• Title/Summary/Keyword: Building Background

Search Result 538, Processing Time 0.025 seconds

Architectural Characteristics of Pinson Hall, Yonsei University, focused on Usage as University Dormitory from 1922 to 1944 (연세대학교 핀슨홀(Pinson Hall)의 건축적 특징 -1922년~1944년 기숙사로의 사용을 중심으로-)

  • Kim, Ki-Joo;Lee, Yeon-Kyung
    • Journal of architectural history
    • /
    • v.28 no.3
    • /
    • pp.55-66
    • /
    • 2019
  • Pinson Hall is a dormitory building of Chosen Christian College, built in 1922, and it still remains comparatively well preserved as original form. This building is worthy in that it shows the living space of western style college in Korea, as well as characteristics of collegiate gothic style and building technology, designed by western architect in 1920s. At first, based on literate review and field survey, this study aims to trace the construction background and process of Pinson Hall, and find out its architectural characteristics with the original form when it is used as dormitory. Additionally, it deals with historic meaning and value of Pinson Hall as a modern western style college dormitory, through comparison with other dormitories in the same era. In conclusion, Pinson Hall is a Western style dormitory which allows students to accustom themselves to Western life style, using bed and desk, as well as it shows the new building technology in the early 1920s which has mixture of masonry and reinforced concrete structure.

Wind tunnel study on fluctuating internal pressure of open building induced by tangential flow

  • Chen, Sheng;Huang, Peng;Flay, Richard G.J.
    • Wind and Structures
    • /
    • v.32 no.2
    • /
    • pp.105-114
    • /
    • 2021
  • This paper describes a wind tunnel test on a 1:25 scale model of TTU building with several adjustable openings in order to comprehensively study the characteristics of fluctuating internal pressures, especially the phenomenon of the increase in fluctuating internal pressures induced by tangential flow over building openings and the mechanism causing that. The effects of several factors, such as wind angle, turbulence intensity, opening location, opening size, opening shape and background porosity on the fluctuating internal pressures at oblique wind angles are also described. It has been found that there is a large increase in the fluctuating internal pressures at certain oblique wind angles (typically around 60° to 80°). These fluctuations are greater than those produced by the flow normal to the opening when the turbulence intensity is low. It is demonstrated that the internal pressure resonances induced by the external pressure fluctuations emanating from flapping shear layers on the sidewall downstream of the windward corner are responsible for the increase in the fluctuating internal pressures. Furthermore, the test results show that apart from the opening shape, all the other factors influence the fluctuating internal pressures and the internal pressure resonances at oblique wind angles to varying degrees.

A Methodology to Determine Composite Material Allowables and Design Values Using Building Block Approach (빌딩블록 접근법을 이용한 복합재 재료 허용치 및 설계치 설정 방법)

  • Kim, Sung Joon;Lee, Seung-gyu;Hwang, In-hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.6
    • /
    • pp.377-384
    • /
    • 2022
  • In the design of composite aircraft structures, it is very important to set material allowables and design values, which take into account certification. And when determining the material allowable and design value of composite structures, the static strength, damage tolerance requirements, and environmental effects should be considered. The building block approach has been applied to the civil and military aviation industry for a long time and provides the principal certification methodology. This current certification methodology is based on extensive testing including coupon, element, sub-component, and full scale test. In this paper, some examples of composite allowable tests have been presented and the fundamental background and application methods of the building block approach have been presented.

A Study on the Characteristics of Campidoglio Hill Plan by Michelangelo (미켈란젤로의 캄피돌리오 언덕계획의 특성에 관한 연구)

  • Kim, Seok-Man
    • Journal of architectural history
    • /
    • v.18 no.6
    • /
    • pp.85-101
    • /
    • 2009
  • The Purpose of this paper is a study on the characteristics of Campidoglio hill plan by Michelangelo. 1. The plan of the Campidoglio hill is composed of the harmonized and united space, in spite of the existing conditions of a steep flight of land, a irregular site shape, a building of each other different dimension and form. And it is newly changed by site left through the modification of existing building elevation, utilization of existing building for new planning, connection with existing building and newly planned building from plaza composition of trapezoid form. 2. The concept of planning of the Campidoglio hill is planned by compromising for requirements of Baroque after Renaissance which urban planning characteristics of Baroque is as the relation with urban street through a inclined stairs and process such as street-approach stairs-plaza-symbol of inside plaza-building. 3. The section plan of the Campidoglio hill is planned by which can be easily approached to the plaza through the inclined stairs of gentle angle from street at the center east-west direction of main axis such as main axis, utilizing the existing site shape, and it is composed of the convex shape ascending gently at the center central part of the plaza. 4. The plan of the Campidoglio hill is composed of the elation with the axis of existing Senatorio palace, building planning of perfect balance, plaza composition of reversed trapezoid form bybuilding planning, central concentrated planning of buildings surrounding plaza. 5. The three palace of the plan of the Campidoglio hill is composed of the concept as theater which the stage background forms the front elevation of Senatorio palace higher two palace and the wings of either side of stage form the front elevation of Conservatori palace and Nuovo palace, surrounding three palace elevation around plaza of trapezoid form.

  • PDF

Relationship between intra-household food distribution and coexistence of dual forms of malnutrition

  • Wibowo, Yulianti;Sutrisna, Bambang;Hardinsyah, Hardinsyah;Djuwita, Ratna;Mondastri, Korib M.;Syafiq, Ahmad;Tilden, Atmarita;Najib, Mardiati
    • Nutrition Research and Practice
    • /
    • v.9 no.2
    • /
    • pp.174-179
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: The relationship between food intake and nutritional status has been clearly established. Yet, there are only limited studies on food intake among family members and their nutritional status. The study examined the relationship between intra-household food distribution and coexistence of dual forms of malnutrition (DFM) in the same household. SUBJECTS/METHODS: Households with a malnourished child and overweight mother were categorized as DFM. Intra-household food distribution among family members was reported using ratios, which are a measure of individual intakes as compared to all household member intakes adjusted to RDA. RESULTS: A1,899 families were included in the study. The prevalence of DFM was 29.8% (95%CI 26.5-31.2). Children consumed lower amounts of energy (OR 1.34; 95%CI 1.06-1.69, P = 0.011), carbohydrates (OR 1.2; 95%CI1.03-1.61, P = 0.022), protein (OR 1.3; 95%CI 1.03-1.64, P = 0.026), and fat (OR 1.3; 95%CI 1.05-1.66, P = 0.016) than their mothers and other family members. In contrast, mothers consumed more carbohydrates than children and other family members (OR1.24; 95%CI 1.02-1.51, P = 0.03). CONCLUSIONS: This study is the first to report on the food distribution among family members and its relationship with occurrence of DFM in Indonesia. The results confirm the occurrence of an unequal food distribution between children and mothers, which increases risk of DFM in the household. The results also demonstrate that nutritional education at the household level is important to increase awareness of the impact of DFM.

A Study on Potential of Engineered Wood for 9-story Office Buildings (공학목재의 9층 사무소 건물 적용 가능성 연구)

  • Chu, Yurim;Kim, Taewan;Kim, Seung-Rae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.163-170
    • /
    • 2017
  • The need for eco-friendly building materials such as engineered wood has increased to reduce carbon emissions. Although the range and height of engineered wood buildings are gradually increasing in North America and Europe, engineered wood is mainly used for low-rise residential buildings in Korea. In order to reduce carbon emissions more, therefore, it needs to expand the use of engineered wood by applying it to various buildings with different uses or more stories. With this background, the aim of this study is to investigate the applicability of engineered wood for 9-story office buildings. Since a 9-story building with engineered wood only is not allowed in KBC, an example building has RC ordinary shear walls as the lateral force resisting system while engineered wood is only used for gravity load resisting moment frames. Another example building is also used for comparison where both lateral and gravity load resisting systems are designed by RC. The applicability of engineered wood is investigated by comparing the seismic performance and the amount of carbon emission of both buildings. The result shows that the seismic performance of both buildings was not significantly different while the amount of carbon emission of the engineered wood building was much less then the RC building. Based on this result, engineered wood is sufficiently applicable to 9-story office buildings even though it still needs to pay attention to the shear design of reinforce concrete walls.

Ergonomics Job Hazard Evaluation of Building Cleaners

  • Lee, Kyung-Sun;Lee, In-Seok;Kim, Hyun-Joo;Jung-Choi, KyungHee;Bahk, Jin-Wook;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.427-435
    • /
    • 2011
  • Objective: The objective of this study was to evaluate a work of building cleaners using the ergonomic methods. Background: Previous studies about cleaning worker describe typical physical demands of this work. They found that the most significant risk factors associated with the physical work of cleaners are static loads and repetitive movements and high output of force. Method: A head of ergonomics estimation was work analysis(define of combined task, work tool, work time and frequency of combined task) and posture analysis of worker. Results: The results showed that combined task of building cleaners was classification sweeping, mopping(wet), mopping(oil), moving barrels/carts, dumping trash bags, scrubbing, arrangement of cleaning tool, arrangement of circumferential, moving of cleaning tool, and waiting. The work time of combined task such as mopping(wet) and scrubbing indicated high ratio. The posture analysis of building cleaners indicated high value in bending of the head, lower arm, and hands. Conclusion: The findings appear to indicate that building cleaner were related to high risk of work-related musculoskeletal disorders. So, building cleaner would be required an interventional strategy, improvement of cleaning tools and working environment. Application: If ergonomics rule can be integrated into existing cleaning tools and work environments, the risk of occupational injuries will be reduced.

Evaluation of the Radon Contribution Rate in Apartments through Evaluation of the Radon Exhalation Rate from Building Materials (건축자재 라돈 방출률 평가를 통한 공동주택 내 라돈 기여율 평가)

  • Hong, Hyungjin;Choi, Jiwon;Yoon, Sungwon;Kim, Heechun;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.425-431
    • /
    • 2021
  • Background: This study evaluated the radon contribution rate through an evaluation of the exhalation rate of radon from building materials. Objectives: This study compared and evaluated the computation of the radon contribution rate based on each different exhalation rate in a building. Methods: The six demonstration houses that are the subject of this study are wall structures or Rahmen structures, and include demonstration houses similar to general residential environments and non-finishing houses with some walls exposed. Results: The highest exhalation rate was found at 62.98 Bq/m2 per day from the non-finishing floor, and the second highest exhalation rate was from stone materials at 58.76 Bq/m2 per day. Based on this result, investigating the contribution rate of building materials derived from building materials among indoor radon concentrations, house three was the highest at 81.7%, and house one was confirmed to be 33.96%. Conclusions: It can be judged that the effect of exposed concrete and stone is high, and that it is possible to reduce radon emitted from indoor building structures by controlling the indoor materials.

Case Study on Sustainable office space of the LEED Green Building in the United States - Focused on the Materials and Resources of Indoor Evaluation Factors - (미국 내 LEED 그린빌딩의 지속가능한 업무공간 사례 연구 - 실내 평가요소 중 재료 및 자원을 중심으로 -)

  • Ha, Sook-Nyung;Han, Young-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.176-185
    • /
    • 2013
  • (Background)In modern industrial society, the design industry failed to observe the law of nature, destructing it. Regardless its intention, the design industry destructed the environment so that it can't maintain the future life because of waste and disaster. For the purpose, it is important to adopt the technology to reuse the waste resource generated by building or minimize the damage to environment for the resource that can't be recycled. (Methods)On the assumption that the material and resource can be an alternative plan for the design that can make environment be sustained, the study analyzed materials and resources out of superior office space of USA, which were selected by LEED Green Building Rating System. (Results)The analysis result revealed that all cases reused main structural part of existing building and indoor and various materials were reused or recycled. Especially, the materials without or with low amount of VOCs and formaldehyde were used. In order to reduce construction waste, the finish of existing building was exposed as it was, 50% of reused materials were used or disassemblable materials were used. When regional materials are used, there is an advantage to reduce transportation cost and recycle the materials rapidly. Lastly, the environment-friendly certified by FSC was used in all cases. (Conclusion)After all, the material is one of the space design strategies sensitive to environment so it is important to select good material. Harmless, environment-friendly materials applied to sustainable office space contribute to the creation of healthy environment. In addition, the use of recycled materials and reused materials to minimize waste is also essential factor for creating sustainable space.

A study on the chemical emission of furnitures using the large chamber method (대형챔버에 의한 생활제품(가구류) 방출오염물질 특성연구)

  • Park, Jae-Hyoung;Knag, Yoon-Kyung;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.742-747
    • /
    • 2008
  • Formaldehyde(HCHO) and total volatile organic compounds(VOCs) can cause adverse health effects to the building occupants and may contribute to symptoms of 'Sick Building Syndrome'. These chemical contaminants are emitted from furnishings and electronic equipments as well as building materials. The purpose of this study is to measure and analyze VOCs and HCHO emission concentration from furnitures composed of wood materials including various chemicals by the large chamber method. This paper presents experiment results on the emission concentration of TVOCs and HCHO released from furnitures, such as bed, kitchen, sofa and table by a large chamber($24m^3$). The temperature and air humidity in the chamber are controlled to $25{\pm}1{\circ}C$ and $50{\pm}5%$ for this experiment. When the air change rate is $0.5hr^{-1}$, the background concentrations within the large chamber are below $50{\mu}g/m^3$ for TVOC, $5{\mu}g/m^3$ for HCHO and individual VOCs. The study is investigated the characterization of the chemical emission TVOC and HCHO concentrations and unknown VOCs from 6 furnitures.

  • PDF