• Title/Summary/Keyword: Buffer area

Search Result 525, Processing Time 0.023 seconds

Hybrid Buffer Replacement Scheme Considering Reference Pattern in Multimedia Storage Systems (멀티미디어 저장 시스템에서 참조 유형을 고려한 혼성 버퍼 교체 기법)

  • 류연승
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.1
    • /
    • pp.47-56
    • /
    • 2002
  • Previous buffer cache schemes for multimedia storage systems only exploited the sequential references of multimedia files and didn't consider looping references. However, in some video applications like foreign language learning, users mark the scene as loop area and then application automatically playbacks the scene several times. In this paper, we propose a new buffer replacement scheme, called HBM(Hybrid Buffer Management), for multimedia storage systems that have both sequential and looping references. Proposed scheme assumes that application layer informs reference pattern of files to file system. Then HBM applies an appropriate replacement policy to each file. Our simulation experiments show that HBM outperforms previous buffer cache schemes such as DISTANCE and LRU.

  • PDF

Modeling and simulation for Network Data Access System (초고속 통신망 중간 접속 장치의 모델 개발과 버퍼 용량 결정을 위한 시뮬레이션)

  • Jun, Jong-Arm;Kang, Hoon;Kim, Tae-Gap;Park, Hyun-Dong;Ryou, Jae-Cheol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.8
    • /
    • pp.2106-2119
    • /
    • 1997
  • NDAS(Network Data Access System) is a system that interconnects high speed network(B-ISDN) and Local Area Network(Ethernet, FDDI). Nowadays, the request of multimedia data increases rapidly, so NDAS system must accept and process that request efficiently. Comparing with normal data traffic characteristics, multimedia data traffic characteristics are much complex, so it is necessary to implement the system that can cover such factor. In this paper, we suggest a NDAS hardware system model and also we propose a proper buffer size of NDAS system through the simulation. For measuring the proper buffer size of NDAS, we assumed two different simulation models, one is the case of using only one buffer and the other is the case of using two different buffers for Ethernet and FDDI, respectively. After comparing and analyzing simulation results, we suggest the proper NDAS system buffer size.

  • PDF

Analysis on Effects Area of Subway Station Using GIS and RS (GIS와 RS를 이용한 전철역의 영향권 분석)

  • Yang, In-Tae;Kim, Jae-Cheol;Chun, Ki-Sun;Park, Jai-Kook
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.93-100
    • /
    • 2003
  • Population concentration phenomenon of city needs large-scale ride, and It is important elements that develop the circumference but, it is difficult to evaluate effects that ride gets land utilization change. Therefore, this research evaluates change and effect of land utilization as political to subway station that is main ride of Seoul City, and chose standard and position for right place arrangement of electric railway station. Research contents analyzed subway station effect area interior and external land utilization change taking advantage of GIS's buffer function and RS's classification technique, and decide precedence at subway station establishment and chose position of subway station for effect area outside area.

  • PDF

A Study on Problems of Combined Development and Environment-Friendly Improvements of Golf Course in Forest Areas in Gyeonggi-Do (경기도 산림지역 골프장의 연접개발 문제점 및 친환경성 개선방안)

  • Hwang, So-Young;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.3
    • /
    • pp.143-155
    • /
    • 2011
  • Recently, in forest areas of Gyeonggi-Do where golf courses are developed indiscriminately due to the rapid increase in demand, two and three golf courses are being concentrated and combined to develop and it's occurring lots of problems. This study therefore, aims to examine their problems and propose environment-friendly improvements of combined development, by analyzing laws related to golf course's location and the current location status. The results of this study are as followings; Firstly, when analyzing related laws, it was found that unified standards should be established in relation to regulation of the external conditions of golf course sites and individual index. Secondly, standards of a proper separated distance are needed, when developing golf courses. Thirdly, we need to preferentially preserve areas where should be protected environmentally, and establish criteria approving golf courses built close to the boundary of a buffer area only, by introducing the concepts of a buffer area based on the UNESCO MAB. Lastly, we have to set up criteria considering Network elements for maintaining the connectivity of the ecosystem.

A Study on Vegetation Index for Zoning of Natural Ecosystem on Baekdudaegan -From Namdeogyusan to Sosagogae- (백두대간 자연생태계의 지역구분을 위한 식생지수에 관한 연구 -남덕유산 -소사고개 구간-)

  • 김갑태;엄태원
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.2
    • /
    • pp.158-166
    • /
    • 2004
  • For the zoning of natural ecosystem, Vegetation Index is calculated from the vegetation data surveyed on Baekdudaegan (from Namdeogyusan to Sosagogae). Five factors-biodiversity, conservation value of the stand, environmental quality, longevity of the stand, site productivity- are considered in the calculation of Vegetation Index. Vegetation Index might be a useful zoning tool for management of Baekdudaegan. For Vegetation Index I, 8 sample plots 12.l% of total 66 sample plots are belong to core area, 21 sample plots 31.8% and 37 sample plots 56.l% are belong to buffer zone and transition area, respectively. For Vegetation Index II, 37 sample plots 41.9% of total 60 sample plots are belong to core area, 19 sample plots 28.8% and 19 sample plots 28.8% are belong to buffer zone and transition area, respectively.

Superconducting properties of SiC-buffered-MgB2 tapes

  • Putri, W.B.K.;Kang, B.;Duong, P.V.;Kang, W.N.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.1-4
    • /
    • 2015
  • Production of $MgB_2$ film on metallic Hastelloy with SiC as the buffer layer was achieved by means of hybrid physical-chemical vapor deposition technique, whereas SiC buffer layers with varied thickness of 170 and 250 nm were fabricated inside a pulsed laser deposition chamber. Superconducting transition temperature and critical current density were verified by transport and magnetic measurement, respectively. With SiC buffer layer, the reduced delaminated area at the interface of $MgB_2$-Hastelloy and the slightly increased $T_c$ of $MgB_2$ tapes were clearly noticed. It was found that the upper critical field, the irreversibility field and the critical current density were reduced when $MgB_2$ tapes were buffered with SiC buffer layer. Clarifying the mechanism of SiC buffer layer in $MgB_2$ tape in affecting the superconducting properties is considerably important for practical applications.

High Speed Non-Inverting SOI Buffer Circuit by Adopting Dynamic Threshold Control (동적 문턱전압 제어 기법을 이용한 고속 비반전 SOI 버퍼 회로)

  • 이종호;박영준
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.28-36
    • /
    • 1998
  • We have proposed a new non-inverting SOI buffer circuit for the high speed operation at low supply voltage. The body biases of main MOS devices in the proposed circuit are controlled dynamically via subsidiary MOS device connected efficiently to the body terminal. We showed current derivability of the body controlled devices obtained by device simulation and compared with that of conventional SOI devices. Delay time characteristics of the buffer circuit were analyzed by SPICE simulation and compared with those of conventional SOI CMOS buffer circuits. Delay time reduction of the SOI buffer over conventional SOI CMOS buffer with same area is about 36 % at $V_{S}$=1.2 V and $C_{L}$=2 pF. pF.

  • PDF

Demonstration of Heat Dissipation Performance of Copper Plate in Engineered Barrier System

  • Minsoo Lee;Jin-Seop Kim;Min-Seop Kim;Seok Yoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.22 no.2
    • /
    • pp.105-115
    • /
    • 2024
  • In this study, we employed a small-scale experiment to demonstrate the introduction of a thin copper heat dissipation plate into a bentonite buffer layer of an engineered barrier system. This experiment designed for spent nuclear fuel disposal can effectively reduce the maximum temperature of the bentonite buffer layer, and ultimately, make it possible to reduce the area of the disposal site. For the experiment, a small-scale engineered barrier system with a copper heat dissipation plate was designed and manufactured. the thickness of the cylindrical buffer was about 2 cm, which was about 1/20 of KAERI Repository System (KRS). At a power supply of 250 W, the maximum buffer temperature reduced to a mere 1.8℃ when the thin copper plate was introduced. However, the maximum surface temperature reduced to a remarkable 9.1℃, when a U-collar copper plate was introduced, which had a good contact with the other barrier layers. Consequently, we conclude that the introduction of the thin copper plate into the engineered barrier system for spent nuclear fuel disposal can effectively reduce the maximum buffer temperature in high-level radioactive waste disposal repositories.

A Value Analysis of the Hedgerow in Cultivated Areas in point of Landscape (농경지 내 띠형수림의 경관적 가치분석)

  • Cho, Hyun-Ju;Ryu, Yeon-Su;Lee, Hyun-Taek;Ra, Jung-Hwa
    • Current Research on Agriculture and Life Sciences
    • /
    • v.27
    • /
    • pp.69-75
    • /
    • 2009
  • This research regard it as most meaningful to realize the importance of the hedgerow in cultivated areas functioning as a residual landscape element in rural landscape and set improvement guidelines through landscape character and value analysis to cope with landscape malfunction. The results of summary are as follows. 1) First of all, as a result of landscape character analysis of edge stripe in cultivated land in total of 7 case areas, for example, the edge stripe in cultivated land in case area 4 and 8 maintain the width of 10m and are assessed satisfactory in terms of vegetation development condition, appearance of living species, connectivity, buffer capacity and so on. Also, as a result of structural character of correlation analysis among items, the correlation coefficient between width and appearance of living species showed 0.941, the highest. Following are connectivity and appearance of living species and width and buffer capacity respectively: 0.841 and 0.740. 2) As a result of landscape character analysis of uncultivated stripe in total of 6 case areas, it is analyzed that case area 4 maintains the widest width as almost 4.5m average width and considered valuable as I degree in vegetation development condition, filtering, and connectivity. 3) As a result of problem analysis of uncultivated stripe, for example, case 3, 9, and 10 was analyzed that the width was below 1.25m which is too small to carry out the function of buffer and habitat for living creature, so minimum standard width was set between 4~5m through comprehensive analysis of character of each case area. Based on the result above landscape character, value and problem analysis, main improvement guidelines are set in terms of width, connectivity, filtering, and vegetation development, restrictive practices and so on.

  • PDF

A Study on Establishment of Buffer Zone of Radioactive Waste Repository (방사성패기물 처분시설에서의 완충공간 설정에 대한 고찰)

  • Yoon, Jeong-Hyoun;Park, Joo-Wan;Ju, Min-Su;Kim, Chang-Lak;Park, Jin-Baek
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • A new proposed repository has a final capacity of 800,000 drums radioactive waste. Most of foreign repositories have a general practice of segregating control zones which mainly contributes to classification of degree of control, whether it is called buffer zone or not. Domestic regulatory requirements of establishment of buffer zone in a repository are not much different from those of nuclear power plants for operation period, in which satisfactory design objective or performance objective is the most important factor in determination of the buffer zone. The meaning of buffer zone after closure is a minimum requested area which can prevent inadvertant intruders from leading to non-allowable exposure during institutional control period. Safety assessment with drinking well scenario giving rise to the highest probability of exposure among the intruder's actions can verify fulfillment of the buffer zone which is determined by operational safety of the repository. At present. for the repository to be constructed in a few years, the same procedure and concept as described in this paper are applied that can satisfy regulatory requirements and radiological safety as well. However, the capacity of the repository will be stepwise extended upto 800,000 drums, consequently its layout will be varied too. Timely considerations will be necessary for current boundary of the buffer zone which has been established on the basis of 100,000 drums disposal.

  • PDF