• Title/Summary/Keyword: Building Drag Effect

Search Result 16, Processing Time 0.024 seconds

Effects of Trees on Flow and Scalar Dispersion in an Urban Street Canyon (도시 협곡에서 수목이 흐름과 스칼라 물질 확산에 미치는 영향)

  • Kang, Geon;Kim, Jae-Jin
    • Atmosphere
    • /
    • v.25 no.4
    • /
    • pp.685-692
    • /
    • 2015
  • In this study, the effects of trees on flow and scalar dispersion in an urban street canyon were investigated using a computational fluid dynamics (CFD) model. For this, we implemented the drag terms of trees to the CFD model, and compared the CFD-simulated results to the wind-tunnel results. For comparison, we considered the same building configuration as the wind-tunnel experiment. The trees were located at the center of street canyon with the aspect ratio (defined as the ratio of the street width to the building height) of 1. First, the flow characteristics were analyzed in the tree-free and high-density tree cases and the results showed that the CFD model reproduced well the flow pattern of the wind-tunnel experiment and reflected the drag effect of trees in the street canyon. Then, the dispersion characteristics of scalar pollutants were investigated for the tree-free, low-density tree and medium-density tree cases. In the tree-free case, the nondimensionalized concentration distribution simulated by the CFD model was quite similar to that in the wind-tunnel experiment in magnitude and pattern. The correlation coefficients between the measured and simulated concentrations are more than 0.9 in all the cases. As the tree density increased, nondimensionalized concentration increased (decreased) near the wall of the upwind (downwind) building, which resulted from the decrease in wind speed case by the drag effect of trees. However, the CFD model underestimated (overestimated) the concentration near the wall of upwind (downwind) building.

Wind tunnel study of wind loading on rectangular louvered panels

  • Zuo, D.;Letchford, C.W.;Wayne, S.
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.449-463
    • /
    • 2011
  • Drag forces on a rectangular louvered panel, both as a free-standing structure and as a component in a generic low-rise building model, were obtained in a wind tunnel study. When tested in a building model, the porosity ratio of the wall opposite the louvered panel was varied to investigate its effect on the loading of the louvered panel. Both mean and pseudo-steady drag coefficients were obtained. Comparisons with the provisions for porous walls in contemporary loading standards indicate that for some opposite wall porosity ratios, the standards specify significantly different wind loads (larger and smaller) than obtained from this wind tunnel study.

The Effects of an Urban Renewal Plan on Detailed Air Flows in an Urban Area (도시 재개발이 도시 지역 상세 대기 흐름에 미치는 영향)

  • Lee, Ju-Hyun;Choi, Jae-Won;Kim, Jae-Jin;Suh, Yong-Cheol
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.69-81
    • /
    • 2009
  • Using a computational fluid dynamics (CFD) model, the effects of building complexes constructed under an urban renewal plan on air flows in an urban area were investigated. For this, the geographic information system (GIS) data were used as the input data of the CFD model and four experiments were numerically simulated for different inflow directions (westerly, southerly, easterly, and northerly cases). Before constructing building complexes under the urban renewal plan, wind speed at the pedestrian level was very low around buildings because of decrease in wind speed by the drag effect of the densely distributed low-rise buildings. As the high-rise buildings were constructed and building density decreased by the urban renewal plan, wind speed at the pedestrian level increased compared to that before the urban renewal plan because the drag effect by the buildings decreases and the channeling effect satisfying the mass continuity partially appeared at the spaces among the high-rise buildings. At the upper levels, wind speed partially increased inside the high-rise buildings due to the channeling effect but it remarkably decreased across a vast extent of the downwind regions due to the generation of the recirculation zone and the drag effect of the high-rise buildings.

  • PDF

Aerodynamic modification of setback distance at half height of the tall building to minimize the wind effect

  • Bairagi, Amlan Kumar;Dalui, Sujit Kumar
    • Wind and Structures
    • /
    • v.35 no.3
    • /
    • pp.193-211
    • /
    • 2022
  • The present study focuses on aerodynamic parameters behaviors and control on the single and double side setback building models at the buildings mid-height. The study is conducted by computational fluid dynamics (CFD) simulation. This study estimates the face wise pressure coefficient on single side setback buildings with a setback range of 20%-50% and double side setback buildings with setbacks ranging from 10%-25%. The polynomial fitted graphs from CFD data predict the Cp on different setback model faces within permissible limit ±13% error. The efficient model obtained according to the minimum drag, lift, and moment consideration for along and across wind conditions. The study guides the building tributary area doesn't control the drag, lift, and moment on setback type buildings. The setback distance takes a crucial role in that. The 20% double side setback model is highly efficient to regulate the moment for both along and across wind conditions. It reduces 17.5% compared to the 20% single side setback and 14% moment compared to the 10% double side setback models. The double side setback building is more efficient to control 4.2% moment than the single side setback building

Interference effects in a group of tall buildings closely arranged in an L- or T-shaped pattern

  • Zhao, J.G.;Lam, K.M.
    • Wind and Structures
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2008
  • Interference effects in five square tall buildings arranged in an L- or T-shaped pattern are investigated in the wind tunnel. Mean and fluctuating shear forces, overturning moments and torsional moment are measured on each building with a force balance mounted at its base. Results are obtained at two values of clear separation between adjacent buildings, at half and a quarter building breadth. It is found that strong interference effect exists on all member buildings, resulting in significant modifications of wind loads as compared with the isolated single building case. Sheltering effect is observed on wind loads acting along the direction of an arm of the "L" or "T" on the inner buildings. However, increase in these wind loads from the isolated single building case is found on the most upwind edge building in the arm when wind blows at a slight oblique angle to the arm. The corner formed by two arms of buildings results in some wind catchment effect leading to increased wind pressure on windward building faces. Interesting interference phenomena such as negative drag force are reported. Interference effects on wind load fluctuations, load spectra and dynamic building responses are also studied and discussed.

Experimental Investigation of the Drag Coefficient of Porous Road Signs (유공형 도로표지의 항력계수에 대한 실험적 연구)

  • Sung, Hongki;Chong, Kyusoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.71-76
    • /
    • 2018
  • Recently, various technologies have been developed for road facilities to reduce the load, some of which use technologies employing perforated plates for wind load reduction. Currently, there are no regulations concerning the drag coefficient of perforated plates for domestic road facilities. In the United States, the regulations regarding the drag coefficient of perforated plates in the 'Minimum design loads for buildings and other structures' were revised based on the studies of Letchford (2001) and Giannoulis (2012). In this study, a wind tunnel test was carried out to analyze the feasibility of applying regulations involving the perforated plates' drag coefficient. The results of the wind tunnel test and the drag coefficient used in the regulation were compared and analyzed. In addition, the reduction effect of the cross area of road signs calculated by applying the drag coefficient was analyzed. The results of the wind tunnel test and the value of the drag coefficient used in the regulation in the US were found to be very similar. Therefore, it was found that it is possible to apply the formula involving the drag coefficient of the perforated plate to the regulation and that the cross area of the perforated plate used for the post of the road sign is reduced by about 9.45% and that of the horizontal post by about 6.45%.

Large eddy simulation of flow over a wooded building complex

  • Rehm, R.G.;McGrattan, K.B.;Baum, H.R.
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.291-300
    • /
    • 2002
  • An efficient large eddy simulation algorithm is used to compute surface pressure distributions on an eleven story (target) building on the NIST campus. Local meteorology, neighboring buildings, topography and large vegetation (trees) all play an important part in determining the flows and therefore the pressures experienced by the target. The wind profile imposed at the upstream surface of the computational domain follows a power law with an exponent representing a suburban terrain. This profile accounts for the flow retardation due to friction from the surface of the earth, but does not include fluctuations that would naturally occur in this flow. The effect of neighboring buildings on the time dependent surface pressures experienced by the target is examined. Comparison of the pressure fluctuations on the single target building alone with those on the target building in situ show that, owing to vortices shed by the upstream buildings, fluctuations are larger when such buildings are present. Even when buildings are lateral to or behind the target, the pressure disturbances generate significantly different flows around this building. A simple grid-free mathematical model of a tree is presented in which the trunk and the branches are each represented by a collection of spherical particles strung together like beads on a string. The drag from the tree, determined as the sum of the drags of the component particles, produces an oscillatory, spreading wake of slower fluid, suggesting that the behavior of trees as wind breakers can be modeled usefully.

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

Numerical Simulation on Laminar Flow past a Rotating Circular Cylinder (회전하는 원형 실린더 주위 층류유동장의 수치 시뮬레이션)

  • Park, Jong-Chun;Moon, Jin-Kook;Yoon, Hyun-Sik;Lee, Byung-Hyuk;Chun, Ho-Hwan;Suh, Sung-Bu
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.1-10
    • /
    • 2005
  • The effect of rotation on the unsteady laminar flaw past a circular cylinder is numerically investigated in the present study. The numerical solutions for the 2D Navier-Stokes equation obtained, using two different numerical methods. One is an accurate spectral method and the other is a finite volume method(FVM). First, the flaw around a stationary circular cylinder is investigated to understand the basic phenomenon of flaw separation and bluff body wake. Next, the flow characteristics of the laminar flow, past a rotating circular cylinder, are investigated, using a FVM developed in this study. By the effect of rotation, it is seen that values of lift increase, while the values of mean drag decrease. Further, the criteria of angular velocity, at which the Karman vorteces disappear, is also determined.

Effect of Pitch Angle and Blade Length on an Axial Flow Fan Performance (피치각과 날개 길이에 따른 축류팬의 성능)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • In this study, the performance of an impeller according to blade length and pitch angle was studied experimentally by building a variable pitch impeller while changing blade length to review the effect of blade length and pitch angle on a fan's performance. The pitch angle was changed in six steps from $20^{\circ}{\sim}45^{\circ}$ at intervals of $5^{\circ}$ while the blade lengths were changed to 90 mm, 100 mm, 110 mm and 120 mm with an identical airfoil shape while carrying out the experiment. The results are summarized as follows: The air flow per static pressure of axial fans increased linearly with increase of pitch angle, but the high static pressure showed a decrease at a pitch angle of $35^{\circ}$. The shaft power increased proportionally to the pitch angle at all blade lengths; the larger the pitch angle, the larger the measured increase of shaft power. This is because the drag at the fan's front increases with the pitch angle. In the axial fans considered in this research, the flow and increase of static pressure amount increased up to a pitch angle of $30^{\circ}$ but decreased rapidly above $35^{\circ}$.