the Fourth Industrial Revolution and operates the equipment system efficiently using the analyzed results. The proposed concept model was developed by the convergence of existing BLCS and IOT and was comprised of five modules: Facility Control Module, LCC Analysis Module, Energy Consumption Control Module, Efficiency Analysis Module, and Maintenance Standard Reestablishment Module. Using the results of LCC analysis deduced from this system, the deterioration condition of an equipment system can be identified in real-time. The results can be used as the baseline data to re-establish standards for the maintenance factor, replacement frequency, and lifetime of existing equipment, and establish new maintenance standards for new equipment. If the S-LCC platform is established, it would increase the reliability of LCC analysis, reduce the labor force for entering data and improve accuracy, and would also change disregarded data into big data with high potential.

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.